O P E R A T I N G   I N S T R U C T I O N S    

PGT-10-S  

 

Display Programming 

Tool 

 

 

SICK STEGMANN GmbH  

Dürrheimer Str. 36 
D-78166 Donaueschingen • www.sick.com 
8014529/2011-11-03

 

• KE 

Printed in Thailand (2011-11) • All rights reserved • 
Product features and technical data mentioned do not 
constitute a guarantee of any nature. 

 

1

 

About this document 

Please read these operating instructions carefully before 
using the PGT-10-S. 

1.1

 

Purpose of this document 

These operating instructions are for guiding the technical 
personnel of the machine manufacturer or machine 
operator in the commissioning and operation of the  

PGT-10-S. 

1.2

 

Symbols used 

 

Safety note! 

A safety note indicates a specific 
or potential hazard. It is for 
protecting you from accidents or 
any harm. 
Read the safety instructions 
carefully and follow them. 

 

 

Note on disposal! 

Please pay special attention to 
the notes on disposal. 

 

1.3

 

Associated documents 

 

VFS60 data sheet EN, part no. 8012074 

 

DFS60 data sheet EN, part no. 8012072 

 

DFV60 data sheet EN, part no. 8013656 

1.4

 

Maintenance and repair 

The PGT-10-S is maintenance-free. It is not designed to 
be repaired in the event of a defect. 

1.5

 

Disposal 

 

Always dispose of unusable devices in accordance with 
the applicable specific national waste disposal 
regulations. 

 

Your PGT-10-S uses long-life batteries.  
Should replacing them be necessary, please refer to 
"4.1 Inserting/replacing the batteries". 

 

Battery disposal! 

Batteries must not be disposed 
of via normal household waste. 
Please consult your local waste 
authority. 

 

2

 

Product description 

The PGT-10-S is a programming tool that you can use  
to easily program programmable Sick encoders 
(see "9 Technical data").  
Programming can be done either at the office, in the 
Production department, or in outdoor areas. PC/laptop 
and a mains connection are not required. 
Programmable parameters are: 

 

Setting the zero pulse 

 

Number of lines per revolution 

 

Electrical interface 

 

Electrical zero pulse width 

 

Mechanical zero pulse width 

3

 

Scope of delivery 

 

1 x PGT-10-S stand-alone programming tool 

 

2 x alkaline type batteries, 1.5 V Mignon (AA)  

For ordering an adapter cable, see "Accessories". 
Please check the delivered parts upon receipt. Please 
make sure that the adapter cable matches the encoder. 

 

Safety note! 

Always use the adapter cable 
that matches the encoder (see 
"Accessories"). 
Programming an incremental 
encoder using the adapter cable 
for an absolute encoder can lead 
to the destruction of the 
incremental encoder. 

 

Accessories 

Encoder 
connection 

Adapter cable 

Part no. 

M12 

DSL-2D08-G0M5AC3

 

2046579 

M23 

DSL-3D08-G0M5AC3

 

2046580 

Cable outlet 

DSL-0D08-G0M5AC3

 

2061739 

4

 

Commissioning 

4.1

 

Inserting/replacing the batteries 

Please use only leak-free and mercury-free alkaline type 
batteries or the corresponding lithium battery pack. 

 

 

Safety note! 

You have to open the housing of 
the PGT-10-S to insert/replace 
the batteries. The electronic card 
is then exposed.  
Make sure you do not damage 
the electronic components and 
connections. 
Make sure ESD protection is 
observed. 

 

 

Battery disposal! 

Batteries must not be disposed 
of via normal household waste. 
Please consult your local waste 
authority. 

 

For the power supply, insert the enclosed batteries into 
the housing of the PGT-10-S: 

 

Undo the four screws on the rear side of the housing 
and open it. 

 

Insert the batteries into the battery holders. In doing so, 
make sure the polarity is correct. 

 

Close the housing and screw it back together again. 

Note 

Please do not tighten the screws too strong as the 
threads of the housing can be damaged and 
consequently the housing can not be screwed properly 
any more. 

Note 

Power is supplied to the encoder via the PGT-10-S during 
programming. 

4.2

 

Connection to the encoder 

 

Safety note! 

Always use the adapter cable 
that matches the encoder (see 
"Accessories"). 
Programming an incremental 

encoder using the adapter cable 
for an absolute encoder can lead 
to the destruction of the 
incremental encoder. 

