7.2.2
Removing device
NOTE!
DO NOT VIOLATE LFT MODE
Controllers in legal-for-trade systems are provided with a seal.
If the controller is replaced by the customer in the event of a repair, the system will
be operational again but must no longer be used for billing purposes.
In this case, contact the responsible weights and measures authority after replacing
the component so that the system can be made legal-for-trade compliant again and
used for billing purposes.
The SIM2000-2 Prime controller is mounted on the wall of the cabinet using two mounting
plates belonging to the side housing, each with two socket head screws.
Fig. 38: Removing the MSC800
▸
Undo and remove the socket head screws.
▸
Take the controller out of the cabinet.
Fig. 39: Removing the microSD card from the MSC800
▸
Remove the microSD card from the card slot on the side in the removed controller.
▸
Insert the removed microSD card into the corresponding card slot on the new
controller.
Removing a
defective device
Transferring the
microSD card