background image

DROK DC Multimeter

Parameter:

Test range and display format:

200141

Operating voltage range: DC 6.5-100V
Measuring voltage range: DC 6.5-100V
Rated power: 100A/10000W
Accuracy: 

1% 

Shunt: 100A/75mV
Size pof Shunt: 107x23mm /4.2" x 0.9"

Wiring diagram

:

Note:

Voltage Range: 6.5~100V (display 6.50~99.99V) 

Key  Operations:

No load (only detect the voltage, no shunt or load connected):

Load

tested device

/power supply

100A/75mV shunt

The positive and negative pole of the power supply of the 

meter can be directly connected to the positive and negative 

pole of the power supply/tested device.

With load (connected with shunt and load):

Please note that the negative pole of the DC meter cannot be

directly connected to the negative pole of the power supply end.

It should be connected to the terminals of the external shunt.

Current Range: 0~100A (display 0.00~99.99A) 
Power Range: 0~10kW 

                         within 1kW, display 0.0~999.9W; 

                         above 1kW, display 1000~9999W. 

Energy Range: 0~9999kWh 

                          within 10KWh, display 0~9999Wh; 

                          above 10kWh, display 10~9999kWh. 

   Backlight Control.

Short press the key to turn on or turn off the backlight. 

Backlight on/off status automatically saved when power off

Accumulated energy data reset.

Step 1.

  Hold press the key till the display area displays “CLr”, 

and then loose the key.

Load

tested device

/power supply

100A/75mV shunt

Front

Back