 

 

Connect the cable for the PGT-10-S to the adapter 
cable. 

 

Connect the encoder with the adapter cable, or the 
stranded wires of the encoder with the spring clips. 

Note 

4.3

 

Switching the PGT-10-S on and off  

The PGT-10-S is switched on by pressing any random 
pushbutton. It will automatically switch off approx. one 
minute after a pushbutton was last pressed.  
The PGT-10-S can be switched off by pressing the ESC 
button in the Welcome Message (Menu 0). In order to 

return from any submenu to the Menu 0 please press Esc 
several times. 

Note 

Changes that were made for the parameter values but 
not stored with the 

Save Settings

 function will be lost 

when the PGT-10-S is switched off. 

5

 

Operating elements 

PGT-10-S

Sensor Intelligence.

Esc

Enter

a

b

c

d

e

f

g

 

 

(a) 

LC-Display with two lines of 16 characters 

(b) 

Standby-LED (lights up red when the PGT-10-S is 
ready for operation). 

(c) 

Communication-LED (lights up green when data 
is being transmitted from or to the encoder). 

(d) 

"Upwards" arrow pushbutton 

(e) 

Esc pushbutton (input acknowledgement, go 
back to main menu or switch off. Changed 
parameter values are temporarily stored in the 
PGT-10-S). 

(f) 

Enter pushbutton (input acknowledgement or go 
to the submenu). 

(g) 

"Downwards" arrow pushbutton 

The arrow pushbuttons   and   can be used to 

 

cyclically scroll upwards and downwards in the menu,  

 

choose between several parameter values, 

 

set parameter values  
(see "7 Description of operation"). 

 

6

 

Menu 

The programming of the encoder using the PGT-10-S is 
menu driven: 

PGT Standalone Welcome V1.x 

Command: Backlight 

1.1 

 

Backlight OFF/ON (Esc or Enter) 

Command: Read Type Label 

2.1 

 

Part Number xxxxxxx 

2.2 

 

Type xFx60x-xxxxxxxxx 

2.3 

 

Date Code xxxx-xxxx  
or xxxx-xxxxxxxxx 

2.4 

 

Number of Lines xxxxx 

2.5 

 

Electrical Interface xxx 

2.6 

 

Zero Pulse Electrical xxx 

2.7 

 

Zero Pulse Mechanical xxx° 

Command: Read Enc. Position 

 

3.1 

 

Encoder Position xxxxx (Turn Enc) 

E + P 

Command: Zero Pulse Teach 

 

4.1 

 

Zero Teach (Esc or Enter) 

E + P 

Command: Set Number of Lines 

 

5.1 

 

Set Number of Lines xxxxx 

E + P 

Command: Set El. Interface 

 

6.1 

 

Set Interface HTL 

W + P 

6.2 

 

Set Interface TTL 

W + P 

Command: Set Zero Pulse El. 

 

7.1 

 

Set Zero Pulse 90°el gtd AˆB 

W + P 

7.2 

 

Set Zero Pulse 180°el gated B 

W + P 

7.3 

 

Set Zero Pulse 180°el gated A 

W + P 

7.4 

 

Set Zero Pulse 270°el gtd A

ˇ

W + P 

Command: Set Zero PulseMech. 

 

8.1 

 

Set Zero Pulse Mechanical xxx°   

E + P 

Command: Save Settings 

 

9.1 

 

Store current settings (Enter) 

S  

10 

Command: Read Settings 

 

10.1 

 

Number of Lines xxxxx 

W + P 

10.2 

 

Electrical Interface xxx 

W + P 

10.3 

 

Zero Pulse Electrical xxx 

W + P 

10.4 

 

Zero Pulse Mechanical xxx° 

W + P 

11 

Command: Program All 

 

11.1 

 

Program stored settings (Enter) 

Legend 

A  Display of parameter value 
E  Enter/adjust a parameter value 
P  Program the encoder 
S   Save a set of parameters in the PGT-10-S 
W  Select from parameter values offered 

 

7

 

Description of operation 

General notes 

 

Pressing the Enter pushbutton in the main menu allows 
you to access every function in the associated 
submenu. 

 

Pressing the Enter pushbutton in the submenu allows 

you to execute the respective function and then go 
automatically back to the main menu. 

