6
ATEX version gearboxes
The difference between the temperature of the housing and the ambient
temperature of max. +40° C must not exceed 70 K.
Using a suitable temperature sensor, measure the temperature at the lowest point
of the housing (oil sump) or at the mounting surface in the case of output units. We
recommend that you monitor the gearbox temperature indirectly by monitoring the
motor current.
Changes are an indication of possible incipient damage.
CAUTION
Malfunctions can cause injuries or gearbox damage
In the event of changes during operation, the drive unit must be switched off immediately.
Determine the cause of the fault using the fault table (Page 61). Remedy faults or have
faults remedied.
Check the gearbox during operation for:
●
Excessive operating temperature
●
Changes in gear noise
●
Possible oil leakage at the housing and shaft seals