background image

 13

PJC321/322

   

2921-5 - 2018


















































Panel Dimensions, PJC321

IMPORTANT! 

In case of mounting in 

rough and humid weather conditions, 

apply sealant under the panel mating 

surface to avoid water ingress. 

This template is for meas-

urements use only!

Use external template 

when mounting

Summary of Contents for PJC321

Page 1: ...ser s manual EN Made in Norway Sleipner Motor AS 2018 SLEIPNER MOTOR AS P O Box 519 N 1612 Fredrikstad Norway www side power com PJC321 PJC322 PJC321 L PJC322 L PJC321 MCL2 PJC322 MCL2 S link Control Panel SIDE POWER Thruster Systems Document id 2921 Revision 5 ...

Page 2: ...21 L PJC322 L 18 Internal wiring diagram PJC321 MCL2 PJC322 MCL2 19 SAMSVARSERKLÆRING Sleipner Motor AS P O Box 519 Arne Svendsensgt 6 8 N 1612 Fredrikstad Norway Erklærer at dette produktet med tilhørende standard kontrollsystemer er i samsvar med helse og sikkerhetskravene i henhold til DIRECTIVE 2013 53 EU DIRECTIVE 2014 30 EU DIRECTIVE 2014 35 EU DECLARATION OF CONFORMITY Sleipner Motor AS P O...

Page 3: ...tandard lever may be modified according to customer s requirements such as panel plate different scales straight or curved shafts standard Lilaas thruster control curved shafts different handles potentiometers detents and switch operation Note Separate product sheets for motorized versions of LF90 LF120 Talk to us 47 33 03 18 50 sales lilaas no More information www lilaas no has for over 35 years ...

Page 4: ...re 40 C to 70 C 40 F to 158 F Storage temperature 40 C to 85 C 40 F to 176 F IP Rating IP67 above panel EMC tested Acc to EN 13309 ISO 14982 ISO 13766 ESD tested Acc to EN 61000 4 2 ISO 7637 2 Power 9 63 Vdc 6 5 Watts EMC ESD 100V m 15kV Vibration Shock 3g 50g External Alarm Buzzer Current 0 5A Maximum Weight 250 g 0 5 lb ...

Page 5: ...HC 3 FAULT is reset by pressing the button under the loud speaker symbol The thrusters can be run when the oil alarms are active COMMUNICATION ERROR If there is a communication error between the panel and the system control unit located on the oil tank the comm error symbol will be shown on the lower left side of the panel The external buzzer can be muted by pressing the button under the loud spea...

Page 6: ...ulic system The external buzzer can be muted by pressing the button under the loudspeaker symbol SETTINGS The menu system contains of 5 settings 1 Language 2 Display Settings 3 Automatic OFF time 4 Control Setup 5 Panel Postition Select settings Exit settings Choose function AC MOTOR ALARMS HYDRAULIC AC MOTOR POWER PACK OVERTEMP The overtemp symbol will show in the upper right corner of the dis pl...

Page 7: ... seconds of inactivity 3 5 Automatic OFF time Set time from last activity to Panel automatically turns off The time can be set at 5 minutes interval ranging from 5 to 60 minutes or be disabled When Disabled is selected the panel will never be turned off automatically Settings will not affect other panels in the system Press to adjust time in 5 minutes intervals Exit setting by pressing Store setti...

Page 8: ...22 F and stop when the oil temperature goes below 40 C 104 F On systems with two oil tanks this setting will apply to both tanks 1 4 Cooling Signal Output Values Normal default Inverted Set to Normal when using a hydraulic cooling pump Should be set to Inverted when using an electrical cooling pump with a 10 2380A 12 24V relay box 1 5 Cooling Power Save Values ON default OFF ON sets the Cooling Pu...

Page 9: ...e two controllers are shown in the panel display as two different oil tanks to monitor 1 10 Thruster Valves only apply for PHC024 with FW V1 105 or higher Values Bow Stern default Bow Bow Stern Stern Thruster Valves is how the two thruster valves are set to work Bow Stern One thruster valve output runs on bow signal from con trol device and the other thruster valve output runs on stern signal from...

Page 10: ... tanks Shows oil pressure and temperature in both hydraulic tanks as well as the serial number of the panel Thrusters can be operated while this display is shown Exit Service Menu by pressing TECHNICAL SPECIFICATIONS LCD DISPLAY IP 67 Low temp functionality 40oC Mounting bracket Alarm output max load 200mA Input voltage 9 31V Max current consumption 110mA PANEL Menu System Panel mounting IMPORTANT...

Page 11: ...11 PJC321 322 2921 5 2018 Panel Dimensions ...

Page 12: ...Dimensions PJC322 This template is for meas urements use only Use external template when mounting IMPORTANT In case of mounting in rough and humid weather conditions apply sealant under the panel mating surface to avoid water ingress ...

Page 13: ...Dimensions PJC321 IMPORTANT In case of mounting in rough and humid weather conditions apply sealant under the panel mating surface to avoid water ingress This template is for meas urements use only Use external template when mounting ...

Page 14: ...formation www lilaas no LF90 Control lever Single or double operation of tunnel thruster propulsion machinery LF90 is designed for single or double operation of tunnel thruster and propulsion machinery Small robust and established as one of the most reliable maritime control levers on the market The standard lever may be modified according to customer s requirements such as panel plate different s...

Page 15: ...g other signal outputs etc Examples of standard versions of the MCL2 control lever The pictures bel differences Specifications for the non visual properties d e f are found in Longitudinal motion MCL2 SLR C L0 d e f MCL2 SLR C L1 d e f One handle Right side Fwd curved 0 100 One handle Right side Fwd curved 100 MCL2 DL C L0 d e f MCL2 DL C L1 d e f MCL2 DL C Two handles Fwd curved Both 0 100 Two ha...

Page 16: ...16 PJC321 322 2921 5 2018 S Link overview IMPORTANT Connection point must be secured as illustrated pointing upwards ...

Page 17: ...17 PJC321 322 2921 5 2018 Internal Wiring Diagram PJC321 PJC322 ...

Page 18: ...18 PJC321 322 2921 5 2018 Internal Wiring Diagram PJC321 L PJC322 L LF90S 01 37 PJC321 L LF90D 01 127 REV C PJC322 L ...

Page 19: ...AS 3 4 6 7 12 Joystick BOW Joystick STERN 1 2 violet white black red blue black brown red blue white red CAN connector Alarm buzzer output optional max 200 mA Display unit 1 6x0 75 LiYCY pink grey yellow shield Joystick Type Scana Wiring diagram PJC322 MCL2 R Holm 24 07 2012 1 1 Panel facing bow 2 3 1 2 3 YE RD GN GN RD YE TOP BOTTOM RD BU MCL2 DT S TO O 2 1 Sleipner 1 2 3 1 2 3 BOW BOW STERN STER...

Page 20: ...he time it was published However Sleipner Motor AS can not accept liability for any inaccuracies or omissions it may contain Continuous product improvement may change the product specifications without notice Therefore Sleipner Motor AS can not accept liability for any possi ble differences between product and document www side power com ...