Your system has been supplied with soft PVC seal strips. Position the seal strips on the belt as
shown.
1
2
3
4
5
①
Pulley
④
Do not force seal strip against belt
②
Seal strip
⑤
Belt
③
Skirtboard
Note
Skirtboard seal stripping is not FDA or USDA approved material, and should be removed for
critical food applications.
7.3
Changing the conveyor belt
WARNING
ALWAYS STOP the belt, lock-out, and/or place a "Do Not Energize" tag on the main
disconnect before working on or around the weighfeeder.
Depending on the size of the weighfeeder, several personnel may be required to remove and
re-install the belt.
1. On enclosed models, open and remove the access and non-access side panels.
2. Mark the current position of the telescoper for reference. This will be a reference when you
re-install the belt. Loosen the telescopers to remove tension from the belt.
3. Remove support posts on the belt change side, and the belt side roller below the belt plow.
Remove tension from the belt scraper, and remove all other components for belt changing.
Note
Skirtboard removal or adjustment is not normally necessary to perform belt removal or
installation, nor is it recommended. However, if the belt has a corrugated sidewall this will be
required.
Commissioning
7.3 Changing the conveyor belt
SITRANS WW200
18
Operating Instructions, 06/2018, A5E33560654-AC