The BCS is designed primarily as a hand-held operator terminal. As an alternative, a
bracket is available, which can be screwed onto any surface. The service terminal can
be clipped onto this bracket when not in use. The BCS may, however, also be mounted
in a control panel front, if required. The service cable, which incorporates the LON bus
and power supply, can be plugged into the service socket of a controller.

–  Case for protection of service terminal (e.g. in tool boxes) and User Manual, R23
–  Service cable, 3 m long
–  Wall bracket. See Manual R21 section 04.20 for detailed installation instructions.

Overview

Overview

Device list

Overview

Device 1 (RC.., BCE, BCS, 

APED30)

60269EN

Device n

BCS settings

Operating level

Subnet selection

Comms. protocol

Data representation

Language information

Definition devices 

Device registration 

Remove device

Alarms / Network time 

Last 32 alarms 

Set bus time / date 

Overview
(e.g. RCK-WU)
Important datapoints
Week program
Date program
Proportional seq. Y1
Proportional seq. Y3
Proportional seq. Y5
Value of cascade
Setpoint reset
Regulation sensor X1
Shift sensor X2
Setpoint External
Output Heating Y1
Output Cooling Y3
Output heat Y5
Output Digital Y2
Alarm
Output Clock
Frost sensor X4
Output Frost
Control relay Step 1
Control relay Step 2
Structure data
Alarm summaries
Device data

Internal setting

Overview

Overview

Overview

Check network

Operating level 1

Operating level 2

Operating level 3

2)

3)

2)

2)

2)

2)

3)

3)

3)

2)

2)

2)

2)

2)

2)

2)

2)

2)

2)

2)

2)

3)

3)

3)

3)

3)

3)

3)

3)

3)

3)

3)

3)

3)

Display

The display window accommodates 10 lines of
26 characters each. The first two lines display the
controller and the menu option. The remaining
eight lines are used to display the data
associated with the selected menu.

Fields and symbols

5051 1

d e f

c

a

g

g

b

b

Field

Symbol

Description

a

Path (two lines)

b

Data field (eight lines)

a / b

Forced value
Alarm
Unstructured controller
Undefined device
Battery discharged

c

More data to the left

d

More data to the right

e

BCS busy

Activity on bus

Bus error

f

Alarm received

g

Position indicators, more data in direction of arrow

Mounting

Accessories

Operating notes

Menu tree

Display and indication

Summary of Contents for DESIGIO 30

Page 1: ...tion keys Selected points are displayed in inverse video and adjustable values can be modified with the and keys Modified values are accepted with enter and functions are terminated with the esc key 50169A esc 1 2 3 4 Key 1 Display 2 Info key 3 Edit keys 4 Navigation keys Operating level 1 level on start up For access to all the controller values needed for normal operation plant status all inputs...

Page 2: ...eek program Date program Proportional seq Y1 Proportional seq Y3 Proportional seq Y5 Value of cascade Setpoint reset Regulation sensor X1 Shift sensor X2 Setpoint External Output Heating Y1 Output Cooling Y3 Output heat Y5 Output Digital Y2 Alarm Output Clock Frost sensor X4 Output Frost Control relay Step 1 Control relay Step 2 Structure data Alarm summaries Device data Internal setting Overview ...

Page 3: ...e bus and for password entry 50505Aen X1 21 0 C X2 14 0 C X3 23 0 C X4 10 0 C Y1 5 3V Y3 0 0V FRIND On Y2 0 0V Ventilation East Important datapoints YD1 On YD2 Off CLCK Auto I W 20 0 C MODE Auto XB 5 0 C XON 5 0 C FCOF 1 0K Modifying a value Use the navigation keys to select the value If modi fiable the value will be displayed in inverse video Prepare to modify value by pressing The value will fla...

Page 4: ... comms and power LON with BACnet protocol Connection 2 wire comms only without AC 24 V Max cable length 1100 m unscreened Bus termination On rear set by switch Weight excluding packaging 0 38 kg Dimensions W x H x D 110 x 210 x 45 mm Cleaning Use a damp cloth only Use soap or solvent only Do not allow moisture to enter the housing Conditions of use For indoor use Temperature range Operation 5 45 C...

Reviews: