Technical Information
Chapter
4
RFU63x
Electrical installation
8014335/YUO7/2016-04-04
©
SICK AG · Germany · All rights reserved · Subject to change without notice
61
4.8.12
Wiring the "Result 2" switching output in the CDB650-204 connection module
RFU630
CDB650-204
U
IN
* = DC 18 V ... 30 V
Load (e.g. PLC)
Cable
1)
, e.g.
no. 6052286 (2 m)
14
1
.
.
.
22
GND
5
Shield
U
IN
*
V
S
GND
V
out
Result 2
GND
14
1
2
2
Ratings for “Result 2” switching output
21
Res/Out 2
Quenching circuit:
Install an
anti-surge diode
directly at the
load!
For inductive load:
1) Cable:
No. 6052286 (2 m)
No. 6051194 (3 m)
No. 6051195 (5 m)
PNP switching against the supply voltage V
S
(default setting: no function,
logic: not inverted [active high])
– Short-circuit proof + temperature protected
– Galvanically not separate from V
S
0 V ≤ V
out
≤ V
S
(V
S
− 1.5 V) ≤ V
out
≤ V
S
with I
out
≤ 100 mA
Switching
behavior
Features
Electrical
values
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
M12, 17-pin, A-coded
Female
connector
Male
connector