User Manual for AyAlarm
AyTerminal
V2.1
AyAlarm application
Temperature
Current: +24 °C
>
+35
°C
Temperatur
curr.:+24°C
>
+35
°C
Figure 5-47 Temperature adjustment screen
The first threshold value of the sensor is the default value (the default value can not be modified
using the AyApplication).
To increase/ decrease the threshold value use the up/ down buttons.
To leave this screen and to save the value press the Enter button (OK button). In this moment the
entered value will be saved and previous screen is shown.
To leave this screen and returning to previous screen without changing the threshold press the
Cancel button.
No validations are made when leaving this screen.
If any problem occurred while saving the threshold a message box containing a proper message is
displayed. The message text is: “The value could not be saved. Please try again”. The message
box with the defined message is shown for 4 seconds. Otherwise previous screen without
notification is shown.
5.4.4.6Activation delay
Between the moment of activating the mode and activating the sensor there can be a delay. This
delay is called Activation delay; it is configurable. The set time is applied to all sensors used and
activated for the selected mode. This option is useful when some time is needed to place the
AyTerminal in the desired place (e.g. baggage) after activating a mode.
The activation delay is set in seconds, up to 255 seconds.
00:01:00
Activation delay
OK
01:00:00
Activation d
OK
Figure 5-48 Set activation delay screen
Enter a new Activation delay value. To leave this screen and set the value first select OK and after
that press the enter button. In this moment the entered number is validated and if greater than
255s then the device will play a negative acknowledge tone and for 4 seconds will display a
message box with a defined text (“Activation delay can’t be more than 255s”). After that the
previous menu is displayed. Otherwise it will play a positive acknowledge tone and will return to
previous screen.
5.4.5
Duration
Using this menu item it is possible to define the time for that the mode is set into the alarm state if
an alarm is triggered. Also the same time is used to set the time for that the Siren is activated.
Minimum value for duration is 15s and maximum is 30 minutes. If duration is set to 0 (special
case), the state alarm is left only on deactivation code (“forever alarm”).
5.4.6
Overview
Purpose is to overview the mode settings in a message box with all set values (see Figure 5-49).