background image

Function Setting

Setting Amplifier Unit

Switching Channel

Pressing the 

button during the RUN mode allows switching. At the same 

time the channel indicator light switches.

Precautions for Function Setting

TOP

Select a display method of normal main sub monitor.

Select by using 

and fix by 

The screen returns to the TOP of Display 
setting.

Displayed in bar display.

Displayed in numeric display.

Displayed in percent (%) display.

Displayed in normal count display.

Displayed in total count display.

No display.

B

C

A

5.2 Display setting

TOP

Set the displayed value on the main monitor to "0."

Select by using 

and fix by 

The screen returns to the TOP of Zero reset 
setting.

Turn on Zero reset.

Turn off Zero reset.

5.1 Zero-reset setting

TOP

Select a detection method from the list below:

Select by using 

and fix by 

The screen returns to the TOP of Detection 
mode setting.

Sets to the rising edge detection.

Sets to the normal detection.

Sets to the trailing edge detection.

Sets to the differential detection.

Detects for length measurement.

5.3 Detection mode setting

TOP

Select a response speed.

Select by using 

and fix by 

The screen returns to the TOP of Response 
speed setting.

Standard setting 

500 µs

High accuracy setting  2 ms    

Fastest setting 

60 µs     

2. Response speed setting

TOP

Select an operation mode.

* The timer can be set individually for 1CH and 2CH.

Select by using 

and fix by       . The 

screen returns to the TOP of Operation setting.

ON when light is blocked.     

ON when light comes in.     

1. Operation setting

TOP

Select a timer and the time.

Timer Time Setting    1-9000 (1 ms - 9 s)

Select by using 

and fix by 

OFF moves to the TOP of Timer setting and 
others move to the Timer setting.

 

is for time changing, 

is for digit 

change, and 

is to fix. Then the screen 

returns to Timer setting TOP.

Off delay timer

Timer off

On delay timer

One shot timer

3. Timer setting

TOP

Correct to the optimal value when sensitivity is 
not enough.

Turn on using 

. The progressing status is 

displayed in bar chart.   After the end, the 
screen returns to the TOP of Sensitivity 
correction.

Turn off the sensitivity correction.

Turn on the sensitivity correction.

4. Sensitivity correction 
 setting 

TOP

Initialize all settings.

Select by using 

and fix by 

The screen returns to the TOP of 
Initialization setting.

Initialize

Not initialize

6. Initialization setting 
 (Initial 

reset)

7. End of setting

TOP

5. Detailed setting 
 (Expert 

mode)

T

Returning to Normal Display with One Button

Pressing the 

button for 2 seconds or more in setting each function enables 

to return to the normal display (RUN mode) without using Eit (Exit).

* Invalid while setting the timer time, number of count, or span slant.

Attaching and Removing to/from DIN rail

T

Press the mode button.

* The timer can be set individually for 1CH and 2CH.
* Parallel use of On delay timer and Off delay timer in 

the same channel same channel is not possible.

Number of count setting    0 - 9999999

 

is for count change,  

is for digit 

change, and 

is to fix. The screen returns 

to the Timer Setting TOP.

Slant setting

 

is for slant change,  

is for digit 

change, and 

is to fix. The screen returns 

to the TOP of Span setting.

* Settings are only for turning on (ON) or turning off 

(OFF).

Initializing changes all settings to the factory default.

A

Moves to the Detailed setting menu.

D

Moves to the analog function setting 
detail menu.

Returns to the normal display.

* Make sure to connect two amplifier units before 

differential detection.

Valid only for WSE130L-52/54.

"cnt" or "tcnt" can be select only when the counter 
function is valid.

TOP

Set the slant of output.

Select by using 

and fix by 

The screen moves to each detail setting.

Set 20 mA.

Set 4 mA.

D

5.7.2 Span setting

TOP

Select either read out or turn off the analog output.

Select by using 

and fix by 

The screen returns to the TOP of Analog 
output setting.

Reads out.

Turns off.

5.7.1 Analog output setting

TOP

Select a measurement value state when 
measurement is impossible.

Select by using 

and fix by 

.  

The screen returns to the TOP of Output 
clamp hold setting.

Hold just before measurement 
becomes impossible.

Set the output to approx. 24 mA.

5.7.3 Output clamp hold 
 setting

TOP

Select a number of times of sampling.

Select by using 

and fix by 

The screen returns to the TOP of Average 
counter setting.

Set.
Average counter

1/4/8/16/32/64/128/
256/512/1024/2048

5.7.4 Average counter setting

TOP

A single unit operates the teaching of all connected 
amplifier units. 

Select by using 

and fix by 

The screen returns to the TOP of All 
one-point teaching setting.

Performs all one point teaching.

Does not perform teaching.

