Operating instructions
Chapter
6
RFID Access Management
8018582/2015-11-03
Operating instructions| SICK
63
Subject to change without notice
Commissioning RFID Access
Management
Configuring the duration of the switching operation
In the
Switch output duration
field, specify how long the output should be activated for in
the event of a positive read result. The time is measured in milliseconds.
Completing the RFID interrogator entry
1. Click the
Find Me!
button and get an employee at the access point to confirm whether
the RFID interrogator is addressed correctly by RFID Access Management.
2. To finish the RFID interrogator entry, click
Save
. The RFID interrogator is configured
and added to the list of access points.
6.10.3
The access points in the System Overview
The top section of the System Overview shows all recorded access points.
The access points are listed with their name and an image of the device type used.
The connection type of the access point is also displayed for each device. This allows you
to quickly identify which devices are permanently accessible to the configuration PC
(
Permanent
connection type) and can be configured automatically, and which can only
be managed manually via a direct connection between the RFID interrogator and
configuration PC (
Temporary
connection type).
The status LEDs and the accompanying text provide information on the update status.
Here, for example, you can read whether all device parameters and the access
authorizations recorded in RFID Access Management have been transferred to the
respective access points. Further information can be found in chapter
update status of the access points
The configuration device is listed at the bottom of the window.
This section can also be used later on to determine how many persons and vehicles
have been recorded as participants and how many tags are registered in RFID Access
Management.