 SICK, Inc., USA. All rights, including changes to technical specifications 

and or to the equipment without prior notification, are reserved.

C - 61

S300 Standard 

Safety laser scanner

7024240

Connection diagrams

➜ 

You can find connection diagrams at www.sickusa.com/connectiondiagrams

With restart interlock and external device monitoring

2)

■ 

S300 Standard in conjunction with relays/contactors

■ 

Operating mode: with restart interlock and external device 

monitoring (EDM)

Comments

1) Output circuits: These contacts are to be connected to the 

controller such that, with the output circuit open, the dange-

rous state is disabled. For categories 4 and 3, the integration 

must be dual-channel (x/y paths). Single-channel integration 

in the control (z path) is only possible with a single-channel 

control and taking the risk analysis into account.

2) Functional earth (FE): To achieve the specified EMC safety, 

the functional earth (FE) must be connected (e.g. to the cen-

tral earth star point on the vehicle or the system).

Summary of Contents for S300 Standard

Page 1: ...pe 3 IEC EN 61496 3 Safety integrity level SIL2 IEC EN 61508 Product description High end safety at entry level price The low cost solution for simple require ments with one protective field and war n...

Page 2: ...IEC EN 61496 3 Safety integrity level SIL2 IEC EN 61508 Ambient operating temperature from to 10 C 50 C Type of light Pulsed laser diode Wave length 905 nm Housing colour RAL 1021 Housing material Alu...

Page 3: ...oltage Vs 24 V DC 16 8 V DC 30 V DC Power consumption 0 33 A 24 V DC Power consumption 1 65 A 1 Number of inputs EDM Restart Reset Standby 1 1 1 Number of safety capable outputs Safety outputs OSSD Ou...

Page 4: ...ing changes to technical specifications and or to the equipment without prior notification are reserved C 60 S300 Standard Safety laser scanner 7024240 Scan plane origin 73 130 146 270 23 8 116 36 4 7...

Page 5: ...ntactors Operating mode with restart interlock and external device monitoring EDM Comments 1 Output circuits These contacts are to be connected to the controller such that with the output circuit open...

Page 6: ...can be easily identified via the comprehensive diagnostics functions That significantly reduces machine down times SICK offers solutions for the open automation standards AS i Safety at Work DeviceNe...

Page 7: ...necting the configuration connection to the PC M8 x 4 SUB D 9 pol 2 m 6021195 8 m 2027649 Configuration software Type Description Part number CDS CDS Configuration Diagnostic Software on CD ROM includ...

Page 8: ...hanges to technical specifications and or to the equipment without prior notification are reserved C 64 S300 Standard Safety laser scanner 7024240 Mounting kit 2 31 7 33 4 18 19 7 19 7 18 4 78 2 40 7...