B

C

5.10 All one point teaching 
 setting

TOP

Set the displayed value on the main monitor of  
connected amplifier units to 0.

Select by using 

and fix by 

The screen returns to the TOP of all zero-reset setting.

Performs all zero-reset.

Does not perform zero-reset.

5.9 All zero-reset setting

TOP

Select counter function ON/OFF and a increasing/
decreasing direction of value.

Select by using 

and fix by       .  

OFF moves to the TOP of Counter setting, 
and the others to number of count setting.

Sets the count value to the 
increasing direction.

Sets the count value to the 
decreasing direction.

Counter off

5.4 Counter setting

TOP

Select an assignment of external input.

Select by using 

and fix by 

The screen returns to the TOP of External 
input setting.

Sets to the laser off input.

Sets to the external teaching input.

Sets to the synchro input. 

(available only in use of length 
measurement function)

Sets to the counter value reset 
input.

5.6 External input setting

TOP

5.7 Analog function setting

* WI130T-P/N340 

TOP

Select a hold state.

Select by using 

and fix by 

The screen returns to the TOP of Hold setting.

Peak hold

Normal measurement

Bottom hold

Peak to Peak hold

5.7.5 Hold setting

5.7.6 End of Analog function 
 setting 

* Settable only when the length measurement function 

is in use.

TOP

Select an output method of 1CH and 2CH.

Select by using 

and fix by 

The screen returns to the TOP of Output setting.

1CH: Control output, 
2CH: Alarm output

1, 2CH: Control output

5.5 Output setting

TOP

Copy the setting to the connected amplifier units.

Select by using 

and fix by 

The screen returns to the TOP of All copy setting.

Makes copy.

Does not copy.

5.8 All copy setting

The key-locked amplifier unit setting is not 
modified.

TIP

The key-locked amplifier unit is not reset.

TIP

The key-locked amplifier unit does not 
perform teaching.

TIP

TOP

Select a width of flood line of sensor head.

Select by using 

and fix by 

The screen returns to the TOP of Length 
measurement standard value setting.

Sets to 3000.

Turns off the setting.

5.11 Length measurement 
 

standard value setting

5.12 End of Detail Setting
 (Expert 

mode)

Returns to the TOP of Detail Setting (Expert mode).

Returns to the TOP of Analog function setting.

* Full scale of the default is as follows:
Transmission, Regressive reflection, or Reflection type: 

0 - 4000 (Amount of received light)

Transmission type and in setting length measurement: 
0 - 3000 (Received light = Line width)

T

Key Lock

Cancels all the operations. Useful to prevent accidental operation.

Hold down the 

buttons for 2 seconds or more simultaneously in the 

RUN mode. Operate in the same way to cancel as well.

During key lock, no command such as all teaching/copy is accepted from other 
sensors.

TIP

In locking

When cancelled

T

T

T

After end of 4A setting, the screen moves to 20A setting.

* Some function settings automatically delete the invalid settings or settings, of 

which concomitant use is not allowed, from the displayed items. This does not 
indicate any failure.

* Some functions are not incorporated or not settable to WI130T-P/N340.
* Hold down the operation button for approx. 0.3 seconds if not especially 

specified.

* Analog output is not sent when the response speed setting is set to Fast.
   Output is available only when the setting is set to Long or Stnd (Standard).
* The sub monitor starts flashing when each setting selection becomes available.
* The monitor in use of the counter function displays "U" when the up-counter is 

selected, and displays "d" when the down-counter is selected.

* For functions other than Operation setting and Timer setting, both settings of 1 

CH and 2 CH are changed when the setting of each function is modified.

* The "all setting" described in 5.8 to 5.10 is reflected only on the amplifier unit 

connected to the right side from the cable connector of operated amplifier unit.

* WI130T-P/N340 do not allow these settings.

*  

WI130T-P/N34/33/32/12 

cannot be switched as they have a single output (1CH).

Attachment of Amplifier Unit
Hook the claw on the connecting side of 
sensor head to the DIN rail. Then press 
down the hook until it locks.

Removal of Amplifier Unit
Pushing the unit to the direction of      , 
hold up the connecting side of sensor 
head and remove the unit.

Options

BEF-BE01-W190 (2 pcs)

End Unit

 

The product specification may change without notice for improvement.

 

For any inquiry, please contact the manufacture/vendor below.

Connecting Sensor Head

Open the protective cover and plug the connector into the amplifier unit with 
the lock lever facing up.
Make sure that it clicks.
When removing, hold down the lock lever and pull out the connector.

• Do not attach any sensor head other than the specified one (W130L 

Series). 

• When removing the connector, do not pull on the cable.
  Failure to do so will break the cable or damage the product.

CAUTION

Lock Lever

Dimensional drawing

(Unit: mm)

• WI130-P/N
  340/720

Maximum aperture 180°

• WI130-P/N340