background image

Quick‐

start

Q U I C K S T A R T

e n

1

About this document

The purpose of this Quickstart is to allow you to commission the RFU610-106xx

RFID read/write device (UHF) quickly and easily and to achieve initial read results

with transponders.
The Quickstart is valid for the regional variants listed in the “Device overview” sec‐

tion: 

see Device overview, page 6

.

The Quickstart describes the commissioning process for an application with an

RFU610-106xx in an ambient temperature range of 0 °C to +50 °C.
Device variant RFU610-10600 (Ethernet variant, regional assignment: Europe) is

used as the basis for the examples given, based on its default. The optional

GL6 photoelectric sensor (1059241) is used as an example for the industrial-

standard read-cycle triggering of the RFU610-106xx. The photoelectric sensor can

be connected with the RFU610-106xx as a trigger sensor. Additional trigger sen‐

sors can be found a

www.sick.com

.

All rights reserved. Subject to change without notice.

2

Safety information

This chapter is dedicated to the safety of commissioning personnel and the

operator of the system in which the device is integrated.

Read this Quickstart carefully before commissioning the device in order to

familiarize yourself with the device and its functions. The Quickstart is con‐

sidered a part of the device and must be kept in an accessible location in

the immediate vicinity of the device at all times!

For country-specific particulars to consider when operating the device

see

Operational restrictions, page 6

.

WARNING

Health hazard as a result of high-frequency electromagnetic radiation!
The 

RFU610-10600

 (region: Europe) is designed for operation in accordance

with ETSI EN 302208. During operation, the human exposure regulations cov‐

ered by EN 50364 must be observed.

Limit human exposure to electromagnetic fields. Suitable safety dis‐

tances must be maintained during both short-term and long-term work

in the radiation range of the integrated antenna. Minimum distances to

be maintained between the antenna and the human body during long-

term transmission: 10 cm and maximum radiation power of the antenna

of 100 mW (20 dBm) as per ETSI.

The 

RFU610-10601

 (region: USA/Canada/Mexico) satisfies the limit values of

the FCC for exposure to radiation in an uncontrolled environment.

During operation, a safety distance of at least 20 cm must be main‐

tained between the antenna and the human body.

To comply with the IP67 enclosure rating in operation, the following require‐

ments must be met. If these requirements are not met, the device does not

fulfill any specified IP enclosure rating.

°

The side cover of the USB female connector and the microSD memory

card slot must be screwed tight to the device.

°

The SICK cables plugged into the M12 and M8 connections must be

screwed tight.

°

Any electrical connections that are not being used must be fitted with

protective caps or plugs that are screwed tight (as in the delivery condi‐

tion).

°

Only operate the device without a cover for a short period while insert‐

ing or removing the memory card or temporarily using the USB inter‐

face. During this time, protect the device against moisture and dust.

The type label on the lower side of the device contains a pressure equalizing

membrane. If damaged, water and dust leaks could occur.

Opening the screws of the device housing will invalidate any warranty claims

against SICK AG. For further warranty provisions, see the General Terms and

Conditions of SICK AG, e.g., on the delivery note of the device.

NOTE

SICK uses standard IP technology in its products. The emphasis is

placed on availability of products and services.
SICK always assumes the following prerequisites:

The customer ensures the integrity and confidentiality of the data

and rights affected by its own use of the aforementioned products.

In all cases, the customer implements the appropriate security

measures, such

 

as network separation, firewalls, virus protection,

and patch management.

2.1 Intended use

The RFU610-106xx is an intelligent UHF read/write device from the RFU61x prod‐

uct family. The device is used for the automated, fixed identification of passive,

wireless-based data cards (transponders) on moving or stationary objects and

their management.
As a compact read/write device, the RFU610-106xx has an internal antenna that

is integrated into the housing. The device processes all standard passive

transponders in accordance with ISO/IEC 18000-63 and EPCglobal UHF C1G2 in

the regional UHF carrier frequency range. Thanks to its intelligent process logic,

the device can be used either as a stand-alone solution or as part of a group in a

network. The device sends the read results to a higher-level computer for further

processing via its host interface. The device also receives commands for data

card management (write, read, etc.) via this interface.

3

Device description

3.1 Device view

9

2

 (

3

.6

2

)

1

9

8

94

 

(

3.70

)

106.4

 

(

4.19

)

R

e

ad

y

R

F

L

ink/A

c

t

m

ic

ro

S

D

4

0

 (

1

.5

7

)

1

6

(

0

.6

3

)

36

 (1.42)

â

80

 

(

3.15

)

38

 (1.50)

1

2

(0

.4

7

)

71

 

(

2.80

)

40

 

(

1.57

)

5

(0

.2

0

)

6.4

(0.25)

17.5

(0.69)

78.8

 

(

3.10

)

1

3

2

91

°

3

 (

0

.1

2

)

1

1

.5

 (

0

.4

5

)

9

.5

 (

0

.3

7

)

2

1

4

3

2 3

4

5

ß

á à

6

7

17.5

(0.69)

Figure 1: Dimensional drawing of the RFU610-106xx (all variants), unit: mm

(inch), decimal separator: period

1

Port 1: Power (male connector, M12, 4-pin, A-coded)

2

Port 3: Trigger (female connector, M8, 4-pin, A-coded)

3

Port 2: PoE (female connector, M12, 8-pin, X-coded)

4

Slot for microSD memory card

5

“USB” connection (female connector, 5-pin, type Micro-B) interface for

temporary use (service)

6

Side type label

7

Cover with integrated antenna

8

4 x multi-colored LED (status)

9

4 x RGB LED (process feedback)

ß

2 x M5 blind tapped holes, 6 mm deep for attaching the mounting

straps

à

2 x M5 blind tapped holes, 7 mm deep for mounting the device

á

Type label with integrated pressure compensation membrane

â

2 x screw (M2,5 socket screw), captive, for side cover

3.2 Status displays

m

ic

ro

S

D

R

F

R

e

a

d

y

L

in

k

/A

c

t

Status displays

Advertisement LED

Color

Status

Ready

Lights up

Green

Device ready

Lights up

Red

Hardware error

Flashing

Green

Flashing cyclically 4 x red, 1 x green in PROFINET

operation (single port): Trying to establish a con‐

nection to a PLC (IO controller) or loss of connec‐

tion during operation

Flashing

Red

RF

Lights up

Green

UHF field activated

Lights up

Red

Internal antenna fault / HF part

Link/Act

Lights up

Green

Data traffic via Ethernet

microSD

Lights up

Green

MicroSD memory card inserted and ready for

operation. In this state, the device can either

read data from the card or write data to the card.

If the LED lights up, however, this does not indi‐

cate that the device is accessing the card!

Lights up

Red

MicroSD memory card inserted; however, it can‐

not be read or is defective

8023832//2019-04-15/en

RFU610 | SICK

1

8023832//2019-04-15

www.sick.com

RFU610

SICK AG

Erwin-Sick-Straße 1

D-79183 Waldkirch

Reviews: