ConfigurationsChange settings
4
24 | 40
A6V11160936_en--_c
Step
Description
Picture
Page 10
Page 11
Page 12
Page 1: ...QSA2700D QSA2700 AQS2700 Fine dust room sensor Basic Documentation A6V11160936_en _c Smart Infrastructure 2019 04 10 ...
Page 2: ...2700 18 4 4 1 On event addressing ClimatixTM controllers configuration 18 4 4 2 Reset Modbus parameter 19 4 5 LED colors and patterns QSA2700 19 4 6 Initial setup QSA2700D 19 4 7 Change settings 21 4 7 1 Change language QSA2700D 21 4 7 2 Change Air Quality Index class QSA2700D 22 4 7 3 Change display format QSA2700D 23 4 7 4 Change theme QSA2700D 25 4 8 Analog output range selection QSA2700D 25 4 ...
Page 3: ...40 6 Maintenance 33 6 1 Replacing AQS2700 33 6 2 Proximity sensor QSA2700D 34 6 3 Troubleshooting 35 6 4 Disposal 35 7 Air Quality Index classes 36 8 Standard compliance 37 9 Appendices 38 9 1 Cyber security disclaimer 38 ...
Page 4: ......
Page 5: ...expressed permission of Siemens Switzerland Ltd These documents were prepared with great care The content of all documents is checked at regular intervals All necessary corrections are included in subsequent versions Documents are automatically amended as a consequence of modifications and corrections to the products described Please make sure that you are aware of the latest document revision dat...
Page 6: ...s the products equipment applications tools and so on carefully and in full Before you get started make sure you have an internet connection a valid Email address and a smartphone in hand Additional information on products and applications is available From your Siemens branch office www siemens com sbt or at your system suppliers From the support team at headquarters fieldsupport zug ch sbt sieme...
Page 7: ...M2 5 values Air Quality Index and service AQS2700 S55720 S459 Sensor module for replacement 2 2 Contents of QSA2700D and QSA2700 Items Quantity Fine dust sensor 1 Plastic mounting plate 1 Screws 2 pcs Mounting instructions 1 2 3 Features The fine dust room sensor is designed to measure and transmit indoor concentrations of PM2 5 and PM10 0 10 V and Modbus output Configurable Modbus parameters Quic...
Page 8: ...or wiring top for surface mounting 2 QSA2700 only LED 3 QSA2700D only LCD display 4 power supply for display only 5 QSA2700D only Proximity sensor 6 Push button 7 Hole for wiring bottom for surface mounting 8 Hole for attaching the mounting plate to the housing 9 Air outlet 10 Air inlet ...
Page 9: ..._c 9 40 2 5 Normal display overview of QSA2700D 1 PM2 5 value in μg m3 2 The current Air Quality Index category 3 PM2 5 trend in rolling 24 hours 4 Particle numbers PM2 5 in μg m3 PM2 5 PM10 in μg m3 PM2 5 PM10 in μg m3 24 hours trend PM2 5 PM10 in μg m3 and particles m3 ...
Page 10: ...ensor readings Make sure ambient conditions are within 0 50 C and 5 95 r h no condensation Do not mount device in places full of oil smog e g in a kitchen Peel off the protective film on air inlet and air outlet before using The air inlet and outlet must be free of any blockage particularly the floc type of dirt NOTICE High concentrations of cigarette oil smog in for example smoking rooms may affe...
Page 11: ...to 1 5 mm2 Analog output 0 4 to 1 5 mm2 Modbus output Twisted pair 0 4 to 1 5 mm2 Length 600m 3 2 Wiring G G0 Operating voltage AC 24 V SELV DC 13 5 35 V U1 Signal output DC 0 10 V for PM2 5 with selected range in μg m3 U2 Signal output DC 0 10 V for PM10 with selected range in μg m3 Gu Signal ground for U1 U2 Ref Modbus signal Mounting dimensions Mounting tools Wire specification ...
Page 12: ...ate the housing from the mounting plate using a screw driver 2 Screw and fix the mounting plate on a conduit box Conduit box mounting or on a wall Dry wall mounting if there is a mounting hole and the wires are concealed in the hole Surface mounting if there is no mounting hole ...
Page 13: ...n _c 13 40 3 Connect and screw wires correctly to the terminal For surface mounting you must break out the wiring hole at the top or bottom first 4 Attach the housing to the mounting plate at the top and then snap on the housing at the bottom ...
Page 14: ...3 1 8 N 2 0 Basic Parity Even Odd No Even Stop bits 1 2 1 Connection 32pcs line Data 8 bits 0 255 Identity Slave Cable length 600m 4 2 Modbus registers Software version 1 2 12 The following Modbus registers are used in software version 1 2 12 and previous Holding Register 16 bit No Name Description Default R W 257 PM2 5 value Range 0 500 R 258 PM10 value Range 0 500 R 260 Sensor working status 0 N...
