Installation and operating instructions
AEROMAT 150
03.2020
5
Mains supply
The AEROMAT 150 is connected directly to the 230 V AC mains power supply using an external switch.
Exposed electrical components.
Risk of fatal injury from electric shock or fire.
›
Work on a 230 V AC mains power supply may only be performed by a qualified electrician.
›
All work on the 230 V AC mains power supply must be carried out in compliance with the current German VDE
regulations (e.g. VDE 0100) and any relevant country-specific requirements.
›
Switch off or unscrew the fuses.
Important:
If the AEROMAT 150 is connected directly to the 230 V AC mains power supply, a mains isolator must be
installed by the customer.
›
Wire the circuit according to this circuit diagram
Connection Type DK
Switch assignment
S1 Opening and closing of the locking plate
PE
1
2
3
5
4
6
S1
PE
N
L1
blue 1
brown 2
black 3
Unit function
Pressure differential operation
• The room is ventilated as the indoor and outdoor air pressures are equalised (pressure differential). As this happens, the
air normally flows from outside into the room.
• The air flow into the room varies as the wind pressure changes with the weather.
Operation
1
2
Type DD
: The rotary knob allows you to open and close the locking plate. You may continuously adjust the required airflow
between both end positions of the rotary knobs.
Type DK
(with 5-wire connecting cable): The locking plate may only be opened and closed by external switches, e.g. AF1,
or controlled via external units.
Locking plate
Rotary knob