 

Pressing the Esc pushbutton allows you to go back to 
the main menu from every function in the submenu. 
Changed parameter values are temporarily stored in the 
PGT-10-S, however, the encoder will not be 
programmed. 

 

Done! OK.

: The acknowledgement message is displayed 

for one second each time after the encoder has been 
successfully programmed or a set of parameters has 
been stored in the PGT-10-S. 

 

N/A

: No parameter value/not activated 

(0) Welcome message 

(PGT Standalone Welcome V1.x) 

The welcome message shows details of the firmware 
version of the PGT-10-S. 

(1) Display lighting (Command: Backlight) 

The back light of the display is switched off by default. 
You can switch it on if required. 

Esc

:

 

Switch off display lighting. 

Enter: 

Switch on display lighting. 

(2) Encoder data and parameter values 
(Command: Read Type Label) 

The encoder data and the current parameter values of 

the connected up encoder are displayed (see "6 Menu"). 
Use the arrow pushbuttons   and   to scroll upwards 
and downwards in the list of parameter values. 

Enter

:

 

No function 

(3) Encoder position (Command: Read Enc. Position) 

The current encoder position is displayed. When the shaft 
of the encoder is turned, the change in position can be 
tracked. 

Enter

:

 

No function 

(4) Set zero pulse  
(Command: Zero Pulse Teach) 

The zero pulse is assigned to the current encoder 
position. 

Enter

:

 

The encoder is programmed with the current 
positional value as zero pulse. 

Note 

Only execute this function when the shaft of the encoder 
has come to a standstill. 
After the encoder has been programmed, the function 

Read Enc. Position

 must deliver the value 0 ±1. 

(5) Number of lines per revolution 

(Command: Set Number of Lines) 

The current number of lines for the encoder is displayed. 
You can change the number of lines by using the arrow 
pushbuttons   and  . 

Keep one arrow pushbutton 

pressed down to increase the increment for the number 
of lines.

 

The maximum number of lines depends on the encoder 
type: 

B

asic 

DFx60

B

-xxP or Mxxxxxx  1 - 10000 

A

dvanced

 

DFx60

A

-xxP or Mxxxxxx  1 - 65536 

A

dvanced

 

VFS60

A

-xx

P

xxxxxx 

1 - 65536 

Enter

:

 

The encoder is programmed with the set number 
of lines per revolution. 

(6) Electrical interface  
(Command: Set El. Interface)

 

Choose between interfaces TTL and HTL. 

Enter

:

 

The encoder is programmed with the electrical 
interface selected. 

 (7) Electrical zero pulse width 

(Command: Set Zero Pulse El.) 

Choose between the parameter values for the electrical 
zero pulse width displayed in the submenu. 

Enter

:

 

The encoder is programmed with the electrical 
zero pulse width selected. 

Note 

Only one zero pulse (electrical or mechanical) can be 
active. 

(8)  Mechanical zero pulse width 

(Command: Set Zero PulseMech.) 

The arrow pushbuttons   and   can be used to set 
values between 1° - 359° for the mechanical zero pulse 
width. 

Keep one arrow pushbutton pressed down to 

increase the increment of the zero pulse.

 

Enter

:

 

The encoder is programmed with the mechanical 
zero pulse width selected. 

Note 

Only one zero pulse (electrical or mechanical) can be 
active. 

(9) Save set of parameters (Command: Save Settings) 

The parameter values currently set in the functions are 
stored in the PGT-10-S as a set of parameters, even if you 
have exited the functions using the Esc pushbutton and 
the connected up encoder has not been programmed.  
You can then use the stored set of parameters to 
program one or more encoders. 

Enter

:

 

The set of parameters is stored in the PGT-10-S. 

Note 

The encoder is not programmed. 

(10) Display set of parameters  
(Command: Read Settings) 

The set of parameters stored in the PGT-10-S using the 

Save Settings

 function is displayed. Use the arrow 

pushbuttons   and   to scroll upwards and downwards 
in the list of parameter values. 

Enter

:

 

No function 

(11) Program all (Command: Program All) 

This function (clone function) can be used to program any 
number of encoders successively using the same set of 
parameters. Prior to this, you would have had to store  
the set of parameters in the PGT-10-S using the  

Save Settings

 function. 

Enter

:

 

The encoder is programmed with the set of 
parameters stored in the PGT-10-S. 

