$SSHQGL[
6-
9
&*&
Annunciations 7SJ511 for LSA (DIN 19244 and according VDEW/ZVEI)
²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²²
FNo.
- Function number of annunciation
Op/Ft - Operation/Fault annunciation
C/CG: Coming/Coming and Going annunciation
V
: Annunciation with Value
M
: Measurand
LSA No.- Number of annunciation for former LSA (DIN 19244)
according to VDEW/ZVEI:
CA
- Compatible Annunciation
GI
- Annunciation for General Interrogation
BT
- Binary Trace for fault recordings
Typ
- Function type (p: according to the configured "Function type")
Inf
- Information number
¿©©©©§©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©§©©©©©§©©©§©©©©©©©©©©©©©©©©¤
Ann.LSA
VDEW/ZVEI
FNo. Meaning
OpFtNo.CAGIBTTypInf
¨©©©©ª©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©ª©©ª©©ª©©©ª©©ª©©ª©©ª©©©ª©©©
11>User defined annunciation 1
CG 24CAGIBT p 27
12>User defined annunciation 2
CG 25CAGIBT p 28
13>User defined annunciation 3
CG 26CAGIBT p 29
14>User defined annunciation 4
CG 27CAGIBT p 30
51Device operative / healthy
CG 1 GI 135 81
52Any protection operative
CG
CAGI p 18
55Re-start of processor system
C 8CA p 4
56Initial start of processor system
C
CA p 5
59Real time response to LSA
C 6
60LED Reset
C 13CA p 19
62Test mode
CG
CAGI p 21
63PC operation via system interface
CG
135 83
95Parameters are being set
CG 11CAGI p 22
96Parameter set A is active
CG
CAGI p 23
97Parameter set B is active
CG
CAGI p 24
98Parameter set C is active
CG
CAGI p 25
99Parameter set D is active
CG
CAGI p 26
110Annunciations lost (buffer overflow)
C 9 135130
112Annunciations for LSA lost
C 10 135131
113Fault tag lost
BT135136
140General internal failure of device
CG
CAGI p 47
143Failure of internal 15 VDC power supplyCG 97 GI 135163
144Failure of internal 5 VDC power supply CG 98 GI 135164
145Failure of internal 0 VDC power supply CG 99 GI 135165
154Failure in the RKA module
CG 100CAGI p 36
160Common alarm
CG
CAGI p 46
161Measured value supervision of currents CG
CAGI p 32
162Failure: Current summation supervision CG 104 GI 135182
163Failure: Current symmetry supervision CG 107 GI 135183
204Fault recording initiated via bin.input
BT135204
205Fault recording initiated via keyboard
BT135205
206Fault recording initiated via PC interf
BT135206
301Fault in the power system
CG 2 135231
302Flt. event w. consecutive no.
C
135232
501General fault detection of device
CG142 BT150151
502General drop-off of device
C 252 150152
511General trip of device
C 143 BT150161
521Interrupted current: Phase L1(I/In)
V249 150171
522Interrupted current: Phase L2(I/In)
V250 150172
¥©©©©¦©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©¦©©¦©©¦©©©¦©©¦©©¦©©¦©©©¦©©©¾