Siemens 2GF1192-8CA Installation Manual Download Page 2

 

Issued by 
Siemens Building Technologies 
Fire & Security Products GmbH & Co. oHG  
D-76181 Karlsruhe 
 
www.sbt.siemens.com 
 

© 2006 Copyright by

Siemens Building Technologies AG

Data and design subject to change without notice.

Supply subject to availability.

Printed in the Federal Republic of Germany

 on environment-friendly chlorine-free paper.

Document no. 

A24205-A336-B282

 

 

Edition 09.2006 

 

 

English

Safety 

Target group 

This installation guide is only intended for use 
by installers who have an adequate working 
knowledge of video systems! 

General safety precautions 

This guide outlines the most important 
information about the housing. It is, however, 
vital that you also refer to the full operating 
instructions. 

Scope of delivery 

 Outdoor 

housing 

 Safety 

screwdriver 

  Gland with two-entry rubber 

  Additional one-entry & four-entry rubbers 

 Y 

cable 

 Sealed 

pins 

Installation 

Installing dome in housing  
A) Without PG gland 

Wall mount including junction box 

1.  Attach the video cable (

11

) (included with 

the dome housing) to the video connector 
on the dome base (

1

). 

2.  Connect the communication cables (

13

directly to the appropriate terminals 
(indicated by colour) on the dome base 
(see Fig.

 D

). 

3.  Connect the power-in cables (

12

) directly 

to the termination of power on the dome 
base (see Fig. 

D

). 

4.  Tighten the fixing screw to fix the speed 

dome base into the housing (see Fig. 

A

 

magnifying picture). 

5.  Connect the support wire (

3

) to the hook 

(

2

) of the dome base (see Fig. 

A

). 

6.  To lock the dome drive (

4

) to the dome 

base, line up the notch with the label and 
turn to the right with both hands  
(see Fig. 

B

). 

7.  Holding the dome casing (

6

) to maintain 

the matched position, tighten the 3 
screws (

7

) with a screwdriver (

8

) and lock 

the dome cover to the unit housing (

9

(see Fig. 

C

). 

8.  The installation is now completed. 
 

B) With PG gland 

Simple wall and pendant mount 

1.  Separate the sealing nut & two-entry 

rubber from the outdoor housing (Fig. 

G

), 

and then take out the speed dome cables 
(see Fig. 

D

: 10, 11, 12, 13) from the 

outdoor housing. 

2.  Connect the Y cable (the ends with 

contact shoes) to the power terminal; the 
other end is for the heater connector (see 
Fig. 

F

). 

3.  Replace the two-entry rubber with the 

four-entry/one-entry rubber based on the 
wiring (see Fig. 

G

). 

 

NOTE: 

We recommend to use a PG gland for all 
kinds of mounts to ensure improved IP66 of 
the housing. 
Connect the lines from the field to the power 
terminal, BNC connector, Alarm IN/Out & 
Data at the dome, pulling the cable through 
the one-/four-entry rubber. 

4.  Screw on the sealing nut. 
5.  Make sure that the gland is fixed properly 

to keep humidity out of the housing and 
ensure IP66. 

Operation and storage 

Do not operate or store the unit : 

  At extremely hot or cold places. 

  Close to sources of strong magnetism. 

  Close to sources of powerful 

electromagnetic radiation such as radios 
or TV transmitters. 

  Where exposed to mechanical vibrations. 

  Close to fluorescent lamps or objects 

reflecting light. 

  Under unstable or flickering light sources. 

Technical data 

Height 345 

mm 

Diameter 240 

mm 

Weight 4.0 

kg 

(max.) 

Bubble clear 
Operating temperature 

-30 – +50 °C 

Storage temperature 

-40 – +60 °C 

Relative humidity 

0 – 90% 

Heater switch temperature 

On:   +4 °C 
Off: +16 °C 

Heater: 24 

VA 

  Input voltage 

24 V AC 

  Power consumption 

26 VA 
housing only 

Protection type 

IP66 

Bubble impact resistance 

800 kg 

 

 

 

 

 

 

CAUTION 

1. 

Ensure that the safety wire (located in the dome base) is engaged. 

2. 

Align notch with "OPEN" arrow and turn dome until notch meets arrow in "LOCKED" position. 

3. 

When using outdoor housing, ensure that safety-wire of dome housing is always fixed firmly to the 
mount to prevent unit from falling down. 

4. 

Check assembly by pulling. Assembly should

 

not come apart. 

 

 

 

English  

 

 

For more detailed information please refer to the Instruction Manual for ¼" Speed Dome Cameras. 

Deutsch  

 

 

Nähere Informationen hierzu finden Sie im Installationshandbuch für ¼" Speed Dome Cameras. 

Français  

 

 

Veuillez consultez le guide d'opération des cameras ¼" Speed Dome pour d’information plus détaillée.

Nederlands  

 

 

Uitgebreide Informatie find u in het instruktie handboek voor ¼ Speed Dome Kameras. 

Italiano  

 

 

Per maggiori dettagli si rimanda al manuale specifico di istruzione della telecamera Speed Dome ¼". 

Polski  

 

 

Wi

ę

cej informacji zawiera instrukcja obs

ł

ugi zintegrowanej kamery szybkoobrotowej ¼”. 

Svenska  

 

 

För ytterligare information hänvisas till installationsmanualen för ¼" Speed Dome Cameras. 

Español  

 

 

Por favor, para una información más detallada, consulte con el manual de instrucciones de los domos 
de alta velocidad de ¼”. 

Portugues  

 

 

Ou uma informação mais detalhada consulta por favor ao Manual do utilizador Câmaras de Tecto de 
Alta Velocidade ¼ polegada. 

Č

esky  

 

 

Pro podrobn

ě

jší informace se prosím podívejte do návodu pro obsluhu ¼" Speed Dome kamery. 

 

Reviews: