background image

The 4 threaded mounting holes on the left and right side of the housing are

used to mount the device on a bracket. Only use screws with M5 thread.

Insert the screws into the thread by a maximum of 9 mm.

Use of a weather hood and a mounting bracket is recommended for

outdoor installations. Information about optional accessories

Accessories,

page 2

.

Do not mount device tilted toward the ground in order to prevent ground

reflections, which could be detected as objects.

No detection is possible within the blind zone. The blind zone is specified in

the technical data.

5

Electrical installation

5.1 Wiring instructions

NOTE

Pre-assembled cables can be found online at:

www.sick.com/RMS1000

NOTICE

Faults during operation and device or system defects!

Incorrect wiring may result in operational faults and defects.

Follow the wiring notes precisely.

The enclosure rating stated in the technical data is achieved only with screwed

plug connectors or protective caps.
Isolate the wires of unused digital outputs at the control cabinet.
All circuits connected to the device must be designed as ES1 circuits. The voltage

source must meet the requirements of ES1 and PS2 (EN 62368-1).
Connect the connecting cables in a de-energized state. Do not switch on the sup‐

ply voltage until installation is complete and all connecting cables are connected

to the device and control.
Use suitable connecting cables and connectors for the application and ambient

conditions

see Accessories, page 2

.

The supply voltage must be as specified in the technical data.
The voltage supply via a power supply unit must be capable of buffering a brief

power failure of up to 20 ms.
Prevent product damage caused by short-circuit: The device supply voltage input

is equipped with reverse polarity protection. The internal functional earth is

directly connected to the metal housing of the device. The internal functional

earth also corresponds to the negative pole of the supply voltage.

5.2 Connection diagram
Ethernet

Pin assignment for Ethernet connection

Male/female

connector

Pin

Short form

Signal description

M12 female

connector, 4-pin

D-coded

1

4

3

2

1

TX+

Transmit data positive

2

RX+

Receive data positive

3

TX-

Transmit data negative

4

RX-

Receive data negative

CAN I/O

Pin assignment for CAN I/O connection

Male/female

connector

Pin

Short form

Signal description

M12 male con‐

nector, 8-pin A-

coded

1

7

2

6

3

4

5

8

1

CAN H

CAN high

2

CAN L

CAN low

3

IN2

Input 2

4

GND IN1/2 Earth input 1/2

5

OUT2

Output 2

6

OUT3

Output 3

7

GND

Earth

8

OUT4

Output 4

Power

Pin assignment Power connection

Male/female

connector

Pin

Short form

Signal description

M12 male con‐

nector, 5-pin A-

coded

1

4

3

5

2

1

L+

Supply voltage: +9 V DC … +32 V DC

2

IN1

Input 1

3

GND

Earth

4

OUT1

Output 1

5

GND IN1/2 Earth input 1/2

5.3 Connecting the device electrically

1.

Ensure the voltage supply is not connected.

2.

Connect the device according to the connection diagram, 

Connection dia‐

gram, page 2

.

3.

Switch on the supply voltage.

6

Operation

6.1 General advice

The device works fully automatically in normal operation and requires no operator

intervention.

6.2 Switching off and on

1.

To switch off the device, disconnect the device from the voltage supply.

The device switches off. The device configuration remains unchanged, meas‐

ured values are lost.

2.

Connect the device to the voltage supply.

The device starts with the last saved configuration data.

6.3 Configuration

Parameterize the device using the SOPASair configuration software.
Opening user interface:
1.

Start web browser (recommendation: Google Chrome).

2.

Enter the device IP address into the address line. The following IP address is

pre-configured by default: 192.168.0.1.

The SOPASair user interface appears.

7

Technical data (excerpt)

NOTE

The relevant online data sheet for your product, including technical data,

dimensional drawing, and connection diagrams, can be downloaded, saved,

and printed from the Internet:

www.sick.com/RMS1000

7.1 Features

Measurement principle

FMCW

Radio equipment appro‐

val

For country-specific restrictions see “Regulatory Compliance

Information” (no. 8021596) technical information (downloads),

also included with the product

Frequency band

RMS-A (ETSI): 61 GHz … 61.5 GHz

RMS-C (Japan): 60.5 GHz … 61 GHz

RMS-E (FCC): 61 GHz … 61.5 GHz

Transmitting power

< 20 dBm (e.i.r.p.)

Aperture angle

Horizontal: ± 60°

Vertical: ± 4°

Working range

0.4 m … 100 m

Blind zone

0.00 m ... 0.4 m

Detection capability

At 1 m² RCS 

1

: 50 m

At 10 m² RCS 

2

: 100 m

Distance accuracy

1 m² RCS 

1

 to 20 m: 0.04 m

1 m² RCS 

2

 to 50 m: 0.1 m

Distance resolution

0.4 m

Speed Range

-30 m/s … +30 m/s

Speed resolution

0.625 m/s

Speed accuracy

1 m² to 20 m: 0.0625 m/s

1 m² to 50 m: 0.15 m/s

1

Typical radar cross section value for a pedestrian.

2

Typical radar cross section value for a car.

Working ranges based on distance

Distance [m]

1

5

10

20

40

60

80

100

Vertical

0.1

0.7

1.4

2.8

5.6

8.4

11.2

14.0

Horizontal

3.5

17.3

34.6

69.3

138.6

207.8

277.1

346.4

7.2 Mechanics/electronics
Dimensional drawing

Dimensional drawing RMS1000: 

A

8

Accessories

NOTE

Accessories and, if applicable, mounting information can be found online at:

www.sick.com/RMS1000

8026121/1F9Q/2022-06-20/en, de, es, pt, ko

RMS1000 (RMS-A, RMS-C, RMS-E) | SICK

2

Summary of Contents for RMS-A

Page 1: ...integrated into the device access via web browser 1 Protective caps for electrical connections Included or possibly attached to the device 1 Printed RMS1000 Regulatory Notes technical information no...

Page 2: ...6 OUT3 Output 3 7 GND Earth 8 OUT4 Output 4 Power Pin assignment Power connection Male female connector Pin Short form Signal description M12 male con nector 5 pin A coded 1 4 3 5 2 1 L Supply voltag...

Page 3: ...ende Komponenten St ck Komponente Bemerkung 1 Ger t in der bestellten Ausf h rung Ohne Anschlussleitungen und Halterungen 1 Konfigurationssoftware SOPASair Im Ger t integriert Zugriff ber Webbrowser 1...

Page 4: ...1 2 Erde Eingang 1 2 5 OUT2 Ausgang 2 6 OUT3 Ausgang 3 7 GND Erde 8 OUT4 Ausgang 4 Power Pinbelegung Anschluss Power Stecker Dose Kontakt Kurzzeichen Signalbeschreibung M12 Stecker 5pol A Kodiert 1 4...

Page 5: ...bles de conexi n 1 Software de configuraci n SOPASair Integrado en el equipo acceso mediante navega dor web 1 Tapas protectoras para cone xiones el ctricas Adjunto o si conviene instalado 1 Informaci...

Page 6: ...Contacto Abreviaci n Descripci n de se al Conector macho M12 8pol Con codificaci n A 1 7 2 6 3 4 5 8 1 CAN H Can high 2 CAN L CAN low 3 IN2 Entrada 2 4 GND IN1 2 Entrada tierra 1 2 5 OUT2 Salida 2 6 O...

Page 7: ...va o 1 Dispositivo no modelo enco mendado Sem cabos de conex o e suportes 1 Software de configura o SOPASair Integrado no dispositivo acesso com browser da web 1 Tamp es cegos para conex es el tricas...

Page 8: ...o A 1 7 2 6 3 4 5 8 1 CAN H CAN high 2 CAN L CAN low 3 IN2 Entrada 2 4 GND IN1 2 Entrada terra 1 2 5 OUT2 Sa da 2 6 OUT3 Sa da 3 7 GND Terra 8 OUT4 Sa da 4 Power Ocupa o de pinos conex o Power Conecto...

Page 9: ...elegram Listing SICK www sick com RMS1000 All rights reserved 2 2 1 RMS1000 Ethernet CAN J1939 SICK AG SOPASair RMS1000 No 8026123 SICK AG 3 3 1 1 1 SOPASair 1 1 RMS1000 No 8026123 www sick com 802612...

Page 10: ...oogle Chrome 2 IP IP 192 168 0 1 SOPASair 7 www sick com RMS1000 7 1 FMCW Regulatory Compliance Information No 8021596 RMS A ETSI 61GHz 61 5GHz RMS C 60 5GHz 61GHz RMS E FCC 61GHz 61 5GHz 20dBm e i r...

Page 11: ...A 8026121 1F9Q 2022 06 20 en de es pt ko RMS1000 RMS A RMS C RMS E SICK 11...

Reviews: