Technical data
Table 10: Technical data
WT34-
Bx4x / -
Bx5x / -
Vx4x / -Vx5x
-Rx4x / -
Rx5x
-Bx1x / -
Vx1x / -
Bx2x / -Vx2x
-Rx1x / -
Rx2x
Sensing range
100 ... 1200
mm
100 ... 1200
mm
100 ... 2500
mm
100 ... 2500
mm
Sensing range max.
100 ... 1200
mm
1)
100 ... 1200
mm
1)
100 ... 2500
mm
1)
100 ... 2500
mm
1)
Light spot diameter/distance
Ø 40 mm
(1.200 mm)
Ø 40 mm
(1.200 mm)
Ø 80 mm
(2.500 mm)
Ø 80 mm
(2.500 mm)
Supply voltage U
B
DC 10 ... 30
V
AC / DC
20 ... 250
V
2)
DC 10 ... 30
V
AC / DC
20 ... 250
V
2)
Output current I
max.
100 mA
100 mA
Switching current (switching voltage)
I
max.
4 A@250 V
AC,
4 A@24 V
DC,
0.125 A@25
0 V DC
3)
4 A@250 V
AC,
4 A@24 V
DC,
0.125 A@25
0 V DC
3)
Switching frequency
1000 Hz
4)
10 Hz
4)
1000 Hz
4)
10 Hz
4)
Max. response time
≤ 500 µs
5)
≤ 10 ms
5)
≤ 500 µs
5)
≤ 10 ms
5)
Enclosure rating
6)
-B2x0, -
B3x3, -V2x0:
IP67
-B4x0, -
V5x0: IP69
7)
-R2x0: IP67
-B2x0, -
B3x3, -V2x0:
IP67
-B4x0, -
V5x0: IP69
7)
-R2x0: IP67
Protection class
II
8)
II
8)
II
8)
II
8)
Circuit protection
A, B, C
9)
A, C
9)
A, B, C
9)
A, C
9)
Ambient operating temperature
–40 °C ...
+60 °C
–40 °C ...
+60 °C
–40 °C ...
+60 °C
–40 °C ...
+60 °C
1)
Object with 90 % remission (based on standard white DIN 5033)
2)
Limit values; terminal connection: permissible wire cross-sections 0.14 to 1.5 mm
2
, male connector:
≤ 4 A
3)
Usage category: AC-15, DC-13 (EN 60947-1)
4)
With light / dark ratio 1:1
5)
Signal transit time with resistive load
6)
Pursuant to EN 60529
7)
Replaces IP69 K pursuant to ISO 20653: 2013-03
8)
Rated insulation voltage U
i
250 V, overvoltage category II
9)
A = U
B
-Anschlüsse verpolsicher
B = Ein- und Ausgänge verpolsicher
C = Störimpulsunterdrückung