background image

Issued by
Siemens Switzerland Ltd
Smart Infrastructure
Global Headquarters
Theilerstrasse 1a
CH-6300 Zug
Tel. +41 58 724 2424
www.siemens.com/buildingtechnologies

© 2021 Copyright Siemens Switzerland Ltd

Data and design subject to change without notice.

Document ID

A6V10421792_----_g

A5Q00068583

Manual FC360

23

X26: Terminal of PC connection

1 : Ethernet, shielded patch cable, type CAT 5, CAT 5e,

CAT 6, CAT 6e or CAT 7, max. 100 m

24

en

Open a browser (e.g., Google Chrome or Firefox) and enter 'fc360.siemens.com'.
Configure by 'FC360 Panel Configurator' and test the system.
Change the default login password for security reason. See document A6V10450595 for more details.

de

Einen Browser öffnen (z. B. Google Chrome oder Firefox) und 'fc360.siemens.com' eingeben.
Mit 'FC360 Panel Configurator' konfigurieren und System testen.
Voreingestelltes Login-Passwort aus Sicherheitsgründen ändern. Mehr Infos siehe Dokument A6V10450595.

fr

Ouvrir un navigateur (p. ex. Google Chrome ou Firefox) et taper 'fc360.siemens.com'.
Configurer avec 'FC360 Panel Configurator' et tester le système.
Pour des raisons de sécurité, veuillez modifier votre mot de passe de connexion par défaut. Cf.

document A6V10450595 pour plus de détails.

es

Abra un navegador (p. ej., Google Chrome o Firefox) e introduzca 'fc360.siemens.com'.
Lleve a cabo la configuración por medio del 'FC360 Panel Configurador' y pruebe el sistema.
Cambie la contraseña de acceso predeterminada por razones de seguridad. Consulte el

document A6V10450595 para obtener más información.

it

Aprire un browser Internet (Ad es. Google Chrome o Firefox) e digitare l’indirizzo 'fc360.siemens.com'.
Configurare con il 'FC360 Panel Configurator' e testare il sistema.
Per motivi di sicurezza, modificare la password di accesso predefinita. Per maggiori dettagli vedere il

document A6V10450595.

A6V10421795

siemens.com

downloads.siemens.com

FC361-ZZ
FC361-ZA
FC362-ZZ
FC362-ZA

Summary of Contents for FC361-ZA

Page 1: ...el de Brandmeldezentrale fr Équipement de contrôle et signalisation es Unidad de control de detección de incendios it Centrale rivelazione incendio en Installation FC361 ZZ S54433 C112 A1 FC361 ZA S54433 C111 A1 FC362 ZZ S54433 C119 A1 FC362 ZA S54433 C120 A1 de Montage fr Montage es Montaje it Montaggio ...

Page 2: ...le FCA1209 Z1 1 Connection of sounder line 2 Aux power supply DC 24 V 0 2 A 3 Connection as Input 4 Connection as Unmonitored output 5 Connection as RT fire output 6 Connection as RT fault output 7 Connection as Fire control output 8 Connection of detector line s 9 en Switch on main supply AC 230 V de Netzspeisung AC 230 V einschalten fr Allumer l alimentation réseau AC 230 V es Conectar la fuente...

Page 3: ...ria BR Brazil CZ Czech Republic DE Germany GR Greece Login L1 Password 4 digits Select Language Bulgarian Croatian Czech Dutch Dutch Belgium English Main menu L3 1 System status 2 Operation 3 Event memory 5 Lamp test 6 Engineering 7 Logout Message Configure automatically Yes OK or No Cancel Engineering L3 1 Set date time 2 Edit name password 3 Detector line 4 Calibrate 4M card line 5 Alarm counter...

Page 4: ...wort aus Sicherheitsgründen ändern Mehr Infos siehe Dokument A6V10450595 fr Ouvrir un navigateur p ex Google Chrome ou Firefox et taper fc360 siemens com Configurer avec FC360 Panel Configurator et tester le système Pour des raisons de sécurité veuillez modifier votre mot de passe de connexion par défaut Cf document A6V10450595 pour plus de détails es Abra un navegador p ej Google Chrome o Firefox...