Assembly and operating instructions
AEROMAT 80
5
08.2021
Installation
Prerequisites for installation
• The position from which the outdoor air is drawn in must be selected in such way that any nearby emission sources have
as little impact as possible on the quality of the air being drawn in.
• Installation options:
installation in glazing rebate
AEROMAT
80
installation in impost
AEROMAT
80
Installation sequence
1. Carefully remove AEROMAT 80 from the packaging. We recommend placing the unit on a soft surface (e.g. cardboard
or blanket) during installation.
2. Close the fan flap to prevent contamination (e.g. dust) from entering the unit during installation.
3. Install the AEROMAT 80 in its intended installation position and seal it in accordance with the installation directives
applicable on site.
4. Check AEROMAT 80 for cleanliness prior to starting it up. If necessary, thoroughly clean the unit as described in our
operating instructions.