Identifying System Power Requirements
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
D-8
HiPath 3000/5000 V9, Service documentation
power_calc.fm
HiPath 3500 Board Power Requirement
D.4
HiPath 3500 Board Power Requirement
Table D-7
Nominal Output of the HiPath 3500 Power Supply Units
Power Supply Unit
Part Number
Max. Nominal Output in W
5 V
–48 V
S30122-K7373-A900
S30122-K7373-M900
40.0
53.0
S30177-U773-X with
S30122-K7686-M1
–
110
>
You must check whether the total power requirement of the boards used and the
workpoint clients connected exceeds the maximum possible output of the UPSC-DR
with or without Powerbox PB3000. Section D.7 contains a sample calculation.
Table D-8
HiPath 3500 Board Power Requirement
Board or Component
Part Number
Net Power Requirement in
W
5 V
–48 V
S30807-H5482-X
–
2.0
S30807-H5485-X
–
3.0
(including subboards) S30810-Q2935-Z301
7.0
0.5
S30810-K2943-Z 10.0
–
S30122-K7379-Z
2.6
0.3
Fan for HiPath 3500
–
–
1.4
DM1
S30807-Q5692-X100
–
5.0
S30810-K2956-X300
2.0
1.0
S30817-K922-Z301
0.8
–
S30817-K924-Z313
1.0
–
S30817-Q932-Z
0.5
–
CASR-2
S30810-K2945-X
4.5
–
S30817-Q923-Zxxx
0.2
–
S30810-K2918-Z
5.7
1
0.1
S30810-K2919-Z
0.8
–
Summary of Contents for HiPath 3000 Series
Page 1252: ......