background image

Siemens ST 80 · 2006

2/121

Operator Control and Monitoring Devices

Panels — 270 series

SIMATIC OP 270

2

Technical specifications

 

SIMATIC 
OP 270 
5,7“ Color 
STN Display

SIMATIC 
OP 270 
10,4“ Color 
STN Display

Display

 

• Display type

STN liquid 
crystal display 
(LCD)

STN liquid 
crystal display 
(LCD)

• Size

5.7"

10.4"

• Resolution (W x H in pixels)

320 x 240

640 x 480

• Colors

256 colors

256 colors

• MTBF of background lighting

(at 25 °C)

approx. 40,000 
hours

approx. 60,000 
hours

Operating mode

 

• Control elements

Membrane 
keyboard

Membrane 
keyboard

• Operating options

Key

Key

• Function keys, programmable

24 function 
keys, 
18 with LEDs

36 function 
keys, 
28 with LEDs

• Membrane keyboard

Yes

Yes

• System keys

36

38

• Numeric/alphanumeric input

Yes/Yes

Yes/Yes

• External mouse/keyboard/bar-

code reader

USB/USB/USB

USB/USB/USB

Processor/HW

 

RISC 32 bits, 
180 MHz

RISC 32 bits, 
180 MHz

Operating systems

 

Windows CE

Windows CE

Memory

 

• Type

Flash/RAM

Flash/RAM

• Usable memory for project data

2028 KB user 
memory/with-
out additional 
memory for 
options

2028 KB user 
memory/with-
out additional 
memory for 
options

Interfaces (some only as options)

 

• Interfaces

2 x RS232, 
1 x RS422, 
1 x RS485 
max. 12 Mbit/s

2 x RS232, 
1 x RS422, 
1 x RS485 
max. 12 Mbit/s

• CF card slot

1 x CF card slot

1 x CF card slot

• USB (universal serial bus)

1 x USB

1 x USB

Supply voltage

 

• Supply voltage

24 V DC

24 V DC

• Permissible range

+18 to +30 V 
DC

+18 to +30 V 
DC

• Rated current

0.6 A

0.6 A

• Output

15 W

15 W

• UPS can be connected (serial)

Yes

Yes

• Backup battery

Optional 3.6 V

Optional 3.6 V

Clock

Hardware 
clock, battery-
backed and 
synchronized

Hardware 
clock, battery-
backed and 
synchronized

SIMATIC 
OP 270 
5,7“ Color 
STN Display

SIMATIC 
OP 270 
10,4“ Color 
STN Display

Degree of protection

• Front

IP65, 
NEMA 4, 
NEMA 4x, 
NEMA 12; 
(when 
mounted)

IP65, 
NEMA 4, 
NEMA 4x, 
NEMA 12; 
(when 
mounted)

• Rear

IP20

IP20

Certification 
(some only as options)

CE, GL, ABS, 
DNV, LRS, FM 
Class I Div. 2, 
UL, cULus, 
EX zone 2/22, 
C-TICK

CE, GL, ABS, 
DNV, LRS, FM 
Class I Div. 2, 
UL, cULus, 
EX zone 2/22, 
C-TICK

Mechanical components/
dimensions 

• Front panel W x H (mm)

308 x 204

483 x 310

• Mounting cutout/depth W x H x D 

(mm)

282 x 178/
59 mm depth 
of unit

436 x 295/
55 mm depth 
of unit

• Weight

1 kg

6 kg

Ambient conditions

 

• Max. relative humidity (in %)

90%

90%

• Mounting position 

Vertical

Vertical

- Max. permissible angle of 

inclination without external fan

+/- 35°

+/- 35°

• Temperature 

- Operation (vertical installation)

0 to +50 °C

0 to +50 °C

- Operation

(max. angle of inclination)

0 to +35 °C

0 to +35 °C

- Transportation and storage

-20 to +60 °C

-20 to +60 °C

Expansions for operator-process 
communication 
(may only be an option)

 

• DP direct LEDs

(LEDs as S7 output I/O)

F1...F8, 
K1...K10

F1...F12, 
K1...K16

• DP direct keys 

(buttons as input peripherals)

F1...F14, 
K1...K104 byte 
or coded

F1...F20, 
K1...K165 byte 
or coded

Peripherals/applications/options 

• I/O

Printer, bar-
code reader

Printer, bar-
code reader

• Applications/options

(with ProTool)

ProAgent

ProAgent

Configuring

 

• Configuration tool

ProTool

ProTool

• Configuration tool

WinCC flexible

WinCC flexible

© Siemens AG 2007

Summary of Contents for 270 series

Page 1: ... Standard Windows storage format CSV for archives and recipes for further processing using standard tools e g MS Excel Optional Ethernet TCP IP for centralized data management and project management connection of PLC to SIMATIC S7 when configuring with WinCC flexible Application The SIMATIC TP 270 Touch Panels can be used in all applica tions in which operator control and monitoring of machines an...

Page 2: ...functions including linking to ProTool variables compari son operations loops etc Help texts for process diagrams messages and variables Mathematical functions Limit value monitoring for reliable process control of inputs and outputs Permanent window permanent display area for the output of information that is not specific to the particular display e g important process vari ables date and time Si...

Page 3: ...d monitoring as well as communication between different SIMATIC HMI systems see WinCC flexible RT options WinCC flexible Sm rtService Remote monitoring and servicing of machines plants over the Internet intranet see WinCC flexible RT options Integration The TP 270 can be connected to SIMATIC S7 200 300 400 SIMATIC WinAC Software Slot PLC SIMATIC S5 SIMATIC 505 SINUMERIK SIMOTION Non Siemens contro...

