Commissioning
Check if the operating data correspond to the values stated on the rating plate. Do not modify
the Sync-FO-Multiplexer in any way.
q
Snap the mounting device of the Sync-FO-Multiplexer onto a DIN rail.
q
Connect the Sync signal to terminals “Sync-Input +” and “Sync-Input -”.
q
Connect the FO channels to the send diodes
using the F-SMA screw-type
terminals. Please tighten the F-SMA screw-type terminals carefully; in other cases, you
may destroy the thread.
q
Connect the auxiliary voltage to terminals L+ and L-.
q
Do not energize the auxiliary voltage of the Sync-FO-Multiplexer until the Sync signal and
the desired signal outputs are connected.
q
The Sync-FO-Multiplexer is ready to operate as soon as the auxiliary voltage is ener-
gized.