S300 Standard
Safety laser scanner
7024240
Connection diagrams
➜
You can find connection diagrams at www.sickusa.com/connectiondiagrams
With restart interlock and external device monitoring
2)
■
S300 Standard in conjunction with relays/contactors
■
Operating mode: with restart interlock and external device
monitoring (EDM)
Comments
1) Output circuits: These contacts are to be connected to the
controller such that, with the output circuit open, the dange-
rous state is disabled. For categories 4 and 3, the integration
must be dual-channel (x/y paths). Single-channel integration
in the control (z path) is only possible with a single-channel
control and taking the risk analysis into account.
2) Functional earth (FE): To achieve the specified EMC safety,
the functional earth (FE) must be connected (e.g. to the cen-
tral earth star point on the vehicle or the system).