background image

SICK AG hereby declares that the RFU610-106xx radio equipment complies with

the 2014/53/EU directive. The complete text of the EU declaration of conformity

is available at the following web address

www.sick.com/RFU61x

.

12 Device overview

RFU610-106xx: Device overview

Regional

assign‐

ment

Firmwa

re from

version

Carrier fre‐

quency

Transmitting

power of the

internal

antenna

Device

type

Part no.

Supplied

Quickstart

(Part no.)

Europe

V2.06

865.7 MHz ...

867.5 MHz

Max. 24 mW

(ERP

 

1)

)

RFU610-

10600

1091102 English

(8023832),

German

(8024099)

USA/

Canada

V2.06

902.75 MHz ...

927.25 MHz

Max. 42 mW

(EIRP

 

2)

)

RFU610-

10601

1099890 English

(8023832)

1)

ERP = equivalent radiated power.

2)

EIRP = equivalent isotropic radiated power.

12.1 Operational restrictions

NOTICE

Operational restrictions!

When delivered, the frequency band of the RFU610-106xx is configured in

such a way that it can be operated in the following assigned regions (depend‐

ing on the model) without interfering with protected frequencies (such as

mobile communications):

RFU610-10600 (Europe)

RFU610-10601 (USA/Canada)

Operating the same RFU610-106xx in other regions can interfere with pro‐

tected frequencies.

Only use the RFU610-106xx in the region for which it has been

approved.

When reselling the RFU610-106xx, inform the buyer of the regional

assignment.

France

The RFU610-106xx must not be operated within a 20 km radius of 13 military

zones.

Lithuania

There may be restrictions in Lithuania (extent not currently known).

USA

(1) This device complies with part 15 of the FCC Rules. Operation is subject to the

following two conditions:
(1) This device may not cause harmful interference, and (2) this device must

accept any interference received, including interference that may cause undesired

operation.
(2) Changes or modifications not expressly approved by the party responsible for

compliance could void the user’s authority to operate the equipment.
(3) Note: This equipment has been tested and found to comply with the limits for

a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are

designed to provide reasonable protection against harmful interference when the

equipment is operated in a commercial environment. This equipment generates,

uses, and can radiate radio frequency energy and, if not installed and used in

accordance with the instruction manual, may cause harmful interference to radio

communications. Operation of this equipment in a residential area is likely to

cause harmful interference in which case the user will be required to correct the

interference at his own expense.
(4) To comply with FCC part 15 rules in the United States, the system must be pro‐

fessionally installed to ensure compliance with the Part 15 certification.
(5) It is the responsibility of the operator and profes-sional installer to ensure that

only certified systems are deployed in the United States. The use of the system in

any other combination (such as co-located antennas transmitting the same infor‐

mation) is expressly forbidden.
(6) This device complies with the limit values defined by the FCC for radio radia‐

tion in an uncontrolled environment. The device must have a minimum distance

of 20 cm between the source of radiation and your body.

Canada

(1) This Class A digital apparatus complies with Canadian ICES-003.
(2) This device satisfies the Industry Canada CNR applicable to license-free radio

equipment. Use is permitted providing the two following conditions are met: (1)

The device must not cause any faults and (2) the user of the device must accept

any fault produced in the device, even if this may impair its function.

13 Sources for obtaining more information

Additional information about the device, its optional accessories, and fieldbus

modules can be found in electronic format on the following product pages on the

Internet at:

13.1 RFU610-106xx read/write device

www.sick.com/RFU61x

Summary of type-specific technical data (online data sheet)

EU declaration of conformity

Dimensional drawing and 3D CAD dimension models in various electronic

formats

Suitable accessories (includingu. a. transponders, cables, brackets, trigger

sensors)

Quickstart RFU610-106xx read/write device (UHF) in English (no. 8023832)

and German (no. 8024099)as well as in other languages

Ordering information, e.g. in the RFID Product Information in English

(no. 8016267) and German (no. 8016266)

Publications dealing with accessories

13.2 Function blocks

www.sick.com/RFU61x

Function blocks for communication between a SIMATIC controller (S7-300/

S7-400) and the device.

Function blocks for other controllers on request.

13.3 Documents on request

Overview of command strings of the device

Support is also available from your sales partner: 

www.sick.com

13.4 Copyright notices

Open source programs

SICK uses open-source software in the device. This software is licensed by the

rights holders using the following licenses among others: the free licenses GNU

General Public License (GPL Version2, GPL Version3) and GNU Lesser General

Public License (LGPL), the MIT license, zLib license, and the licenses derived from

the BSD license.
This program is provided for general use, but WITHOUT ANY WARRANTY OF ANY

KIND. This warranty disclaimer also extends to the implicit assurance of mar‐

ketability or suitability of the program for a particular purpose.
More details can be found in the GNU General Public License.
View the complete license texts here: 

www.sick.com/licensetexts

Printed copies of the license texts are also available on request.

8023832//2019-04-15/en

RFU610 | SICK

6

Reviews: