2.2
Dimensional drawing
2
1
4
5
à ß 9
6
7
8
3
4
.8
(0
.1
9
)
28.3
(1.11)
17
(0.67)
32.8
(1.29)
9
(0
.3
5
)
1
6
(0
.6
3
)
4
4
.4
(
1
.7
5
)
3
9
.2
(
1
.5
4
)
2
.6
(0
.1
)
3
.7
(0
.1
2
)
1
.2
(0
.0
5
)
1.9
(0.07)
Ø 3.1
(0.12)
7
(0.28)
6
(0.24)
2.8
(0.11)
17.4
(0.69)
1
Receiver
2
Sender
3
Connection
4
RUN button
5
(+/Q2) button
6
Output display Q1 (orange)
7
IO-Link communication (green)
8
Output display Q2 (orange)
9
(-/Q1) button
ß
Display
à
(SET) button
3
Commissioning
3.1
Check the application conditions:
Check the application conditions: Adjust the sensing range and distance to the object
or background and the remission capability of the object according to the correspond‐
ing diagram [see H1, H2] (x = sensing range, y = minimum distance between the object
and background in mm (object remission / background remission)). Remission: 6% =
black, 90% = white (referring to standard white as per DIN 5033).
The minimum distance (= y) for background suppression can be read from diagram the
diagram [see H1
5
] as follows:
Example: x = 1,000 mm, y = 20 mm. That is, the background is suppressed at a dis‐
tance of > 20 mm from the object.
2
PRODUCT DESCRIPTION
6
8024108 | SICK
Subject to change without notice