Operating Instructions
Chapter
6
CLX490
8009237/RB47/2007-08-03
©
SICK AG · Division Auto Ident · Germany · All rights reserved
6-21
Operation
6.5.4
Displaying and editing operating data
This function enables statistical operating data, which the CLX maintains in the form of coun-
ters during the reading procedure, to be displayed and reset.
The CLX does not output a reading result in this mode.
1.
Click
in the tool bar.
The CLX cancels the Reading mode and the "Device Ready" LED is extinguished. The
O
PERATING
D
ATA
dialog box appears (
).
2.
After checking/resetting the desired counters, click OK to confirm any changes made.
The CLX then returns to the Reading mode and the "Device Ready" LED lights up.
6.5.5
Reading diagnosis
Function of the
auxiliary interface
. In this mode, the CLX outputs the data contents of all
the bar codes that were read – including those that, according to the evaluation criteria,
were not read properly and were thus incorrect – together with the associated reading dia-
gnosis data via the auxiliary interface. The number of bar codes output can, therefore, be
higher than the number of those that were sent via the host interface in the reading result.
In the default setting, this mode is selected for the auxiliary interface.
shows the output format of the auxiliary interface.
In the default setting, the CLX doesn’t output any reading diagnosis data via the host inter-
face.
If the reading diagnosis is to remain inactive, this can be set via the A
UXILIARY
I
NTERFACE
tab.
1.
In the A
UXILIARY
I
NTERFACE
drop-down list, choose R
EAD
D
IAGNOSTICS
.
2.
Perform a download to the CLX by clicking
in the toolbar.
The D
OWNLOAD
P
ARAMETERS
dialog box is then displayed.
3.
Choose the P
ERMANENT
storage option in the dialog box.
Fig. 6-8:
CLV-Setup: "Operating Data" dialog box