3

Target group of this documentation

• This documentation is intended for use by specialists and end users.
• All work described in this document is to be performed by experienced professionals with training and practice in the 

installation, commissioning and maintenance of ventilation units. Safe and proper assembly of this unit is not possible without 
expert knowledge.

• All instructions on operation and maintenance described here are intended for end users.
• After the successful assembly and installation, the installation company is committed to handing over the operating 

instructions to the end user.

Intended use

• Use the AEROTUBE exclusively for the ventilation of closed rooms (kitchen, bathroom, living rooms and bedrooms).
• The AEROTUBE is not suitable for dehumidification (e.g. for the drying of new buildings).
• The unit must always be installed by an experienced specialist, in accordance with the installation and planning documents 

of SIEGENIA. The installation instructions in this document must be complied with at all times.

• Be sure to attach an original SIEGENIA weather grille to protect the device from the outside.
• Do not install the unit in contaminated rooms and ensure that no hazardous substances can be drawn in.
• Do not use the AEROTUBE in environments with corrosive or explosive atmospheres (dust, vapour or gas).
• The unit is not suitable for use in swimming pools and/or damp locations.
• The AEROTUBE must be mounted in a vertical position. Mounting on inclines (e.g. walls and ceilings), is not permissible.
• If the unit is to be used in a room with a heating unit that draws air from the room, prior authorisation must be obtained from 

the proper authorities, such as the officially appointed district chimney sweep.

• Only operate and/or store the AEROTUBE at temperatures between -15 °C and +40 °C.
• Use the unit only with original accessories from SIEGENIA.
• Observe the safety regulations for operating electrical equipment and, if necessary, for ladders, steps and work overhead or 

at certain heights.

• Use the unit only when it is in a technically sound condition. 
• Do not modify the unit's components in any way.
• Please do not put any objects on top of the unit.
• Do not use the device as a seat.
• Make sure that air can flow in and out at the two outer sides without impedance. Do not hang any textiles or paper or similar 

items over the air inlet and outlet ports and do not place any objects directly in front of or beside the unit. Do not insert any 
objects into the openings of the unit.

• Do not remove any covers or unit components that are not defined in the "Maintenance" chapter. Do not remove the cover of 

the connecting clamps inside the unit.

• The unit must be checked by a specialist in the event of a fault.

Dimensions

• All the dimensions in this documentation are specified in mm.

Summary of Contents for Aeruotube AZ smart

Page 1: ...ventilator with optional supply and exhaust air function heat recovery and temperature humidity sensor AEROTUBE WRG smart AEROTUBE AZ smart Window systems Door systems Comfort systems ORIGINAL OPERAT...

Page 2: ...delivery equipment 5 Installation 6 Unit function 11 Operation general 12 Operation via button on the device 13 Operation via smartphone or tablet 13 Care and maintenance 14 Accessories 19 Rectificati...

Page 3: ...with corrosive or explosive atmospheres dust vapour or gas The unit is not suitable for use in swimming pools and or damp locations The AEROTUBE must be mounted in a vertical position Mounting on incl...

Page 4: ...All pole safety isolation is required if the customer is routing the mains cable Current local regulations such as those of the VDE in Germany must be observed Relevant country specific regulations w...

Page 5: ...accumulator 9 Ventilation pipe 160 10 Bag of screws 4 screws and dowels 11 Translation of the original operating instructions 12 Weather grille optional see accessories page 19 Function Heat recovery...

Page 6: ...l objects Air conditioning units Wireless devices e g radio telephones baby monitors Bluetooth loudspeakers etc WLAN networks on the same wireless channels e g the neighbour s WLAN router If energy ca...

Page 7: ...discharging outwards the hole must have an incline of 0 5 2 However the slope must not exceed 3 as this would make it impossible to remove the pipe inset from the ventilation pipe for maintenance pur...

Page 8: ...iginal operating instructions 11 2016 5 Shorten pipe 6 Insert pipe Attention The pipe must be at least 270 mm long X X 7 Insulate pipe according to requirement 8 Seal pipe Inside airtight seal Outside...

Page 9: ...ng instructions AEROTUBE 11 2016 9 9 Push complete pipe inset with mounting cover into the pipe 10 Plaster the wall 11 Remove front panel 12 Remove electronics cover 13 Remove mounting cover 14 Positi...

Page 10: ...016 15 Fix filter casing into place 16 Connect mains cable 4x N L1 PE 17 Clip electronic cover into place 18 Connect axial ventilator 19 Clip front panel into place 20 Position the weather grille scre...

Page 11: ...rt The warm exhaust air is absorbed by the ceramic heat accumulator in supply and exhaust air operation The stored heat is transferred to the supply air and thus proceeds into the room preheated Opera...

Page 12: ...LED 3 lights up green Automatic mode Blower level 1 LED 2 lights up green LED 3 lights up green Automatic mode Blower level 2 LED 1 lights up green LED 2 lights up green LED 3 lights up green Automat...

Page 13: ...timers can be programmed free definition of starting time running time week days mode of operation and blower performance Filter change indicator and reset of the filter change indicator after filter...

Page 14: ...e AEROTUBE do not allow liquids to get inside the unit Never use cleaning agents that are aggressive or contain solvents or sharp edged objects as these may damage the surfaces of the casing Never cle...

Page 15: ...to pipe inset falling out Ensure that the pipe inset does not fall down Proceed with caution 1 Remove front panel 2 Remove complete pipe inset 3 Open pipe inset Attention Do not bend the retaining cl...

Page 16: ...1 2016 4 Remove filter and ceramic heat accumulator 5 Dispose of the old filter 6 Clean ceramic heat accumulator and leave to dry 7 Position ceramic heat accumulator in pipe inset 8 Clamp new filter b...

Page 17: ...ting instructions AEROTUBE 11 2016 17 10 Push complete pipe inset into pipe 11 Connect axial ventilator 12 Clip front panel into place Attention The cable outlet in the front panel must be on the slid...

Page 18: ...ns 11 2016 Filter replacement AEROTUBE AZ smart 1 Remove front panel 2 Remove filter 3 Dispose of the old filter 4 Insert new filter 5 Clip front panel into place Attention The cable outlet in the fro...

Page 19: ...ion AEROTUBE shows no reaction when key is pressed No power supply Check power supply Wiring wrong defective or cable defective Have the wiring checked by a qualified electrician Power supply defectiv...

Page 20: ...SEV Energy efficiency class SEV class according to climatic zone warm average cold 17 62 kWh m a E 42 15 kWh m a A 84 96 kWh m a A 10 99 kWh m a E 25 36 kWh m a C 50 44 kWh m a A d Type WLA ZLA WLA E...

Page 21: ...Original operating instructions AEROTUBE 11 2016 21 Dimensions 63 259 279 259 279...

Page 22: ...rtly dismantled and the defect is due to the changes made Exclusion of liability The product and its components are subject to stringent quality controls As a result they function reliably and safely...

Page 23: ...14 EN 62233 2008 c 2014 53 EC RED Directive c1 Electromagnetic compatibility EN 301489 1 V 1 9 2 EN 301 489 17 V 2 2 1 EN 61000 3 2 2014 EN 61000 3 3 2013 c2 Electrical safety Establishment of informa...

Page 24: ...85 4861080 China Phone 86 316 5998198 France Phone 33 3 89618131 Germany Phone 49 271 39310 Great Britain Phone 44 2476 622000 Hungary Phone 36 76 500810 Italy Phone 39 02 9353601 Poland Phone 48 77 4...

Reviews: