8.3.2
Chain of OSSD Channels
8.3.2.1
Test Setup
The test setup is made up of 4 single-axis drives and 4 double-axis drives of the device
type SD2 with the integrated safety functions SFM and SLOF.
Fig. 17: Device overview of the test setup in drivemaster2
8.3.2.2
Oscilloscope Plots
The test signals at the connector X66 / pin 10 (OSSD1) and the connector X67 / pin 10
(OSSD2) are used as OSSD signals.
Input signals at the oscilloscope:
▶
input 1 (yellow): test signal OSSD1 at X66 / pin 10
▶
input 2 (blue): signal SFM_OUT_1 at the end of the signal chain
▶
input 3 (pink): test signal OSSD2 at X67 / pin 10
▶
input 4 (green): signal SFM_OUT_2 at the end of the signal chain
OSSD Signals
W
52
Drive System SD2 - Safety Functions SFM / SLOF