en
Installation and connection
8
Before Leaving
Check all connections for gas leaks with soap and
water. DO NOT use a naked flame for detecting leaks.
Ignite all burners both individually and concurrently to
ensure correct operation of gas valves, burners and
ignition. Turn gas taps to low flame position and
observe stability of the flame for each burner
individually and all together. Adhere the duplicate data
plate to an accessible location near the hotplate. When
satisfied with the hotplate, please instruct the user on
the correct method of operation. In case the appliance
fails to operate correctly after all checks have been
carried out, refer to the authorised service provider in
your area.
It should be expressly noted that we cannot accept any
liability for direct or indirect damage caused by wrong
connection, leakage or improper installation. When
being repaired, the appliance must always be
disconnected from the mains supply; if required, notify
our customer service.
Converting the cooktop from Nat. Gas to
Universal LPG
All work involved in installation, setting and adaptation
to a different gas type must be carried out by a licensed
gas fitter and must comply with current regulations and
the conditions laid down by the local gas company.
Before conversion the cooktop must be disconnected
from the electricity and gas valves must be turned to the
OFF position.
Important:
After finishing, stick the sticker, indicating
the new gas type, close to the specifications plate.
Replacing the injectors
Request change-over injectors from our customer
service deparment (refer injector chart below for sizes).
1.
Remove all pan supports, burner caps and
distributors.
2.
To replace the injectors, use the key that is available
from our technical service with code 340847 (for
double-flame burners 340808). See table. It is
important to make sure that the injector does not
become detached during removal or fastening. They
must be properly tightened to ensure that there are
no leaks.
With these burners, there is no need to adjust the
primary air.
3.
Fasten the distributors and burner caps to the
corresponding burners. In addition to this, put the
pan supports in place on the corresponding burners.
Natural Gas
Universal LPG
Hourly Gas
Consumption
(MJ)
Injector
mark
Hourly Gas
Consumption
(MJ)
Injector
mark
Economy
burner
4
88
3.5
50
Standard-
output
burner
6.85
116
6
66
High-output
burner
11
153
11
87
Wok burner
4 kW
15
181
13
98
Dual wok
burner
5 kW
19.5
190
16.5
96
77
45
Summary of Contents for EC6A5IB90A
Page 18: ......
Page 19: ......
Page 20: ...0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV 9001124166 9001124166 001214 ...