Function Setting
Setting Amplifier Unit
Switching Channel
Pressing the
button during the RUN mode allows switching. At the same
time the channel indicator light switches.
Precautions for Function Setting
TOP
Select a display method of normal main sub monitor.
Select by using
and fix by
.
The screen returns to the TOP of Display
setting.
Displayed in bar display.
Displayed in numeric display.
Displayed in percent (%) display.
Displayed in normal count display.
Displayed in total count display.
No display.
B
C
A
5.2 Display setting
TOP
Set the displayed value on the main monitor to "0."
Select by using
and fix by
.
The screen returns to the TOP of Zero reset
setting.
Turn on Zero reset.
Turn off Zero reset.
5.1 Zero-reset setting
TOP
Select a detection method from the list below:
Select by using
and fix by
.
The screen returns to the TOP of Detection
mode setting.
Sets to the rising edge detection.
Sets to the normal detection.
Sets to the trailing edge detection.
Sets to the differential detection.
Detects for length measurement.
5.3 Detection mode setting
TOP
Select a response speed.
Select by using
and fix by
.
The screen returns to the TOP of Response
speed setting.
Standard setting
500 µs
High accuracy setting 2 ms
Fastest setting
60 µs
2. Response speed setting
TOP
Select an operation mode.
* The timer can be set individually for 1CH and 2CH.
Select by using
and fix by . The
screen returns to the TOP of Operation setting.
ON when light is blocked.
ON when light comes in.
1. Operation setting
TOP
Select a timer and the time.
Timer Time Setting 1-9000 (1 ms - 9 s)
Select by using
and fix by
.
OFF moves to the TOP of Timer setting and
others move to the Timer setting.
is for time changing,
is for digit
change, and
is to fix. Then the screen
returns to Timer setting TOP.
Off delay timer
Timer off
On delay timer
One shot timer
3. Timer setting
TOP
Correct to the optimal value when sensitivity is
not enough.
Turn on using
. The progressing status is
displayed in bar chart. After the end, the
screen returns to the TOP of Sensitivity
correction.
Turn off the sensitivity correction.
Turn on the sensitivity correction.
4. Sensitivity correction
setting
TOP
Initialize all settings.
Select by using
and fix by
.
The screen returns to the TOP of
Initialization setting.
Initialize
Not initialize
6. Initialization setting
(Initial
reset)
7. End of setting
TOP
5. Detailed setting
(Expert
mode)
T
Returning to Normal Display with One Button
Pressing the
button for 2 seconds or more in setting each function enables
to return to the normal display (RUN mode) without using Eit (Exit).
* Invalid while setting the timer time, number of count, or span slant.
Attaching and Removing to/from DIN rail
T
Press the mode button.
* The timer can be set individually for 1CH and 2CH.
* Parallel use of On delay timer and Off delay timer in
the same channel same channel is not possible.
Number of count setting 0 - 9999999
is for count change,
is for digit
change, and
is to fix. The screen returns
to the Timer Setting TOP.
Slant setting
is for slant change,
is for digit
change, and
is to fix. The screen returns
to the TOP of Span setting.
* Settings are only for turning on (ON) or turning off
(OFF).
Initializing changes all settings to the factory default.
A
Moves to the Detailed setting menu.
D
Moves to the analog function setting
detail menu.
Returns to the normal display.
* Make sure to connect two amplifier units before
differential detection.
Valid only for WSE130L-52/54.
"cnt" or "tcnt" can be select only when the counter
function is valid.
TOP
Set the slant of output.
Select by using
and fix by
.
The screen moves to each detail setting.
Set 20 mA.
Set 4 mA.
D
5.7.2 Span setting
TOP
Select either read out or turn off the analog output.
Select by using
and fix by
.
The screen returns to the TOP of Analog
output setting.
Reads out.
Turns off.
5.7.1 Analog output setting
TOP
Select a measurement value state when
measurement is impossible.
Select by using
and fix by
.
The screen returns to the TOP of Output
clamp hold setting.
Hold just before measurement
becomes impossible.
Set the output to approx. 24 mA.
5.7.3 Output clamp hold
setting
TOP
Select a number of times of sampling.
Select by using
and fix by
.
The screen returns to the TOP of Average
counter setting.
Set.
Average counter
1/4/8/16/32/64/128/
256/512/1024/2048
5.7.4 Average counter setting
TOP
A single unit operates the teaching of all connected
amplifier units.
Select by using
and fix by
.
The screen returns to the TOP of All
one-point teaching setting.
Performs all one point teaching.
Does not perform teaching.
B
C
5.10 All one point teaching
setting
TOP
Set the displayed value on the main monitor of
connected amplifier units to 0.
