9
GB
■
If warm water is not required for an extended period, set
the tank to frost protection mode with button 6
Only red LED 9 lights up.
■
The tank must be drained fully by our customer service
department or an authorised specialist in order to avoid
frost damage, if the appliance is disconnected from the
electrical supply.
■
The device should be disconnected from the mains supply
when working on the water supply.
Error signals
■
LEDs 9 and 2 flash
Overheating protection has been activated.
Call customer service.
■
LEDs 9 and 3 flash
The anode is spent and must be replaced.
Customer service must be contacted as otherwise
corrosion prevention is no longer guaranteed.
The device can continue to be used for a very short time
with the “heat once” function.
■
LEDs 9 and 4 flash
The temperature sensor is defective.
Call customer service.
Cleaning
■
Clean externally with a mild cleaning agent. Do not use
aggressive or abrasive detergents!
Maintenance/Customer Service
■
Repairs and other maintenance work may only be
carried out by one of our authorized customer service
representatives in order to avoid potential sources of
danger.
■
When you contact customer service, please quote the E
and FD numbers on your appliance (Fig. A).
■
The first inspection must be carried out no later than 2
years subsequent to initial startup of the appliance. This
involves inspection of the protection anode which may
need to be replaced, and the appliance may need to be
cleaned and descaled. The customer service will suggest
the next inspection date for a service.
■
The power supply and the water supply must be shut off
before all work on the appliance.
T e c h n i c a l d a t a
Rated capacity
[l]
30
50
80
100
Rated voltage
[V]
220–240 (~ 50 Hz)
Rated output DGxxx31E
Rated output DGxxx31R
Rated output DGxxx31P
[W]
1500
2000
2000
Rated current DGxxx31E
Rated current DGxxx31R
Rated current DGxxx31P
[A]
6.5
8.7
8.7
Fuse protection
[A]
10
Protection type/class
IP24D
Rated over-pressure DGxxx31E
Rated over-pressure DGxxx31R
Rated over-pressure DGxxx31P
[Mpa]
0.9
0.9
0.6
Cold and warm water connection
G 1/2"
Corrosion prevention
Magnesium protection anode
Warm water temperature range
[°C]
approx. 35-75
Frost protection
[°C]
approx. 10
Insulation thickness
[mm]
45
40
Stand-by power consumption at
65 °C
[kWh/d]
0.55
0.7
0.9
1.1
Mixed water quantities at 40 °C
(15 °C/65 °C)
[l]
54
90
144
180
Heating time (inlet 12 °C -> 60 °C)
DGxxx31E
DGxxx31R/DGxxx31P
[min]
68
51
114
85
182
137
228
171
Weight [filled]
[kg]
49
70
107
131
Dimensions (H x W x D)
[cm]
55 x 42 x 40
62 x 46 x 44
89 x 46 x 44
107 x 46 x 44
Summary of Contents for DG10031E
Page 30: ...30 ...
Page 31: ...31 ...
Page 34: ...A Siemens Elektrogeräte GmbH E Nr FD ...
Page 36: ...C 6 Zulauf Auslauf 5 4 3 2 1 7 8 6 Zulauf Auslauf 5 4 3 2 1 7 8 E 1 9 6 2 5 4 8 7 3 D ...