Page 4: ...P65 NEMA 4 NEMA 4x NEMA 12 when mounted Rear IP20 IP20 Certification some only as options CE GL ABS DNV LRS FM Class I Div 2 UL cULus EX zone 2 22 C TICK CE GL ABS DNV LRS FM Class I Div 2 UL cULus EX zone 2 22 C TICK SIMATIC TP 270 5 7 Color STN Display SIMATIC TP 270 10 4 Color STN Display Mechanical components dimensions Front panel W x H mm 212 x 156 335 x 275 Mounting cutout depth W x H x D m...

Page 5: ...ead e g in MS Excel MS Access External evaluation Can be read e g in MS Excel MS Access etc Can be read e g in MS Excel MS Access etc Size of archive Dependent on the memory space avail able on the external card stick or spare hard disk memory via the network drive Dependent on the memory space avail able on the external card stick or spare hard disk memory via the network drive Online evaluation ...

Page 6: ... TP 270 5 7 Color STN Display SIMATIC TP 270 10 4 Color STN Display Functionality under ProTool continued Archiving Number of archives per project 20 20 Number of process tags per archive 20 20 Number of entries per archive 500 000 500 000 Archive types Short term archive sequence archive mes sage archive process value archive Short term archive sequence archive mes sage archive process value arch...

Page 7: ...with WinCC flexible WinCC flexible ProAgent See Section 4 WinCC flexible Sm rtAccess See Section 4 WinCC flexible Sm rtService See Section 4 Documentation to be ordered separately Operating Instructions TP 270 OP 270 and MP 270B WinCC flexible German 6AV6 691 1DD01 0AA0 English 6AV6 691 1DD01 0AB0 French 6AV6 691 1DD01 0AC0 Italian 6AV6 691 1DD01 0AD0 Spanish 6AV6 691 1DD01 0AE0 User Manual WinCC ...

Page 8: ...le user manuals manuals and communication manuals for SIMATIC HMI Accessories CF cards CF card 128 MB A 6AV6 574 2AC00 2AA0 Backup battery W79084 E1001 B2 Lithium battery DC 3 6 V 1 7 Ah for TD17 OP17 OP25 OP27 OP 270 OP35 OP37 TP27 TP 270 TP37 MP 270 MP 270B MP 370 Accessories for supplementary ordering Cover foil to protect the touch front against fouling scratching set of 10 for TP 270 6 6AV6 5...

Page 9: ...Windows storage format CSV for archives and recipes for further processing using standard tools e g MS Excel Optional Ethernet TCP IP for centralized data management and project management connection of PLC to SIMATIC S7 when configuring with WinCC flexible Application The OP 270 Operator Panels can be used in all applications in which operator control and monitoring of machines and installa tions...

Page 10: ...rts operator prompting from the PLC Visual Basic Script flexibility through the implementation of new functions including linking to ProTool variables compari son operations loops etc Help texts for process diagrams messages and variables Mathematical functions Limit value monitoring for reliable process control of inputs and outputs Permanent window permanent display area for the output of inform...

Page 11: ...oring as well as communication be tween different SIMATIC HMI systems see WinCC flexible RT options WinCC flexible Sm rtService Remote monitoring and service of machines plants over the Internet Intranet see WinCC flexible RT options Integration The SIMATIC OP 270 Operator Panels can be connected to SIMATIC S7 200 300 400 SIMATIC WinAC Software Slot PLC SIMATIC S5 SIMATIC 505 SINUMERIK SIMOTION No...

Page 12: ...ated current 0 6 A 0 6 A Output 15 W 15 W UPS can be connected serial Yes Yes Backup battery Optional 3 6 V Optional 3 6 V Clock Hardware clock battery backed and synchronized Hardware clock battery backed and synchronized SIMATIC OP 270 5 7 Color STN Display SIMATIC OP 270 10 4 Color STN Display Degree of protection Front IP65 NEMA 4 NEMA 4x NEMA 12 when mounted IP65 NEMA 4 NEMA 4x NEMA 12 when m...

Page 13: ...isplay SIMATIC OP 270 10 4 Color STN Display Archiving Number of archives per project 20 20 Number of process tags per ar chive 0 0 Number of entries per archive 10 000 10 000 Archive types Sequence archive short term archive alarm log pro cess value archive Sequence archive short term archive alarm log pro cess value archive Memory location CF card Ether net CF card Ether net Data storage format ...

Page 14: ...ides analog dis plays hidden buttons Diagrams bar graphs slides analog dis plays hidden buttons SIMATIC OP 270 5 7 Color STN Display SIMATIC OP 270 10 4 Color STN Display Variables 2048 2048 Archiving Number of archives per project 20 20 Number of process tags per ar chive 20 20 Number of entries per archive 500 000 500 000 Archive types Short term archive sequence archive mes sage archive process...

Page 15: ...CC flexible Communication German 6AV6 691 1CA01 0AA0 English 6AV6 691 1CA01 0AB0 TP OP 270 and MP 270B ProTool Manual German 6AV6 591 1DC20 0AA0 English 6AV6 591 1DC20 0AB0 French 6AV6 591 1DC20 0AC0 Italian 6AV6 591 1DC20 0AD0 Spanish 6AV6 591 1DC20 0AE0 ProTool User Manual for config uring Windows based systems German 6AV6 594 1MA06 1AA0 English 6AV6 594 1MA06 1AB0 French 6AV6 594 1MA06 1AC0 Ita...

Page 16: ...ication or option for the products described here Then look up Customized products where you will find information about additional sector specific products that can be ordered as well as about options for customer specific modification and adaptation Panel cutout B x H in mm 282 x 178 308 280 204 59 6 176 Dimensions in mm G_ST80_XX_00056 Panel cutout B x H in mm 436 x 295 482 6 431 6 310 3 58 6 9...

Reviews: