Addendum Operating Instructions
Chapter
5
S3000 PROFINET IO/IO OF
8013291/YY95/2016-02-05
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
13
Subject to change without notice
Electrical installation
5.1.2
Network connection with RJ 45-push-pull plug
For the connection to the network you must use the push-pull plugs with a metal hous-
ing. With the push-pull plug connected the connection complies with enclosure rating
IP 65 (e.g. Phoenix VS
8
PPC
8
C1
8
RJ45-MNNA-PG9-4Q5, material no. 1608100).
With the provided cover the connection complies with enclosure rating IP 54.
If the network is not connected to a following bus device, then a connection using a plug
is sufficient. It does not matter which of the two sockets is used. The unused socket
must always be protected with the provided cover (see Fig. 1).
Pin
Signal
PROFINET IO colours
1
TX+ Yellow
2
TX– Orange
3
RX+ White
4
–
Do not use
5
–
Do not use
6
RX– Blue
7
–
Do not use
8
–
Do not use
Notes
Fig. 5: RJ
45-push-pull plug
(not included)
Tab. 4: Pin assignment on
the RJ
45 sockets