When the PSO 1 RX1 Wrap Used is set to
Yes
, the PSO 1 RX1 Wrap is available in the
System
Inputs
and can be assigned to a vital input or set via internal logic. The Wrap Pickup Delay
described in Section 5 will be applied to the input.
An external track circuit can be used in place of the internal PSO by setting RX1 Used to
External as shown in Figure 10-18.
Figure 10-18 External PSO Receiver
10.1.3.4 PSO ‘N’ Rx1 and 2 Codes
Figure 10-19 PSO Codes shows the PSO Receiver Code menu for Receiver 1 (Receiver 2 is
similar). This is used to select which code the receiver can accept. This menu is only available
when the internal PSO receiver is used.
•
Rx1 Code A Valid
: range Yes, No, default Yes
•
RX1 Code A Drop Delay
: range 0 – 99 sec, default 0 sec
•
Rx1 Code C Valid
: range Yes, No, default No
•
RX1 Code C Drop Delay
: range 0 – 99 sec, default 0 sec
•
Rx1 Code D Valid
: range Yes, No, default No
•
RX1 Code D Drop Delay
: range 0 – 99 sec, default 0 sec
•
Rx1 Code E Valid
: range Yes, No, default No
•
RX1 Code E Drop Delay
: range 0 – 99 sec, default 0 sec
•
Rx1 Code F Valid
: range Yes, No, default No
•
RX1 Code F Drop Delay
: range 0 – 99 sec, default 0 sec