Select by using
and fix by
.
The screen returns to the TOP of all zero-reset setting.
Performs all zero-reset.
Does not perform zero-reset.
5.9 All zero-reset setting
TOP
Select counter function ON/OFF and a increasing/
decreasing direction of value.
Select by using
and fix by .
OFF moves to the TOP of Counter setting,
and the others to number of count setting.
Sets the count value to the
increasing direction.
Sets the count value to the
decreasing direction.
Counter off
5.4 Counter setting
TOP
Select an assignment of external input.
Select by using
and fix by
.
The screen returns to the TOP of External
input setting.
Sets to the laser off input.
Sets to the external teaching input.
Sets to the synchro input.
(available only in use of length
measurement function)
Sets to the counter value reset
input.
5.6 External input setting
TOP
5.7 Analog function setting
* WI130T-P/N340
TOP
Select a hold state.
Select by using
and fix by
.
The screen returns to the TOP of Hold setting.
Peak hold
Normal measurement
Bottom hold
Peak to Peak hold
5.7.5 Hold setting
5.7.6 End of Analog function
setting
* Settable only when the length measurement function
is in use.
TOP
Select an output method of 1CH and 2CH.
Select by using
and fix by
.
The screen returns to the TOP of Output setting.
1CH: Control output,
2CH: Alarm output
1, 2CH: Control output
5.5 Output setting
TOP
Copy the setting to the connected amplifier units.
Select by using
and fix by
.
The screen returns to the TOP of All copy setting.
Makes copy.
Does not copy.
5.8 All copy setting
The key-locked amplifier unit setting is not
modified.
TIP
The key-locked amplifier unit is not reset.
TIP
The key-locked amplifier unit does not
perform teaching.
TIP
TOP
Select a width of flood line of sensor head.
Select by using
and fix by
.
The screen returns to the TOP of Length
measurement standard value setting.
Sets to 3000.
Turns off the setting.
5.11 Length measurement
standard value setting
5.12 End of Detail Setting
(Expert
mode)
Returns to the TOP of Detail Setting (Expert mode).
Returns to the TOP of Analog function setting.
* Full scale of the default is as follows:
Transmission, Regressive reflection, or Reflection type:
0 - 4000 (Amount of received light)
Transmission type and in setting length measurement:
0 - 3000 (Received light = Line width)
T
Key Lock
Cancels all the operations. Useful to prevent accidental operation.
Hold down the
buttons for 2 seconds or more simultaneously in the
RUN mode. Operate in the same way to cancel as well.
During key lock, no command such as all teaching/copy is accepted from other
sensors.
TIP
In locking
When cancelled
T
T
T
After end of 4A setting, the screen moves to 20A setting.
* Some function settings automatically delete the invalid settings or settings, of
which concomitant use is not allowed, from the displayed items. This does not
indicate any failure.
* Some functions are not incorporated or not settable to WI130T-P/N340.
* Hold down the operation button for approx. 0.3 seconds if not especially
specified.
* Analog output is not sent when the response speed setting is set to Fast.
Output is available only when the setting is set to Long or Stnd (Standard).
* The sub monitor starts flashing when each setting selection becomes available.
* The monitor in use of the counter function displays "U" when the up-counter is
selected, and displays "d" when the down-counter is selected.
* For functions other than Operation setting and Timer setting, both settings of 1
CH and 2 CH are changed when the setting of each function is modified.
* The "all setting" described in 5.8 to 5.10 is reflected only on the amplifier unit
connected to the right side from the cable connector of operated amplifier unit.
* WI130T-P/N340 do not allow these settings.
*
WI130T-P/N34/33/32/12
cannot be switched as they have a single output (1CH).
Attachment of Amplifier Unit
Hook the claw on the connecting side of
sensor head to the DIN rail. Then press
down the hook until it locks.
Removal of Amplifier Unit
Pushing the unit to the direction of ,
hold up the connecting side of sensor
head and remove the unit.
Options
BEF-BE01-W190 (2 pcs)
End Unit
The product specification may change without notice for improvement.
For any inquiry, please contact the manufacture/vendor below.
Connecting Sensor Head
Open the protective cover and plug the connector into the amplifier unit with
the lock lever facing up.
Make sure that it clicks.
When removing, hold down the lock lever and pull out the connector.
• Do not attach any sensor head other than the specified one (W130L
Series).
• When removing the connector, do not pull on the cable.
Failure to do so will break the cable or damage the product.
CAUTION
Lock Lever
Dimensional drawing
(Unit: mm)
• WI130-P/N
340/720
Maximum aperture 180°
• WI130-P/N340