14
SICK WSU 26/2 – WEU 26/2
8 008 692/9-12-99 Technical Description · WSU/WEU 26-2 © SICK AG · Safety Systems · Germany · All rights reserved
7.2 Wiring Diagram
Fig. 14: Wiring diagram WSU/WEU for AC supply, with PG connector
Fig. 13: Wiring diagram WSU/WEU for 24 V DC supply, with PG connector
1/2
3
4
5
6
7
8
9
PE +24V
1/2
3
10
11
PE +24V
0V
0V
1/2
3
4
5
6
7
8
9
PE
1/2
3
10
11
PE
230V/
115 V
N
N
230V/
115 V
Connecting leads
max. 1.5 mm
2
WSU
Test contact (10, 11)
Floating
U 24 V DC
I
10 mA
Opening time
t
≥
50 ms
WEU
Outputs (4 - 9)
Umax.
250 V AC
Imax.
2 A per output
Imin.
0.02 A per output