background image

Operating the appliance       

en

7

Connecting the remote control to the appliance

If the appliance cannot be operated with the remote 

control, e.g. after the battery has been changed, the 

connection between the remote control and the 

appliance must be re-established.

1.

Press and hold the 

@

 button.

2.

Attach the appliance to the mains voltage.

A long audible signal sounds. The remote control 

has been connected to the appliance.

Note: 

If no audible signal sounds within 30 seconds, 

repeat this procedure.

Extractor hood's control panel

Operating buttons

Setting the fan

Note: 

Always adjust the setting according to the current 

conditions. To eliminate strong cooking smells, select a 

high fan setting.

Switching on

1.

Press the 

@

 button.

The fan will start at fan setting 

ƒ

.

2.

Press the 

@

 or 

 A

 button to set a different fan setting.

Note: 

The appliance has three fan settings and an 

intensive setting. To set the lowest setting, 

press 

A

 once. If you press it more than once, the 

appliance will switch off again.

Switching off

Press and hold the 

A

 button until the appliance 

switches off.

or

 press the 

$

 button.

Intensive setting

You can use the intensive setting if there is a large 

build-up of odours and fumes/vapours.
Press and hold the 

@

 button until 

˜

 appears in the fan 

settings display .

Note: 

Intensive mode runs for four minutes. Once this 

time has elapsed, the appliance will switch back to fan 

setting 

ƒ

.

Intermittent mode

Intermittent mode automatically switches on the 

extractor hood for 10 minutes every hour. The function 

switches itself off again after 24 hours.
This function can be activated from the control panel or 

using the remote control.

Note: 

If intensive mode or the run-on function has been 

activated, the intermittent function will not be available.

Switching on intermittent mode from the control panel

1.

Press the 

$

 and 

@

 buttons at the same time until 

 

appears in the display.

2.

Press the 

@

 button. The following fan settings will 

appear in the display: 

ƒ

~

~

~

ƒ

, etc. 

3.

Press the 

$

 and 

@

 buttons at the same time to 

confirm the fan setting for intermittent mode.

Switching on intermittent mode using the remote 

control

1.

Press the 

H

 button. 

 will appear on the display.

2.

Press the 

@

 button. The following fan settings will 

appear on the display: 

ƒ

~

~

~

ƒ

, etc.

3.

Press the 

H

 button to confirm the fan setting for 

intermittent mode

Note: 

Pressing any of the buttons (except the button for 

the light) will deactivate intermittent mode.

Run-on function

The run-on function allows the extractor hood to 

continue running for a few minutes after it has been 

switched off. This eliminates any remaining cooking 

smells. The extractor hood will then switch itself off 

automatically.

Switching on

Note: 

If intensive mode has been activated, the run-on 

function will not be available.

Press the 

*

 button on the control panel or the 

y

 

button on the remote control.
The fan will run for 10 minutes at setting 

 and a dot 

will flash on the display during this time. Then the fan 

will switch itself off automatically.

(

Fan settings display 

0

Operating buttons

Explanation

=

Light on/off/dimming

$

Switches the extractor hood on and off

A

Decrease fan setting

@

Increase fan setting

*

Fan run-on

Summary of Contents for DID09T951

Page 1: ... en Instruction manual Extractor hood DID09T951 DID09T951B ...

Page 2: ......

Page 3: ...ler is responsible for ensuring that the appliance works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended ...

Page 4: ...arning Risk of fire Grease deposits in the grease filter may catch fire Clean the grease filter at least every 2 months Never operate the appliance without the grease filter Risk of fire Grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a heat producing appliance for solid fuel e g wood or coal un...

Page 5: ...faces in the direction of the grain only Do not use any stainless steel cleaners for operator controls Surface damage due to strong or abrasive cleaning agents Never use strong and abrasive cleaning agents Risk of damage from returning condensate Install the exhaust duct in such a way that it falls away from the appliance slightly 1 slope 7Environmental protection Environmentalprotection Your new ...

Page 6: ... confirm that a button has been pressed Note Switch on the extractor hood when you start cooking and switch it off again several minutes after you have finished cooking This is the most effective way of removing the kitchen fumes Controls Use the remote control to set and adjust the various different functions of your appliance Note The remote control requires 23AE 12 V batteries For information o...

Page 7: ...for 10 minutes every hour The function switches itself off again after 24 hours This function can be activated from the control panel or using the remote control Note If intensive mode or the run on function has been activated the intermittent function will not be available Switching on intermittent mode from the control panel 1 Press the and buttons at the same time until appears in the display 2...

Page 8: ...ppliance to cool down before cleaning Warning Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Warning Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Warning Risk of inj...

Page 9: ...o not clean heavily soiled metal mesh grease filters together with utensils Place the metal mesh grease filters loosely in the dishwasher The metal mesh grease filters must not be wedged in Removing metal grease filter 1 Open the filter cover by pulling it downwards Notes The filter cover is heavy Hold the filter cover with both hands Open the filter cover slowly and carefully 2 Press the lock on ...

Page 10: ...visit by an after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried out by trained service technici...

Page 11: ...Accessories for air recirculation mode en 11 _Accessories for air recirculation mode Accessoriesforairrecirculationmode not supplied DSZ5300 DSZ5201 ...

Page 12: ...3PCFSU PTDI BVTHFSÉUF NC XXX CPTDI IPNF DPN BSM 8FSZ 4USB F ßODIFO 3 9001289769 9001289769 970221 ...

Reviews: