This product is not an explosion-proof construction.
Do not use the product under flammable, explosive
gas or liquid environment.
Do not use the product in water.
Do not disassemble, repair, or convert the product.
Failure to do this may cause failure, fire, or electric
shock.
Operate within the rated range.
Mandatory Requirements
Each Part
Input/Output Schematic
NPN
PNP
• WI130T-N720
• WI130T-P720
• WI130T-N340
• WI130T-P340
Auto Teaching
Zone Teaching
Two Points Teaching
Teaching Transparent Object
Teaching Length Measurement
SET
RUN
Switch to SET.
SET
RUN
Switch to RUN.
Select the one point teaching.
Press the teaching button.
T
The threshold flashes and the
display returns to normal.
Transmission type (In length
measurement)
SET: Press the teaching button when
there is no object with the flood light
and the light receiver facing each
other.
IN: Press the teaching button when
there is an object.
Reflection, Transmission, Regressive
Reflection type
Start and End: Perform adjustment
while the object is passing.
Reflection type: Perform adjustment
with the background without object,
and when there is an object.
Set the zone (detection range) to ±10 %
against the amount of received light.
Set the threshold at the center
between the 1st and the 2nd points.
2nd: Perform adjustment with the
background without object.
Reflection type
1st: Perform adjustment when there
is an object.
Rotating reflection type: Perform
when there is no object.
SET
RUN
Switch to SET.
SET
RUN
Switch to RUN.
Select the auto teaching.
End: Press the teaching button.
Start: Press the teaching button.
The threshold flashes and the
display returns to normal.
*1 Operating temperature may differ according to the number of connection.
See as follows:
1 to 3 machine(s): -25 to +55°C
4 to 8 machines: -25 to +50°C * When not using analog output.
Specification
Master
Master
Model
WI130T-P/N720
W130-Series
Adaptable sensor head
12 to 24 V DC ± 10 % including a ripple
Power source, voltage
Cable type
-
-
WI130T-P/N340
M8 connector type
60μs / 500μs / 2ms (Fast/Standard/Long)
Response time
45 mA or less / 24 V
Consumption current
7-segment 8-digit display
Digital display
Timer function
OFF, On delay, Off delay, One-shot
1 ms to 9 s
Timer time
Current output:4 to 20 mA
Analog output
-25 to +55°C / 35 to 85 % RH (No freezing)
Operating temperature/humidity
*1
-40 to +70°C / 35 to 85 % RH (No condensation)
Store temperature/humidity
IP50
Protective category
10 to 55 Hz Double amplitude 1.5 mm 2 hours for each direction of X, Y, and Z
Shock resistance
Laser emission indicator light: Green, Output Indicator light: Orange (1·2CH)
Teaching indicator light: Red, Channel indicator light: Green (1·2CH)
Indicator light
Advanced Model (2CH)
Standard Model (1CH)
PC: Case and cover
Material
Cable type: 65 g, M8 connector type: 30 g
Weight (including the codes)
Control output
Load current: 100 mA or less, Residual voltage:1.8 V or less
NPN / PNP Open collector
Setting input/output
External input setting
(1 point teaching, synchronizing
input, floodlight off, counter reset)
Output
setting
(2CH Alarm output)
External input setting
(1 point teaching, synchronizing
input, floodlight off, counter reset)
Setting Maximum Sensitivity
Transmission type
Regressive Reflection type: Perform
adjustment when there is an object.
Reflection type: Perform adjustment
when there is no object.
Threshold
Threshold
Upper limit
Lower limit
10%
10%
Zo
n
e
Near
Far
Valid only when the length measurement function is set. Allows to
determine the size or the length of object.
* Not displayed on the teaching mode menu unless the application of length
measurement is selected in the detection mode setting.
* Teaching length measurement or length measurement mode does not measure
the actual length of object accurately.
Manual Adjustment
Pressing the UP/DOWN button in the RUN mode flashes the threshold.
It indicates that adjustment is possible. Adjust to any value using the
UP/DOWN button.
When using the zone teaching, the threshold of upper/lower limit can
be set individually.
Error Display in Teaching
An error message is displayed in the event of error during adjustment.
Refer to the table below for readjustment.
* No operation state for 5 seconds during setting automatically returns the display
to normal as well.
SET
RUN
Switch to SET.
SET
RUN
Switch to RUN.
Select the two points teaching.
2nd point: Press the teaching button.
T
1st point: Press the teaching button.
T
T
T
The threshold flashes and the
display returns to normal.
SET
RUN
Switch to SET.
SET
RUN
Switch to RUN.
IN: Press the teaching button.
SET: Press the teaching button.
T
T
The upper limit flashes and
the display returns to normal.
SET
RUN
Switch to SET.
SET
RUN
Switch to RUN.
Press the teaching button.
T
The threshold flashes and the
display returns to normal.
SET
RUN
Switch to SET.
SET
RUN
Switch to RUN.
Select the zone teaching.
Press the teaching button.
T
The threshold flashes and the
display returns to normal.
Normal
Automatically returns to
the normal display 5
seconds after completion of
the setting (no operation).
When using zone teaching
Setting Lower Limit (Far)
Automatically returns to the normal display
5 seconds after completion of the setting
(no operation).
Indicates shortage of light intensity or no
difference of light intensity.
Indicates a sampling error in teaching of a moving object.
Indicates a calculation error.
Indicates that the teaching is interrupted.
Setting Upper Limit (Near)
WARNING
Operational Precautions
CAUTION
Use the specified sensor head to connect this
product. Any use other than specified will cause
accident or product damage.
It is dangerous to wire or attach/remove the
connector with the power on. Make sure to turn
off the power before operation.
Make sure to use the product with the
protective cover attached and closed.
Installing in the following places may result in
malfunction:
1. A dusty or steamy place
2. A place generating corrosive gas
3. A place directly receiving scattering water
or oil.
4. A place suffered from heavy vibration or
impact.
The product is not designed for outdoor use.
Do not use the sensor in transient state after
power on (approx. 100 ms).
Do not wire with the high voltage cable or the
power line. Failure to do this will cause
malfunction by induction or damage.
The sensor performance or digital display values
may depend on the individual units or the condition
of detected product.
Name
No.
Function
Laser emission indicator light Turns on while the amplifier is powered.
1 CH output indicator light Turns on when the output of 1 CH is ON.
2 CH output indicator light Turns on when the output of 2 CH is ON.
Main monitor (Red)
Displays light intensity, function, and the number of counts.
Sub monitor (Green)
Displays the threshold, function selection, and the number of counts.
Teaching mode indicator light Turns on in the Teaching mode.
Valid channel indicator light
(1 CH)
Keeps turning ON when the monitor display value,
adjustment, and the function setting are valid to 1 CH.
Valid channel indicator light
(2 CH)
Keeps turning ON when the monitor display value,
adjustment, and the function setting are valid to 2 CH.
UP button
RUN mode: Displays or changes the threshold.
DOWN button
Function mode: Selects the function or changes the numerical values.
Mode button
RUN mode: Switches to the Function mode. (0.5 s ≥)
Function mode: Fix the selection.
Teaching button
RUN mode: Switches the channel.
Function mode: Returns to RUN mode or performs scaling.
Set mode: Run the teaching.
SET/RUN selection switch Switches between Teaching mode and RUN mode.
* The button function varies in each mode: RUN mode, Function mode, and SET mode.
* WI130T-P/N340 are 1 output (1 CH) type, and do not turn on.The channel
switching of also becomes invalid.
Main cir
c
uit
Protective
circuit
Protective
circuit
Load
Load
Black and
white
Gray
Blue
White
Black
Brown
Analog output
0 V
Analog GND
External input
Control output 1 CH
12 to 24 V DC
Control output 2 CH
Main cir
c
uit
Protective
circuit
Protective
circuit
Load
Load
Black and
white
Gray
Blue
White
Black
Brown
Analog output
0 V
Analog GND
External input
Control output 1 CH
12 to 24 V DC
Control output 2 CH
Main cir
c
uit
Protective
circuit
Lo
ad
Gray
Blue
Black
Brown
12 to 24 V DC
Control output 1 CH
External input
0 V
1
4
2
3
Main cir
c
uit
Protective
circuit
Load
12 to 24 V DC
Control output 1 CH
External input
0 V
Gray
Blue
Black
Brown
1
4
2
3
2nd
1st
Threshold
Set the threshold to -10 % against the
amount of received light.
