3
Yellow LED: status of received light beam
4
Green LED: supply voltage active
4
Mounting
Mount the sensor and the reflector using suitable mounting brackets (see the SICK
range of accessories). Align the sensor and reflector with each other.
Note the sensor’s maximum permissible tightening torque of < 0,4 Nm.
5
Electrical installation
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
–
Male connector connection: Pin assignment
–
Cable: Wire color
Only apply voltage/switch on the voltage supply once all electrical connections have
been established.
Explanations on connection diagram.
BN = brown
WH = white
BU = blue
BK = black
Test = Test input
U
B
: 10 ... 30 V DC
Table 8: Electrical connection
WLF4Fx-
x4
x2
xH
x1
-xG
1 = BN
2 = WH
3 = BU
4 = BK
1
2
4
3
4
3
2
1
0.14 mm
2
AWG26
4
3
1
0.14 mm
2
AWG26
Table 9: DC
WLF4Fx-
xx112xA0Zxx
xx111xA0Zxx
1 = BN
+ (L+)
2 = WH
Q
Q
3 = BU
- (M)
4 = BK
Q
Q
Table 10: DC
WLF4Fx-
xx312xA0Zxx
xx311xA0Zxx
1 = BN
+ (L+)
3 = BU
- (M)
4 = BK
Q
Q
MOUNTING
4
8027380.1DTW /2022-02-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | WLF4F
17
Subject to change without notice
en
Summary of Contents for W4F
Page 46: ...WLF4F de en es fr it ja ko pl pt ru zh...
Page 68: ...WLF4F de en es fr it ja ko pl pt ru zh...
Page 78: ...11 11 1 www sick com P N Ident no 11 78 WLF4F 8027380 1DTW 2022 02 14 SICK ko...
Page 101: ...WLF4F de en es fr it ja ko pl pt ru zh...