background image

Industrial I/O-Node - ION BINARYINPUT T001 

CASTOMAT® System

 

 

Manual - English 

 

A5E02185979 

 4 / 23 

 

Preface 

 

1.1 

Purpose of this Document 

This document supports you when commissioning and using the device 

  ION BINARYINPUT T001 

of the CASTOMAT® System. 

1.2 

 Validity of this Document 

This document is valid for the following device: 

  ION BINARYINPUT T001 

1.3 

Audience 

This document is intended for personnel involved in the commissioning and using of the device: 

  ION BINARYINPUT T001 

1.4 

Standards and Approvals 

The device 

  ION BINARYINPUT T001 

meets the requirements of the CE mark. 

Extended information can be found in the appendix of this manual. 

Note 

The particularized approvals are only valid at the time, when the product is conformity marked.

 

Summary of Contents for 6AT8000-1BA00-2XA0

Page 1: ...02185979 1 23 Preface 1 Scope of Delivery 2 CASTOMAT System Product Characteristics 3 Industrial I O Node ION BINARYINPUT T001 Installation and Maintenance 4 6AT8000 1BA00 2XA0 Notes on the CE Mark 5 References 6 Appendix 7 Manual English Release 2008 09 Contact Information 8 ...

Page 2: ...equipment Qualified persons are defined as persons who are authorized to commission to earth and to tag cir cuits equipment and systems in accordance with established safety practices and standards Intended Use Please note the following Warning This device and its components may only be used for the applications described in the catalog or technical description and only in connection with devices ...

Page 3: ...nts 7 3 2 1 Hardware 7 3 2 2 Software 7 3 3 Order Numbers 7 3 4 Network Topology 8 3 5 Interfaces 9 3 5 1 Overview of Interfaces 9 3 5 2 IEEE1394a Interfaces 10 3 5 3 Power Supply Interface 11 3 5 4 Binary Interfaces 12 3 6 Indicators 13 3 7 Technical Data 14 3 8 Block Diagram 16 4 Installation and Maintenance 17 4 1 Types of Installation 17 4 2 Installation 17 4 3 Disassembly 18 4 4 Example of In...

Page 4: ...ument This document is valid for the following device ION BINARYINPUT T001 1 3 Audience This document is intended for personnel involved in the commissioning and using of the device ION BINARYINPUT T001 1 4 Standards and Approvals The device ION BINARYINPUT T001 meets the requirements of the CE mark Extended information can be found in the appendix of this manual Note The particularized approvals ...

Page 5: ...BINARYINPUT T001 3 pin plug in terminal block PHOENIX CONTACT COMBICON 3 Pin MVSTBW 2 5 3 STF 5 08 16 pin plug in terminal block PHOENIX CONTACT COMBICON 16 Pin MVSTBW 2 5 16 STF 5 08 2 2 Unpacking and Checking After unpacking please check the packet for completeness and all parts for transport damage Warning Do not use any parts that show evidence of damage ...

Page 6: ...OMAT System The ION BINARYINPUT T001 captures binary signals and transmits the measured data to a superior industrial PC via its FireWire IEEE1394a standard link with 400 Mbps The usage of the ION BINARYINPUT T001 allows the recording of 8 binary separate electrically isolated sig nals with a level of 0 24 V The maximum sample rate is up to 250 kHz per channel The device is designed for the usage ...

Page 7: ...et and USB interfaces power supply units and connecting cables depending on the used CASTOMAT System components 3 2 2 Software CASTOMAT X Tools XP Standard or Professional Edition 3 3 Order Numbers Article Order Number MLFB CASTOMAT ION BINARYINPUT T001 6AT8000 1BA00 2XA0 CASTOMAT System User Documentation 6AT8000 5AA00 0XA0 CASTOMAT X Tools XP Standard Edition 6AT8000 0AA00 1BA0 CASTOMAT X Tools ...

Page 8: ...l to the one of a bus with branching but without loops Tree topology The tree topology facilitates the building of networked systems by connecting two further nodes to each node tree topology Chain topology The chain topology enables the building of networked systems by connecting one further node to each node chain topology Caution The maximum number of nodes per bus is limited to 63 The maximum ...

Page 9: ...STOMAT System Manual English A5E02185979 9 23 3 5 Interfaces 3 5 1 Overview of Interfaces The device ION BINARYINPUT T001 provides three plugs for further CASTOMAT system components and eight inputs for binary 0 24 V signals ION BINARYINPUT T001 ...

Page 10: ...l English A5E02185979 10 23 3 5 2 IEEE1394a Interfaces At the ION BINARYINPUT T001 the IEEE1394a Interfaces P1 P2 P3 are implemented as 6 pin sockets IEEE1394a Interfaces Caution Only cables of a maximum length of 4 5 m may be connected to the IEEE1394a Interfaces ...

Page 11: ...imately 90 seconds the device starts automatically again power supply interface Caution The device ION BINARYINPUT T001 is designed for operation with safety extra low voltage This means that only safety extra low voltages SELV complying with IEC950 EN60950 VDE0805 can be connected to the power supply terminals The power supply unit for the supply of the ION BINARYINPUT T001 has to meet NEC Class ...

Page 12: ...79 12 23 3 5 4 Binary Interfaces At the ION BINARYINPUT T001 the interface to the binary 0 24 V signals CH 01 CH 08 is implemented as 16 pin socket PHOENIX MVSTBW 2 5 16 GF 5 08 binary interfaces Caution Only cables of a maximum length of 3 0 m may be connected to the binary inputs ...

Page 13: ...dition off no operating voltage blinks firmware operates Name ERR Description error indicator Color red Condition off no error on error fan if any Name LNK Description indicator for the connection to the controller Color yellow Condition off no connection to the controller on connection to the controller established blinks data exchange with the controller ...

Page 14: ...mber 3 Connector type 6 pin socket Type IEEE1394a Interface Transfer speed 400 Mbps Standard IEEE1394a Binary Interfaces CH 01 08 Number 8 Connector type 16 pin plug in terminal block Phoenix Contact Type comparator input Input voltage 48 V Input protection 60 V Insulation 0 4 kV Electrical isolation channels are electrically isolated separately Input current 2 5 mA I 3 5 mA Sample frequency 250 k...

Page 15: ...ge temperature 25 85 C Humidity rating 5 95 not condensing EMC interference emission EN 55011 Class A EMC interference immunity EN 61000 6 2 2005 Degree of protection IP20 Constructive Structure Dimensions H x W x D in mm 200 x 60 2 x 126 5 Design aluminum stainless steel Color silver Weight 1 kg Mounting DIN rail profile DIN EN 50022 35x15 thickness 2 3 mm Approvals CE EN 61000 6 4 2001 EN 61000 ...

Page 16: ...5979 16 23 3 8 Block Diagram block diagram BI 1 Opto coupler BI 2 BI 3 Opto coupler Opto coupler BI 4 BI 5 Opto coupler Opto coupler BI 6 Opto coupler BI 7 BI 8 Opto coupler Opto coupler µC Link Layer Physical Layer DPR CTRL Logic µC FPGA IEEE1394a Power Supply 24 VDC CH 01 CH 08 ...

Page 17: ...device on the DIN rail and push it down towards the DIN rail so that it snaps in Installation of electric connection cables Install the terminal block of the binary connection cables Install the plugs of the IEEE1394 connection cables Install the terminal block of the power supply connection cable installation of the ION BINARYINPUT T001 on a DIN rail Caution The spaces which are specified in chap...

Page 18: ... Disassemble the terminal block of the power supply connection cable Disassemble the plugs of the IEEE1394 connection cable Disassemble the terminal block of the binary connection cables Removal of the device from the DIN rail Push the device down against the DIN rail and hang it out disassembly of the ION BINARYINPUT T001 from the DIN rail 1 2 3 ...

Page 19: ...Note This image shows an exemplary installation Technical data subject to change 4 5 Grounding The screw on the front side of the device is provided as grounding connection 4 6 Maintenance If a fault develops please send the device to the Siemens logistics center Address SIEMENS AG I IA RETOUREN CENTER FUERTH SIEMENSSTR 2 90766 FUERTH GERMANY ...

Page 20: ...de scribed in this commissioning manual Conformity Certificates The EC Declaration of Conformity is available for the responsible authorities according to the abovementioned EC Directive at the following address SIEMENS AG I IA SE DE WUERZBURGER STR 121 90766 FUERTH GERMANY Notes for the Manufacturers of Machines This product is not a machine in the sense of the EC Machinery Directive There is the...

Page 21: ...Industrial I O Node ION BINARYINPUT T001 CASTOMAT System Manual English A5E02185979 21 23 6 References 6 1 Other Documentation CASTOMAT System User Documentation CD ...

Page 22: ...oes not contain complete detail information to the product due to reasons of clarity and can therefore exclude each thinkable case of assembly usage or the maintenance Further information is obtained from your local Siemens office and from the homepage http www siemens com castomat Technical data subject to change In cases of doubt the German document is valid ...

Page 23: ... I O Node ION BINARYINPUT T001 CASTOMAT System Manual English A5E02185979 23 23 8 Contact Information Address SIEMENS AG I IA SE DE WUERZBURGER STR 121 90766 FUERTH GERMANY Internet http www siemens com castomat ...

Reviews: