background image

Siemens Industry, Inc.
Building Technologies  Division

P/N 315-050263-3

3

The following table contains a description of controls accessible through the front
bezel of the ALCC:

E

M

A

N

E

P

Y

T

N

O

I

T

P

I

R

C

S

E

D

N

I

A

G

1

L

E

N

N

A

H

C

T

N

E

M

T

S

U

J

D

A

r

e

t

e

m

o

i

t

n

e

t

o

P

y

r

a

m

i

r

p

C

C

L

A

e

h

t

f

o

t

u

p

t

u

o

e

h

t

s

t

s

u

j

d

A

.

u

B

d

6

+

d

n

a

u

B

d

6

-

n

e

e

w

t

e

b

l

e

n

n

a

h

c

N

I

A

G

2

L

E

N

N

A

H

C

T

N

E

M

T

S

U

J

D

A

r

e

t

e

m

o

i

t

n

e

t

o

P

y

r

a

d

n

o

c

e

s

C

C

L

A

e

h

t

f

o

t

u

p

t

u

o

e

h

t

s

t

s

u

j

d

A

.

u

B

d

6

+

d

n

a

u

B

d

6

-

n

e

e

w

t

e

b

l

e

n

n

a

h

c

1

L

E

N

N

A

H

C

T

S

E

T

T

L

U

A

F

h

c

t

i

w

S

y

r

a

t

n

e

m

o

M

.

t

s

e

t

t

l

u

a

f

l

e

n

n

a

h

c

y

r

a

m

i

r

p

C

C

L

A

.

y

l

n

o

e

s

u

y

r

o

t

c

a

F

2

L

E

N

N

A

H

C

T

S

E

T

T

L

U

A

F

h

c

t

i

w

S

y

r

a

t

n

e

m

o

M

.

t

s

e

t

t

l

u

a

f

l

e

n

n

a

h

c

y

r

a

d

n

o

c

e

s

C

C

L

A

.

y

l

n

o

e

s

u

y

r

o

t

c

a

F

Figure 2

Installing The ALCC

WIRING

Remove all system power before installation, first battery then AC. (To power up,

connect the AC first, then the battery.)

All field wiring of the ALCC is connected to the CC-2/CC-5 terminal blocks located
above and below the card cage slot, in which it is installed.

To connect external wiring:

1.

Loosen the screw of the terminal by turning it counterclockwise.

2. Insert the wire into the side of the terminal block.
3. Tighten the screw of the terminal block by turning it clockwise.

For all versions of Zeus earlier than 7.0, the ALCC is not

an option under CC-5 or CC-2. As a result, such proper-

ties as card cage slot availability and battery / power

supply current draw must be accounted for manually

in those Zeus versions prior to 7.0.
It is recommended to install the ALCC in a slot adjacent

to the AIC.

INSTALLATION

The ALCC plugs perpendicularly into a CC-2 or CC-5 slot via two 96-pin DIN connec-
tors and can occupy any slot in the card cage.

Slide the ALCC card into the card guides front bezel up, until the card edge connec-
tors contact the motherboard receptacles. The LEDs, test buttons, adjustment
potentiometers, and the legend should be visible and accessible.

Verify that the card edge connectors align properly with
the motherboard receptacles. There is only one correct
way to plug in the card.  If it does not align, DO NOT
FORCE the card.

Place thumbs on the front panel adjacent to the captive
screws and gently apply even pressure on the card
until the connectors plug firmly into the motherboard
receptacles.  Secure the ALCC to the card cage with
captive screws.

Power up the system and verify that the ALCC power
LED turns ON.

Summary of Contents for ALCC

Page 1: ... located in the primary and secondary paging stations into a form that is compatible with AICs located in the remote stations The ALCC is transparent to the host system As such it supports all styles of wiring supported by ZAC 40 XLS Desigo Fire Safety Modular Cerberus PRO Modular as well as ZAC 30 MXL amplifiers It provides supervision by constantly monitoring its two audio channels reporting fau...

Page 2: ... Safety Modular Cerberus PRO Modular system The ALCC contains no digital circuitry and integrates seamlessly into the existing XLS Desigo Fire Safety Modular Cerberus PRO Modular framework as it is com pletely transparent to the overlying system structure Refer to the ALCC Usage Restrictions on page 8 Controls and Indicators The following table contains a description of LED indicators visible thro...

Page 3: ...stalled To connect external wiring 1 Loosen the screw of the terminal by turning it counterclockwise 2 Insert the wire into the side of the terminal block 3 Tighten the screw of the terminal block by turning it clockwise For all versions of Zeus earlier than 7 0 the ALCC is not an option under CC 5 or CC 2 As a result such proper ties as card cage slot availability and battery power supply current...

Page 4: ... or ZAM 180 LED switch LED VSM 1 LED switch LED ACM 1 not required for global paging from an MXLV head end XNET ZAC 40 DAC NET NIC C SCM 8 ALCC LVM ALCC NIC C DAC NET AIC AUDIO AUDIO PRESENT AIC CONTACT XLSV Desigo Fire Safety Modular Cerberus PRO Modular MXLV XLSVR Desigo Fire Safety Modular Cerberus PRO Modular NIC C ZAC 40 or ZAM 180 LED switch LED LVM MMM 1 NIM 1W NIC C DAC NET HNET HNET LED L...

Page 5: ...igo Fire Safety Modular Cerberus PRO Modular PRIMARY AUDIO RISER 1 ZAC 40 ZAC 40 ZAC 40 ZAC 40 PRIMARY AUDIO RISER 2 SECONDARY AUDIO RISER 1 SECONDARY AUDIO RISER 2 ALCC ALCC AIC SECONDARY RISER AUDIO SECONDARY PRESENT CONTACT PRIMARY RISER AUDIO PRIMARY PRESENT CONTACT REMOTE PAGING STATION XLSV Desigo Fire Safety Modular Cerberus PRO Modular XLSV Desigo Fire Safety Modular Cerberus PRO Modular F...

Page 6: ... capacitance is 0 33 μF Line to Line 0 66 μF Line to Ground max for each audio riser 6 Parallel wiring T tapping is not allowed 7 All ALCC audio riser wiring is rated power limited and should be wired in accordance with applicable codes 8 The ALCC supports both Class A and Class B audio riser wiring Refer to Figure 6 for details Figure 5 outlines the input and output connections of the ALCC and th...

Page 7: ...50263 3 7 Figure 6 ALCC Class A and Class B Wiring Diagram GLOBAL PAGING STATION CLASS A EOLR 68k OHMS ZAC 40 XLS Desigo Fire Safety Modular Cerberus PRO Modular or ZAC 30 MXL CLASS B EOLR 68k OHMS CLASS A ONLY AUDIO RISER CLASS A and CLASS B LAST ALCC FIRST ALCC ...

Page 8: ...is limited at 160W For ULC approved product the following usage restrictions apply a The maximum power of the ZAM 180 amplifier using the ZAC 40 XLS Desigo Fire Safety Modular Cerberus PRO Modular as the ALCC paging source is limited at 165W b The ZAC 30 MXL is not allowed as the ALCC paging source Document ID A6V10248630 Cyber security disclaimer Siemens products and solutions provide security fu...