Siebert SX602 series Operating Instructions Manual Download Page 9

 

BAL SX602 PFN RT  

9/36 

 

Pos :  13 /Si ebert /Bedi enungsanlei tungen/ Seri e SX502 /  SX602/ Ger ät ebesc hrei bung/Ü BS  G erät ebesc hr eibung  @  0\ mod_1317299752517_48. doc x  @  2907 @  1 @  1 

 

Unit description 

Pos :  14 /Si ebert /Bedi enungsanlei tungen/ Seri e SX502 /  SX602/ Ger ät ebesc hrei bung/G elt ungsbereic h/ SX602  Gel tungsbereic h  PFN RT  @  3\ mod_1465903582173_48.doc x @  25860 @  2 @  1 

 

Model designation 

This manual applies to units with the following model designation (x = the 'x's in the model designation 
indicate the size and design of the units see Chapter 14): 

SX602-xxx/xx/xx-xxx/xx-YP 

Pos :  15 /Si ebert /Bedi enungsanlei tungen/ Seri e SX502 /  SX602/ Ger ät ebesc hrei bung/G eräteauf bau/ SX602 G erät eaufbau PFN RT  @  3\ mod_1465903805669_48. doc x  @  25867 @  2  @  1 

 

Unit construction 

The following figure shows model type SX602-10/10/xx-xxx/xx-xx as example for the other model 
types. The front frame of the housing is locked with quick-action releases. When opening the unit the 
front frame hinges downward. 

 

The following figure shows the unit when open. 

 

 Central Processing Unit 

 Power supply unit 

 Connector plug for power supply 

 Matrix modules 

 Lower housing section 

 Housing front frame 

Units with double-sided display show the same information on the front and on the rear side. 

Pos :  16 /Si ebert /Bedi enungsanlei tungen/ Seri e SX502 /  SX602/ Ger ät ebesc hrei bung/ Prinzipschalt bild/ Prinzi psc haltbil d  neu/ Prinzi psc halt bild SX502  PFN RT , SX602  PFN RT  @  2\ mod_1408012971720_48.doc x @  9128  @  2 @  1 

 

Summary of Contents for SX602 series

Page 1: ...erie SX502 SX602 Titelseiten SX602 PFN RT 3 mod_1465903296097_48 docx 25854 1 Series SX602 Alphanumeric large size displays with Profinet IO RT interface Operating instructions Pos 3 Siebert Seitenumb...

Page 2: ...roup com FRANCE Siebert France Sarl 4 rue de l Abb Louis Verdet F 57200 Sarreguemines P O Box 90 334 F 57203 Sarreguemines C dex Phone 33 0 3 87 98 63 68 Fax 33 0 3 87 98 63 94 email info fr siebert g...

Page 3: ...siebert group com Siebert LRD and XC Board are registered trademarks of Siebert Industrieelektronik GmbH All other product names mentioned herein may be trademarks or registered trademarks of their re...

Page 4: ...tion 9 Unit construction 9 Principle circuit diagram 10 Central Processing Unit 11 Profinet IO interface 11 Serial Interface 11 Function inputs 12 Menu display 12 Status indicators 12 Battery 13 Power...

Page 5: ...types 19 Commands 19 Table of commands 19 Display dynamic text 21 Static texts 21 Inserting variables 21 Deleting text 21 Flashing 21 Marquee text 22 Forced line break 22 Character set 22 LED color 22...

Page 6: ...aracter table 28 13 Technical data 29 Unit properties 29 Housing colors 29 Front frame 29 Ambient conditions 30 Max power consumption 30 Screw type terminals 30 Fixed text memory 30 Marquee 30 Real ti...

Page 7: ...ns The repair and replacement of components and modules may only be carried out by the manufacturer for safety reasons and due to the required compliance with the documented unit properties The units...

Page 8: ...o prevent interference This applies especially to unshielded operating voltage cables Shielded cables are also to be kept short due to any interference which might be emitted by the shielding Neither...

Page 9: ...r tebeschrei bung Ger teaufbau SX602 Ger teaufbau PFN RT 3 mod_1465903805669_48 docx 25867 2 1 Unit construction The following figure shows model type SX602 10 10 xx xxx xx xx as example for the other...

Page 10: ...BAL SX602 PFN RT 10 36 Principle circuit diagram Central Processing Unit Power supply unit Power supply Display Battery Sub D connector serial interface Function input Status indicato...

Page 11: ...ungen Seri e SX502 SX602 Ger tebeschrei bung Schnittstellen Seriell Serielle Schni ttstelle SX502 ETH IP IBSPDGWY MDBTC P MD BTCPGWY DVN PFB PFN RT SX602 PFN RT 2 mod_1408019069537_48 docx 9211 2 1 Se...

Page 12: ...he following status messages may appear on the menu display The display was not assigned with a name yet The display was not assigned with an IP address yet Display is ready for Profinet In programmin...

Page 13: ...SX502 DVN ETH ETH IP MD B IBSPDGWY MDBTC P MD BTCPGWY PFB PFN IRT s u 2 mod_1408356423444_48 docx 9487 2 1 Battery The lithium battery type CR2032 provides a power reserve for the real time clock It...

Page 14: ...eichendarstellung SX602 Propor tionalschrift PFN RT 3 mod_1465908678786_48 docx 25954 2 1 Proportional lettering The character sets Acala 7 and Acala 7 extended display the characters in non proportio...

