background image

10

Last update: 01.08.2013

Automated latch release

Assembly instructions

Liability

Intended use

Any use of this product that is not in accordance with its intended use, or any adaptation of or modification to the product 
and its associated components for which our express consent has not been obtained, is strictly prohibited. We accept no 
liability whatsoever for any material losses or injury to people caused by failure to comply with this stipulation.

Product liability

Our products are warranted – subject to correct installation and proper use – for a period of one year from the date of re-
ceipt by a company (according to our general terms and conditions) or as otherwise agreed, and for a period of two years 
for end consumers, in accordance with statutory provisions. As part of our ongoing improvements, we reserve the right to 
replace individual components or entire products. Consequential losses resulting from defects are excluded from the war-
ranty within the limits of the law. The warranty shall become void if modifications that are unauthorized by us or have not 
been described in this documentation are performed on the product and/or individual components, or if the product and/or 
individual components is/are dismantled or partly dismantled, and the defect is due to the changes made.

Exclusion of liability

The product and its components are subject to stringent quality controls. As a result, they function reliably and safely when 
used correctly. Our liability for consequential losses and/or claims for damages is excluded, except in the case of wilful mis-
conduct or gross negligence, or where we are responsible for injury to life, limb or health. Strict liability under the German 
Product Liability Act (Produkthaftungsgesetz) remains unaffected. Liability for the culpable violation of significant contractual 
obligations also remains unaffected; liability in this case is limited to losses that are specific to the contract and that could 
have been foreseen. The above regulations do not imply a change in the burden of proof to the detriment of the consumer.

Environmental protection

Although our products do not fall within the scope of the German Electrical and Electronic Equipment Act (ElektroG), KFV 
will continue to meet the requirements of this Act and will endeavour to completely eliminate the use of substances that are 
hazardous to the environment as soon as this becomes technically feasible. Electrical products should not be disposed of as 
household waste.

Feedback on documentation

We welcome your comments and suggestions on how to improve our documentation. Please send us your feedback by e-
mail to [email protected].

We, KFV KG, declare under our own responsibility that this product complies with the provisions of 
Directives 2008/108/EC and 2006/95/EC of the Council of the European Union.

EU Declaration of Conformity

Technical specifications

Relative humidity

20 % bis 80 %

Ambient temperature in door

-- 10 bis + 45 °C

Dimensions

Width 16 mm, length approx. 252 mm, depth 49 mm + width of face plate

Supply voltage

24 V DC max. 500 mA

Cable types

Type

LIYCY

Ambient temperature, non-fixed

-- 5 bis + 50 °C

Ambient temperature, fixed

-- 20 bis + 70 °C

Summary of Contents for KFV Genius

Page 1: ...Window hardware Assembly instructions Automated latch release Automatic door lock Sliding door hardware Ventilation and building technology Door hardware...

Page 2: ......

Page 3: ...se 2 Improper use 2 Safety notes 2 Explanation of symbols 2 Installation 3 Connections 4 Cable links 6 Fitting an internal release push button optional 7 Fitting the infra red eye optional 7 Wiring di...

Page 4: ...the automated latch release only when it is in a technically sound condition Do not modify the unit s components in any way U Use the automated latch release only with genuine KFV accessories Imprope...

Page 5: ...onnected to one KFV access control wireless transponder infra red or ngerprint scanner system U The power supply comes with a permanent connection A easily accessible means of disconnecting it must be...

Page 6: ...ted latch release connections Cable types Type F Always used together with type B 0 1 2 3 4 7 Cable no Band colour Cable colour Function 0 Black Grey 1 Brown Yellow 2 Red White Operating voltage 24 V...

Page 7: ...0 1 2 3 4 7 0 1 4 7 4 4 Cable plugs for the automated latch release U To facilitate installation of the automated latch release the plug can be removed by pulling it upwards U There are letters on the...

Page 8: ...casing is tted in the door frame or leaf U Allows the door leaf to be unhinged where cable types B F are used Fig 10 Concealed cable link not disconnectable This cable link is used for routing cables...

Page 9: ...rs from operating the push button from the outside it should be ensured that any glass panes and in ll panels in the door are suitably burglar resistant The infra red eye acts as a receiver for the in...

Page 10: ...V DC 2 3 4 24VDC 2 4 3 5 6 7 8 1 No Description 1 230 V AC supply line L N PE 2 Power supply 3 Wireless receiver optional 4 External unlocking optional 5 Line length max 50 metres external unlocking...

Page 11: ...1 DSP 30 24V DC Kl 4 Fl 24 V DC 2 3 1 No Description 1 230 V AC supply line L N PE 2 Power supply 3 Wireless receiver optional 4 External unlocking optional 5 Line length max 50 metres external unlock...

Page 12: ...or consequential losses and or claims for damages is excluded except in the case of wilful mis conduct or gross negligence or where we are responsible for injury to life limb or health Strict liabilit...

Page 13: ...11 Last update 01 08 2013 Assembly instructions Automated latch release ENGLISH...

Page 14: ...larus Phone 375 17 312 1168 Benelux Phone 32 9281 1312 China Phone 86 316 5998198 France Phone 33 38961 8131 Germany Phone 49 271 3931 0 Great Britain Phone 44 2476 622000 Hungary Phone 36 76 500810 I...