Step 2.

  At this time, the energy display area flashes to indicate

that it is at “accumulated energy data reset” status. 

Shunt range setting.

Cautions:

Recommend product 

on Amazon:

Volt Transformer Power 

Regulator Line

84.6mm

44

.6

m

m

49

.6

m

m

84.6mm

24.4mm

51mm

30mm

This module is only applicable for 6.5~100V DC power. 

Step 3.

  Short press the key, the accumulated energy will be 

cleared, and it will stop flashing and exit reset status.

Alarm voltage value setting.

Step 1.  

Hold press the key till the power display area displays 

“SET”, and then loose the key.

Step 2.  

At this time, the meter is at “alarm voltage value 

setting” mode. The voltage display area displays the present 

over-voltage alarm value, and the current display area 

displays the present under-voltage alarm value, and the least 

significant digit starts to flash.

Step 3.  

At this time, if short press the key, it will add 1 to this 

digit.

  

Step 4.  

After setting the alarm value, hold press the key till the 

screen displays “PASS” indicating set successfully and exit

the setting mode.

Please set the shunt range before using.

The attached shunt is 100A/75mV.

Step 2.  

At this time, the current display area displays “100A”. 

Short press the key, it will switch between “100A” and “50A”, 

so as to indicate whether the range of the shunt is “100A/75mV” 

or “50A/75mV”. Please note that only these two ranges of shunt 

can be applied to this meter.

Step 3.

  Hold press the key until it exits the setting mode. 

Or no key operation for 3 seconds, it will be automatically saved

and exit the setting mode.

   The voltage and current of the load cannot exceed the

    rated voltage and current of the meter. 
   Wiring order cannot be wrong. 
   Please connect the shunt to the negative terminal 

   according to the wiring diagram. If it is connected to

   the positive terminal, it will cause internal short-circuit

   or cannot function properly.
   This meter is only suitable for indoor use. Please do 

   not use it outdoor. 

Size:

If there is no key operation for 5 seconds, the accumulated 

energy will NOT be cleared, and it will stop flashing and exit 

reset status.

If no key operation for 3 seconds, it will automatically 

switch the adjusting digit. There are 6 digits to be adjusted, 

from the least significant digit to the most significant digit, from

the over-voltage value to the under-voltage value. 

            

The settable alarm voltage value range is 6.5-99.9V.    

Step 1.  

Hold press the key till the power display area displays

 “CURR”, and then loose the key.