-10%
Threshold
Reflection side
of reflector
Amplifier Unit WI130
We reserve the right to make changes without prior notification
04 06
Adjustment
The available teaching depends on "5.3 Detection Mode setting." Refer to below:
/
(Standard detection)
All teachings are valid.
(Edge detection)
No teaching is valid.
(Differential detection)
Only one point teaching is valid.
Australia
Phone +61 3 9497 4100
E-Mail: [email protected]
Belgium/Luxembourg
Phone +32 (0)2 466 55 66
E-Mail: [email protected]
Brasil
Phone +55 11 5091-4900
E-Mail: [email protected]
Ceská Republika
Phone +420 2 57 91 18 50
E-Mail: [email protected]
China
Phone +852-2763 6966
E-Mail: [email protected]
Danmark
Phone +45 45 82 64 00
E-Mail: [email protected]
Deutschland
Phone +49 (0)2 11 53 01-0
E-Mail: [email protected]
España
Phone +34 93 480 31 00
E-Mail: [email protected]
France
Phone +33 1 64 62 35 00
E-Mail: [email protected]
Great Britain
Phone +44 (0)1727 831121
E-Mail: [email protected]
India
Phone +91 –22– 2822 7084
E-Mail: [email protected]
Italia
Phone +39 02 27 40 93 19
E-Mail: [email protected]
Japan
Phone +81 (0)3 3358 1341
E-Mail: [email protected]
Nederlands
Phone +31 (0)30 229 25 44
E-Mail: [email protected]
Norge
Phone +47 67 81 50 00
E-Mail: [email protected]
Österreich
Phone +43 (0)22 36 62 28 8-0
E-Mail: [email protected]
Polska
Phone +48 22 837 40 50
E-Mail: [email protected]
Republic of Korea
Phone +82-2 786 6321/4
E-Mail: [email protected]
Republika Slowenija
Phone +386 (0)1-47 69 990
E-Mail: [email protected]
Russia
Phone +7 95 775 05 30
E-Mail [email protected]
Schweiz
Phone +41 41 619 29 39
E-Mail: [email protected]
Singapore
Phone +65 6744 3732
E-Mail: [email protected]
Suomi
Phone +358-9-25 15 800
E-Mail: [email protected]
Sverige
Phone +46 8 680 64 50
E-Mail: [email protected]
Taiwan
Phone +886 2 2365-6292
E-Mail: [email protected]
Türkiye
Phone +90 216 388 95 90 pbx
E-Mail: [email protected]
USA/Canada/México
Phone +1(952) 941-6780
E-Mail: [email protected]
More representatives and agencies
in all major industrial nations at
www.sick.com
2t
ni
Z
B
0
06
·
e
et
n
ar
a
u
g
y
n
a
t
n
e
s
er
p
er
t
o
n
o
d
at
a
d l
a
ci
n
h
c
et
d
n
a
s
er
ut
a
ef
t
c
u
d
or
p
d
eif
i
c
e
p
s
e
h
T
Safety Precautions
Carefully read and understand the safety precautions before operation.
The important information is provided to protect your health and property.
Do not apply any other installing or operating procedure other than that described
in this manual.
Meanings of Safety Symbols
Indicates a possible hazard that may result in death,
serious injury, or serious property damage if the pro-
duct is used without observing the stated instructions.
WARNING
Indicates a possible hazard that may result in
personal injury or property damage if the product is
used without observing the stated instructions.
CAUTION
For further information regarding the configuration menu and
teaching function please take note of the handbook. Available on
the internet at www.sick.com or from your contact person at SICK.
This product cannot be used as a safety device to
protect human body.
Use of controls or adjustments or performance of
procedures other than those specified herein may
result in hazardous radiation exposure.
CAUTION
Pin layout
WI130T-P/N340
1
2
4
3
External input
12 to 24 V DC
Control output
0 V
SET
RUN
Switch to SET.
SET
RUN
Switch to RUN.
Select the one point teaching.
Press the teaching button.
T
The threshold flashes and the
display returns to normal.
One Point Teaching
Reflection type: Perform adjustment
with the background without object.
Set the threshold against the amount of
received light.
(Depends on the response speed setting.)
Long +1%
Stnd +5%
FaSt +15%
Threshold