7.1

 

Single programming 

You need to program one, single encoder: 

Preparation 

 

Safety note! 

Always use the adapter cable 
that matches the encoder (see 

"Accessories"). 
Programming an incremental 
encoder using the adapter cable 
for an absolute encoder can lead 
to the destruction of the 
incremental encoder. 

 

 

Connect the encoder to be programmed to the  
PGT-10-S using the adapter cable. 

Transferring the parameter value 

 

Set the required parameter value in a function  
or select from the parameter values provided  
(see "7 Description of operation"). 

 

Press the Enter pushbutton to program the encoder 
with the current parameter value.  

When you have transferred all required parameter values, 
the encoder is completely programmed and ready for use. 
Alternatively: If you have stored a prepared set of 
parameters using the 

Save Settings

 function, then you 

can also program the encoder in one step using the 

Program All

 function. 

7.2

 

Multiprogramming 

You need to program several encoders with the same set 
of parameters (clone function): 

Note 

You can easily prepare multiprogramming, for example in 
the office. In order to prepare the set of parameters for 
multiprogramming, the PGT-10-S must always be 
connected to an encoder. 

Preparation 

 

Safety note! 

Always use the adapter cable 
that matches the encoder (see 
"Accessories"). 
Programming an incremental 
encoder using the adapter cable 
for an absolute encoder can lead 
to the destruction of the 

incremental encoder. 

 

 

Connect an encoder type to be programmed to the  
PGT-10-S using the adapter cable. 

 

Set all the preferences you need for the parameter 
values (functions (5) to (8)). The parameter values do 
not have to be programmed in the encoder (set 
parameter value and exit the submenu using the Esc 
pushbutton). 

 

Store the previously set parameter values in the  
PGT-10-S using the 

Save Settings

 function. 

 

You can use the 

Read Settings

 function to check the 

stored parameter values. 

Programming the encoder 

 

Connect the encoder to be programmed to the  
PGT-10-S. 

 

Program the connected up encoder using the  

Program All

 function. The set of parameters stored in 

the PGT-10-S is transferred to the encoder. 

 

You can use the 

Read Type Label

 function to check the 

parameter values programmed in the encoder. 

 

Disconnect the encoder from the adapter cable.  

The encoder is completely programmed and ready for 
use. 

Programming further encoders 

Repeat the steps under "Programming the encoder" for all 
required encoders of the same type. 

Note 

The set of parameters stored in the PGT-10-S remains 
unchanged until you execute the 

Save Settings

 function 

again with the changed parameter values. 

8

 

Error messages 

With all error messages, you can go back to the main 
menu by pressing the Esc pushbutton. 

Firmware check  
Unknown Encoder 

Firmware of encoder is outdated 
(older than V04 or date code 
1112) 

Battery is Low 
Please Replace 

Operating voltage 

 2.0 V,  

replace the batteries. 
Successful completion of the 
current programming task is still 

guaranteed. 

This Encoder is  
NOT 
programmable 

The connected encoder is not a 
programmable type. Please check 
type code 

xxx 
  Size ERROR ! 

 

Encoder not connected up 

 

Encoder defective 

 

Cable defective 

xxx 
  Crc ERROR ! 

Error in the data transmission, 
execute the function again. 

xxx 
  Shift ERROR ! 

Error in the data transmission, 
execute the function again.  

9

 

Technical data 

Dimensions 
(L x W x H) 

90 mm x 70 mm x 30 mm  
 

Weight 

185 g (incl. batteries) 

Cable 

600 mm (L); D-SUB 9-pin plug 

Protection class 

IP 40 

Display 

LCD; two lines of 16 characters 

Power supply 

2 x 1.5 V Mignon (AA) 

Programmable 
Sick encoders 

Encoders beginning with firmware 
V04 or date code 1111-0104: 

 

B

asic: DFx60

B

-xxP or Mxxxxxx 

 

A

dvanced: DFx60

A

-xxP or Mxxxxxx 

 

A

dvanced: VFS60

A

-xx

P

xxxxxx 

Operating 
temperature 

0 °C to +40 °C 

Storage 
temperature 

-20 °C to +85 °C 

 

 

GND

+Us

A

B

B

Z

A

Z

 

It is vital you make sure the correct polarity 
is observed when connecting the stranded 
wires of the encoder with the spring clips, 
and in particular with customer specific 
encoders. 