Operating instructions Register sensors RS25
Structure and function
Function indicators (LEDs)
Function indicator
Description
Power
Supply voltage available.
• Green LED:
Normal operation/Supply voltage on
• LED off: No operation
MF
Without function
S/E
Ethernet Powerlink connection display
• Green LED: Ethernet Powerlink connection correctly
connected
• Red LED: Faulty Ethernet Powerlink connection
Eth/Link (x 2)
Ethernet connection display
• Green LED: Ethernet connection available
• LED off: No Ethernet connection available
Eth/Act (x 2)
Data transfer display
• Green LED: Data transfer
• LED off: No data transfer
Table 2:
Function indicators (LEDs)
Symbols for modes
The register sensor distinguishes between the modes "Operation", "Com-
missioning" and "Parameterization and Diagnosis".
Symbol
Description
RUN
The RUN symbol is displayed in operating mode.
SET
The SET symbol is displayed in commissioning mode.
Commissioning comprises the following steps:
• Check reflection quality/contrast quality.
• Teach-in background
• Teach-in key code
• Teach-in print marks
MEN
The MEN symbol is displayed in configuration and diagnos-
tic modes.
Table 3:
Symbols for modes
Pushbuttons
Pushbutton
Description
• Select menu, parameter, or option.
• Reduce value.
• Select menu, parameter, or option.
• Increase value.
SET
• Switch to the "Menu" level.
• Switch to the next-lowest menu level.
• Save parameter change.
• Confirm selection.
ESC
• Short press: Exit parameters without saving. Switch to
the next-highest menu level.
• Long press: Exit parameters without saving. Switch to
the bar graph display.
Table 4:
Pushbuttons