Page 15: ...Pos 35 Si ebert Bedi enungsanlei tungen Seri e S302 SX302 SX502 SX602 berei nsti mmung en Konfigurati on Gr ossanzeigen brei nsti mmung versch Serien GSDM L Datei SX502 SX602 GSDML D atei PFN RT 2 mod...

Page 16: ...SX602 PFN RT 0 mod_1322732081577_48 docx 3663 1 The units can display dynamic and static texts Dynamic texts can be changed while the unit is running They are generated from within the process and hav...

Page 17: ...2 PFN R T 2 mod_1408024333166_48 docx 9383 2 1 Input Output data bytes The number of output data bytes is fixed on two Pos 45 Si ebert Bedi enungsanlei tungen Seri e SX502 SX602 Betriebsarten Betriebs...

Page 18: ...ng settings have to be made in the menu Pos 53 Si ebert Bedi enungsanlei tungen Seri e SX502 SX602 Betriebsarten Betriebsart Dynamische und statische Texte Daten bertragung D aten bertr agung SX502 PF...

Page 19: ...y are generated from within the process and are sent to the display via the PROFINET interface Static texts cannot be changed while the unit is running They are compiled using the PC tool Display Mana...

Page 20: ...ting date DA Current date four digit year TT MM JJJJ 24 DB Current date two digit year TT MM JJ 25 DD Current day TT 26 DM Current month MM 27 DY Current year four digit JJJJ 28 DZ Current year two di...

Page 21: ...to the display and subsequent insertion of just the appropriate characters variables to update the variable text components In the example shown above the fixed text components of temperature expansio...

Page 22: ...mple The optional character sets and the PC Tool FontManager for generating user defined character sets are included on data carrier The tool is also used to install the character sets to save charact...

Page 23: ...FN RT SX602 PFN RT 2 mod_1398435994717_48 docx 8124 2 1 Setting time date Setting of the time is done with the command SHhhmmss 38 hh stands for hours mm for minutes and ss for seconds p e SH204515 20...

Page 24: ...and keep it pressed Next setting Shortly press key Page settings forward Press key long Previous setting Double click on key Page setting backward Double click on key and keep it pressed To exit the m...

Page 25: ...95 Setting time minutes 0 59 99 Save Save parameters Set Not saving parameters Escape Restore to factory settings Default Pos 87 Si ebert Bedi enungsanlei tungen Seri e SX502 SX602 Par ametrierung Be...

Page 26: ...an be loaded with the setting It can be replaced by a user defined character set with a character height of up to 7 pixels The optional character sets and the PC tool FontManager for creating user def...

Page 27: ...FB PFN IR T PFN RT SER bis4 02 SX602 PFN RT 2 mod_1408021326172_48 docx 9307 2 1 Fault messages Serious faults due to improper operation or faulty operating conditions are indicated in the display The...

Page 28: ...U 149 213 22 _ 86 V 150 214 23 87 W 151 215 24 88 X 152 216 25 89 Y 153 217 26 EOF 90 Z 154 218 27 ESC 91 155 219 28 92 156 220 29 93 157 221 30 94 158 222 31 95 _ 159 223 32 SPACE 96 160 224 a 33 97...

Page 29: ...entry point from the bottom 0 Wall mounting cable entry point from the top 1 Hanging installation cable entry point from the bottom 2 Hanging installation cable entry point from the top 3 Wall mountin...

Page 30: ...SX602 06 25 0M 2xx xx xx ca 400 VA SX602 08 25 0R 1xx xx xx ca 180 VA SX602 08 25 0R 2xx xx xx ca 350 VA SX602 08 25 0M 1xx xx xx ca 270 VA SX602 08 25 0M 2xx xx xx ca 530 VA For units with built in h...

Page 31: ...SX602 20 05 0x 1xx xx xx representing the other unit versions listed in the following table All dimensions are in mm 70 70 a 250 70 130 45 20 20 20 20 9 Unit version a Weight SSX602 20 05 0x 1xx xx x...

Page 32: ...20 05 0x 2xx xx xx representing the other unit versions listed in the following table All dimensions are in mm 70 70 30 a 250 70 30 210 45 45 Unit version a Weight SX602 20 05 0x 2xx xx xx 1040 appro...

Page 33: ...in mm 20 20 20 20 45 130 a 70 70 70 b 9 Unit version a b Weight SX602 04 16 0x 1xx xx xx 670 300 approx 13 kg SX602 06 16 0x 1xx xx xx 960 300 approx 18 kg SX602 08 16 0x 1xx xx xx 1240 300 approx 22...

Page 34: ...are in mm 210 45 45 a 30 70 70 70 30 b Unit versions a b Weight SX602 04 16 0x 2xx xx xx 670 300 approx 22 kg SX602 06 16 0x 2xx xx xx 960 300 approx 28 kg SX602 08 16 0x 2xx xx xx 1240 300 approx 34...

Page 35: ...tion grates on units ventilated by other means The ventilation grates and their arrangement are not pictured to scale The following table specifies the ventilation grates of the individual unit versio...

Page 36: ...d by other means The ventilation grates and their arrangement are not pictured to scale The following table specifies the ventilation grates of the individual unit versions Unit version b c LG1 LG2 LG...