background image

Summary of Contents for AFI5100

Page 1: ...SiPass integrated AFI5100 Installation manual Fire Safety Security Products Siemens Building Technologies ...

Page 2: ...ne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder außerhalb des Zweckes verwenden zu dem es ihm übergeben worden ist We reserve all rights in this document and in the subject thereof By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part nor to make t...

Page 3: ...s 5 1 3 Prerequisites 5 1 4 Expected Installation Time 6 1 5 Mounting Instructions 6 1 6 Wiring 6 1 7 Links and Jumpers 9 1 8 LEDs 10 1 9 Recommended Cable Specifications 11 1 10 Programming and Firmware Download 11 3 Siemens Building Technologies Fire Safety Security Products 02 2005 ...

Page 4: ...4 Siemens Building Technologies Fire Security Products 02 2005 ...

Page 5: ...atus of all input devices connected for example Passive Infrared Detectors PIRs Any changes in state are instantly communicated to the ACC and then on to the Host system if necessary 1 2 Product Numbers 6FL7820 8CB10 AFI5100 Input Point Module and base plate 1 3 Prerequisites Input Devices to be connected to the IPM Cabling RS 485 Required Tools Materials Medium duty drill and associated drill bit...

Page 6: ... its operation 9 This step may require installation and programming of the access control host software and download of the firmware instruction set Alternatively the firmware and configuration may be carried out using the FLN Field Service Tool 1 6 Wiring It is recommended that you wear a grounding strap while carrying out this proce dure 1 Connect all input devices to the INPUT ports Listed end ...

Page 7: ... ACTIVITY TX COMMS LK14 LK13 LK12 LK11 LK1 Nc C No LK 9 LK3 RX COMMS INPUT 1 IN IN IN IN INPUT 5 INPUT2 IN IN IN IN INPUT 6 INPUT 3 IN IN IN IN INPUT 7 INPUT 4 IN IN IN IN INPUT 8 INPUT 9 IN IN IN IN INPUT 13 INPUT 10 IN IN IN IN INPUT 14 INPUT 11 IN IN IN IN INPUT 15 INPUT 12 IN IN IN IN INPUT 16 INPUT 17 IN IN IN IN INPUT 21 INPUT 18 IN IN IN IN INPUT 22 INPUT 19 IN IN IN IN INPUT 23 INPUT 20 IN...

Page 8: ...T21 INPUT22 INPUT23 INPUT24 INPUT9 INPUT10 INPUT11 INPUT12 INPUT13 INPUT14 INPUT15 INPUT16 INPUT25 INPUT26 INPUT27 INPUT28 INPUT29 INPUT30 INPUT31 INPUT32 FOR IN IN IN FOR NORMAL LK5 LK7 LK8 FOR EN FOR DIS LK 10 S N LK2 LK4LK6 FOR ENABLE FOR OUTPUT1 OUTPUT2 OUTPUT3 OUTPUT4 DC OUT 2 DC OUT 1 9 4 5 6 7 8 1 2 3 The following table provides a brief description of each port Port Name Brief Description ...

Page 9: ...de LK7 If the jumper on Link 7 is taken off it is set to Partial Reset mode LK8 This is a General Purpose links that has been included for further enhancement of the system LK9 Memory Clear and Reset Setting LK9 and turning the power off and on will reset the IPM A full or partial reset can be achieved by setting LK7 on or off If LK7 is set the IPM will fully reset and any firmware loaded into the...

Page 10: ... COMMS The Transmission COMMS LED flashes when the IPM is sending data to the ACC to which it has been connected via an FLN Rx COMMS The Transmission COMMS LED flashes when the IPM is receiving data from the ACC to which it has been connected via an FLN Inputs The tricolor Input Port LEDs indicate the current status of the input port See the table below for an explanation of the colors Outputs Eac...

Page 11: ...foil Polyester tape no braid PVC RS422 8 4 24 7 x 32 Tinned Copper Polyethylene Aluminium foil Polyester tape no braid PVC 8 4 24 Solid Bare Copper Polyethylene Unshielded PVC RJ 45 8 4 24 7 x 32 Tinned Copper Polyethylene Unshielded PVC 8 4 24 Solid Bare Copper Polyethylene Aluminium foil Polyester tape no braid PVC RJ 12 8 4 24 7 x 32 Tinned Copper Polyethylene Aluminium foil Polyester tape no b...

Page 12: ...Input Point Module AFI5100 12 Siemens Building Technologies A24205 A335 B245 doc Fire Safety Security Products 02 2005 ...

Page 13: ......

Page 14: ...sruhe www sbt siemens com 2005 Copyright by Siemens Building Technologies AG Data and design subject to change without notice Supply subject to availability Printed in the Federal Republic of Germany on environment friendly chlorine free paper Document no A24205 A335 B245 Edition 02 2005 ...