s

Handle and Shield  
Replacement kit.

Installation Instructions /  Instructivo de Instalación

Use only with Siemens certified Components.
Utilizar únicamente con componentes certificados por Siemens.
A utiliser uniquement avec les composants certifiés Siemens.

Item:     FDHANDLE

Turn off and lock out all power supplying this device before 
working on this device.
Replace all covers and close the enclosure door before 
power supplying this device is turned on.

Couper l'alimentation de l'appareil et barrer avant de 
travailler.
Remplacez touts les couverts avant que
l'approvisionnement de pouvoir soit alimenté.

Tensión peligrosa.
Puede causar la muerte o lesiones graves.

Tension dangereuse.
Danger de mort ou risque de blessures graves.

Hazardous Voltage
Will cause death or serious injury

Desenergice totalmente antes de instalar o darle servicio. 
Reemplace todas las barreras y cubiertas antes de 
energizar el interruptor.

For use with Types:

Circuit Breakers: FXD6-A, FD6-A, HFXD6, HFD6, 
HHFD6, HHFXD6, FFC, FFF and CFD6.
Motor Circuit Interrupters:FXD6ETI, CFD6ETI 
Molded Case Switches : FXD6,FXD6-A, CFD6

NOTE - These instructions do not purport to cover

all details or variations in equipment, or to provide

for every possible contingency to be met in

connection with installation, operation or maintenance.

Should further information be desired or

should particular problems arise, which are not

covered sufficiently for the purchaser’s purposes,

the matter should be referred to the local Siemens

sales office. The contents of this instruction

manual shall not become part of or modify any

prior or existing agreement, commitment or

relationship. The sales contract contains the entire

obligation of Siemens. The warranty contained in

the contract between the parties is the sole

warranty of Siemens. Any statements contained

herein do not create new warranties or modify the

existing warranty. 

Trademarks - Unless otherwise noted, all names

identified by ® are registered trademarks of

Siemens AG or Siemens Industry, Inc.

The remaining trademarks in this publication may

be trademarks whose use by third parties for their

own purposes could violate the rights of the owner.

1 / 5

I.L. No. 810519A00

For Use With: Frame FD, FM

Para Usar Con Caja Base: FD, FM

Cal. ISO 6789

8 1 0 5 1 9 A 0 0

Released Production, 0P v5, Apr 26, 2011

Summary of Contents for FDHANDLE

Page 1: ...FD6ETI Molded Case Switches FXD6 FXD6 A CFD6 NOTE These instructions do not purport to cover all details or variations in equipment or to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should ...

Page 2: ...s de instalar o darle servicio Reemplace todas las barreras y cubiertas antes de energizar el interruptor 2 5 I L No 810519A00 2 Remove and retain Cover Screws Circuit Breaker or Motor Circuit Interrupter ETI d Tripped Press red Push to Trip button c b OFF O Molded Case Switch 1 Prepare device for handle replacement Turn OFF and lock out all power supplying this device before working on this devic...

Page 3: ...All broken pieces must be retrieved from this device Do not continue use of device if all pieces are not retrieved Handle Shield Use clean cloth to thoroughly clean the area indicated WARNING Adding lubrication may result in damage to the handle shield Do not use lubrication on handle shield Notice Molded Case Switch mechanism will move to the tripped position as cover is removed Released Producti...

Page 4: ...angereuse Danger de mort ou risque de blessures graves Hazardous Voltage Will cause death or serious injury Desenergice totalmente antes de instalar o darle servicio Reemplace todas las barreras y cubiertas antes de energizar el interruptor 4 5 I L No 810519A00 6 Prepare new handle for assembly If the handle shield is separate from the handle snap them together as shown below Apply appropriate rat...

Page 5: ... Test Operation Cycle device from OFF to ON to OFF to verify operation Call Technical Support if device does not operate correctly Turn OFF device Replace all covers and close the enclosure door before power supplying this device is turned on Cover Screws Cover Screws Cover Screws 2 6 32 X 1 1 4 Round Head Cover Screws 3 6 32 X 3 8 Pan Head 9 Move handle from TRIP to OFF position Tripped OFF O 3X ...