Page 15: ...n is 1 byte minor version is 1 byte and build version is 2 bytes such as 2 01 33 0x02010021 4 3 Modbus registers Software version 1 3 13 The following Modbus registers are used in software version 1 3 13 and later Holding Register 16 bit No Name Description Default R W 9 PM2 5 value Range 0 500 R 10 PM2 5 reliablility 0 No error 1 Bad reliability or not available R 11 PM10 value Range 0 500 R 12 P...
Page 16: ...3 0 R W 217 Temperature value via bus 40 120 Resolution increment is 1 R W 218 Relative humidity value via bus 0 100 Resolution increment is 1 R W 219 Data receiving interval via bus in min for temperature relative humidity 1 60 min 20 R W 221 Enable temperature and relative humidity display via bus 0 disable default 1 enable 0 R W 1286 Software version Major and minor version R 1287 Software vers...
Page 17: ...alue PM2 5 PM10 in μg m3 is selected as display format Register values are transmitted from the master In the case of a multiple writing command from the master with invalid values the sensor rejects the command with an error notice The register values remain unchanged Bus configuration command 768 is for on event addressing only Software version format major version is 1 byte minor version is 1 b...
Page 18: ... Communication is established automatically when Baud rate is 19200 default Format is 1 8 E 1 default Address is 246 Then Master writes the Modbus parameters Master writes 1 into register 4x0768 Bus configuration command to activate the change After a successful pairing the LED flashes green for 60 s then turns to permanent green Otherwise the LED turns back to its original state LED flashes yello...
Page 19: ...esetting if releasing the button Release after 13 s resetting is cancelled Remark 1 Only Modbus address baud rate and transmission format are reset to factory default 4 5 LED colors and patterns QSA2700 Color Pattern Description Green Permanently on Working properly Modbus configured Yellow Permanently on Working properly Modbus with factory settings Red Permanently on Error 1 replace sensor modul...
Page 20: ... page 2 Then in page 2 1 Short press to select among the different classes 2 Long press 2 s to save the selection and then enter next page page 3 Tip refer to Air Quality Index classes 36 for more info about AQI Page 2 3 From page 2 long press 2 s to enter page 3 Initial setup is completed Page 3 4 From page 3 short press to enter page 4 Then in page 4 scan the QR code for the link to download the...
Page 21: ...eps short press means short press the push button long press 2 s means long press the push button 2 10 s 4 7 1 Change language QSA2700D Step Description Picture 1 From page 4 short press to enter page 5 Then in page 5 Short press to enter next page page 6 Long press 2 s to enter page 5 1 Page 5 2 In page 5 1 1 Short press to select a language 2 Long press 2 s to save the selection and back to page...
Page 22: ...A2700D Step Description Picture 1 From page 5 short press to enter page 6 Then in page 6 Short press to enter next page page 7 Long press 2 s to enter page 6 1 Page 6 2 In page 6 1 1 Short press to select an Air Quality Index class 2 Long press 2 s to save the selection and back to page 6 Page 6 1 ...
Page 23: ...elect a display value format 2 Long press 2 s to save the selection and back to page 7 Page 7 1 3 From page 7 short press to enter page 8 Then from page 8 short press to enter page 3 if selected display value is PM2 5 μg m3 page 9 if selected display value is PM2 5 PM10 μg m3 If humidity and temperature value display is enabled enter page 10 page 11 if selected display value is Value μg m3 24hrs t...
Page 24: ...Configurations Change settings 4 24 40 A6V11160936_en _c Step Description Picture Page 10 Page 11 Page 12 ...
Page 25: ...Short press to enter next page selected normal display e g page 3 Long press 2 s to enter page 8 1 Page 8 2 In page 8 1 1 Short press to select a theme color 2 Long press 2 s to save the selection and back to page 8 Page 8 1 4 8 Analog output range selection QSA2700D In the following steps short press means short press the push button long press 2 s means long press the push button 2 10 s ...
Page 26: ... press to enter next page page 3 Long press 2 s to enter page 14 1 Page 14 4 In page 14 1 1 Short press to select a range 2 Long press 2 s to save the selection and back to page 14 Page 14 1 4 9 Modbus configuration QSA2700D Press the push button to automatically reset and configured via ClimatixTM controllers with pre programmed plug play configuration or manually configure via controller In the ...
