WLL190T-2 Photoelectric switches for fibre-optic cables
2007-08-24
SENSICK
3 3
1. Selector switch to RUN
2. Operating mode Configuring
active
4. In the basic menu, select
Expert mode by pressing the
arrow keys
5. Expert mode is shown on the
display
6. Press Mode key
10. In the Analogue menu, select
definition of invalid measure-
ment values by pressing the
arrow keys
11. Definition of invalid measure-
ment values is shown on the
display
14. Finish selection with Mode key
���
���
�����������
13. Select between setting of the
output value (cLP) to 24 mA
and receipt of the last value
(hoLd) by pressing the arrow
keys
4.3 Definition of invalid measurement values
This function is only available for the analogue devices.
cLP: Sets the output value to 24 mA (factory setting),
hoLd: Retains the last value before the invalid state.
3. Press Mode key
15. Close Analogue menu with
arrow key
16. Finish selection with Mode key
7. In Expert mode, select
Analogue menu by pressing
the arrow keys
8. Analogue menu is shown on
the display
9. Finish selection with Mode key
12. Press Mode key
20. Expert mode is shown on the
display
21. Select ending the adjustment
(Exit)
22. Finish selection with Mode key
17. Analogue menu is shown on
the display
18. Close Expert mode with arrow
key
19. Finish selection with Mode key
WLL190T-2 Photoelectric switches for fibre-optic cables
34
SENSICK
2007-08-24
1. Selector switch to RUN
2. Operating mode Configuring
active
4. In the basic menu, select
Expert mode by pressing the
arrow keys
5. Expert mode is shown on the
display
6. Press Mode key
10. In the Analogue menu, se-
lect average values setting by
pressing the arrow keys
11. Average values setting is
shown on the display
15. Finish selection with Mode key
���
���
�����������
13. Select setting of the average
values by pressing the arrow
keys
4.4 Average values
This function is only available for the analogue devices.
The average is formed from a block of n values.
This value is applied to the output for the next n values, until it is
replaced by the average value of the next block of n values. This
number n can be set with the arrow keys in steps
1/4/8/16/32/64/128/256/512/1024/2048. The factory
setting is 64.
3. Press Mode key
16. Close Analogue menu with
arrow key
17. Finish selection with Mode key
7. In Expert mode, select
Analogue menu by pressing
the arrow keys
8. Analogue menu is shown on
the display
9. Finish selection with Mode key
12. Press Mode key
14. Select number of average
values by pressing the arrow
keys
21. Expert mode is shown on the
display
22. Select ending the adjustment
(Exit)
23. Finish selection with Mode key
18. Analogue menu is shown on
the display
19. Close Expert mode with arrow
key
20. Finish selection with Mode key