Page 27: ...ngs local manual configuration 2 Configure via Climatix plug play with Climatix 3 Reset Modbus settings reset to factory default 4 Back go back to page 13 Page 15 3 1 When Modify Modbus settings is selected long press 2 s to activate the function For detailed operation refer to Modify Modbus settings QSA2700D 28 Page 15 3 2 When Configure via Climatix is selected long press 5 10 s to activate the ...
Page 28: ...activate the function Page 15 2 4 9 1 Modify Modbus settings QSA2700D Step Description Picture 1 From page 15 long press 2 s to enter page 16 Page 15 2 In page 16 Short press to enter next page page 17 Long press 2 s to enter page 16 1 Page 16 3 In page 16 1 1 Short press to select baudrate 2 Long press 2 s to save the selection and back to page 16 Page 16 1 ...
Page 29: ...17 Short press to enter next page page 18 Long press 2 s to enter page 17 1 Page 17 5 In page 17 1 1 Short press to select transmission format 2 Long press 2 s to save the selection and back to page 17 Page 17 1 6 From page 17 short press to enter page 18 Then in page 18 Short press to enter next page page 18 2 Long press 2 s to enter page 18 1 Page 18 ...
Page 30: ... press to enter page 18 2 Then in page 18 2 Short press to enter next page page 18 3 Long press 2 s to modify the values for second digitals same as step 6 1 Page 18 2 6 3 From page 18 2 short press to enter page 18 3 Then in page 18 3 Short press to enter next page page 13 Long press 2 s to modify the values for third digitals same as step 6 1 Page 18 3 7 The valid address range for Modbus addres...
Page 31: ...ding to selected measuring range 5 3 Functional data for PM10 Measuring range selectable 0 500 μg m3 0 300 μg m3 0 100 μg m3 0 50 μg m3 Unit to unit variability Analog output signal terminal U2 Max of 15 μg m3 and 15 of reading 25 C and 50 r h DC 0 10 V linear corresponding to selected measuring range 5 4 Connections Interface Micro USB Power connection for display only Wiring connections Screw te...
Page 32: ...61 000 6 3 EU conformity declaration A6V11277342 The document can be downloaded at http siemens com bt download 5 9 General data Color White Weight 140 g 5 10 Display QSA2700D Screen Color no touch Working status Only active when people in front within 1 m 10 screen turns off after a few minutes if no presence is detected Resolution 1 μg m3 increments Display Display PM2 5 value if value 500 μg m3...
Page 33: ...but is indicated via LED or LCD Refer to Troubleshooting 35 for the indication Sensor module accuracy is influenced by ambient environment We recommend to replacing the module every 1 to 3 years depending on the local environment In environments with continuously high PM2 5 concentrations i e greater than 300 μg m3 e g a smoking room replace the module more often To replace the sensor module l Det...
Page 34: ...uilt in proximity sensor and enters into energy efficient mode if no obstacle is detected in front of the sensor approximately 1 m over the past few minutes In energy efficient mode the screen is off and the sensor is working and transmitting the signals at regular intervals Otherwise the screen is activated and the sensor is in continuous working mode Keep the proximity sensor area clean as dirt ...
Page 35: ...ut change QSA2700 Red permanently on Error 1 replace sensor module Present 0 V 2 s and 10 V 2 s one by one in turn Value of register 209 changes from 0 to 1 QSA2700 Red flashing 0 5 s on 0 5 s off Error 2 communication error Present 0 V 5 s and 10 V 2 s one by one in turn Value of register 209 changes from 0 to 2 QSA2700 Red yellow flashing 0 5 s red 0 5 s yellow Warning of possible inaccurate mea...
Page 36: ...e for example AQI 1 50 Good represents a different range of values of PM2 5 in the U S 1 12 μg m3 and China 1 35 μg m3 These different conversions of PM2 5 to AQI country by country are reflected by different AQI classes The sensor QSA2700D for PM2 5 recognizes three different classes that can be selected during product commissioning Class I U S Class II China Class III India For European countrie...
Page 37: ...Standard compliance 8 A6V11160936_en _c 37 40 8 Standard compliance 1 The product complies with CE standard EN 61000 6 2 EN 61000 6 3 EN 60730 1 2 The product complies with the RoHS and RoHS CN standard ...
Page 38: ...an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures e g firewalls and or network segmentation are in place Additionally Siemens guidance on appropriate security measures should be taken into account For additional information please contact your Siemens sales representative or visit https www siemens com global en ho...
Page 39: ...Appendices Cyber security disclaimer 9 A6V11160936_en _c 39 40 ...
Page 40: ...t Infrastructure Global Headquarters Theilerstrasse 1a CH 6300 Zug 41 58 724 2424 www siemens com buildingtechnologies Siemens Switzerland Ltd 2017 Technical specifications and availability subject to change without notice A6V11160936_en _c ...