Operating Instructions
Chapter
5
CLX490
8009237/RB47/2007-08-03
©
SICK AG · Division Auto Ident · Germany · All rights reserved
5-17
Electrical installation
"IN 0 to IN 4" switching inputs
If the Autofocus function is not used and the CLXs dynamic focus control function is to be
triggered by external sensors, the sensors are connected to the five "IN 0 to IN 4" inputs.
Together with the internal assignment table, these can be used to configure a maximum of
32 switching states for up to 8 distance configurations. The dynamic focus control function
is selected for all inputs by default.
Additional function IN 4:
The "IN 4" input can alternatively be used as an input for a belt increment signal or for the
reading pulse end. In this case, a maximum of 16 switching statuses can be used for dyna-
mic focus control.
shows the connections for the "IN 0 to IN 4" switching inputs.
shows
the pin assignment on the CLX and the terminal assignment in the AMV/S 60.
contains the characteristic data for these inputs.
shows
the input combinations based on the distance configurations.
¾
Connect the sensors as shown in
For connecting the host interface via the AMV/S60 Connection Module, see the Operating
Instructions for the
"AMV/S60 Connection Module"
(no. 8008296).
Fig. 5-5:
Connections of the "IN 0 to IN 4" switching inputs
IN X
IN GND
GND
GND
GND
OUT
2k6
1
Y
9
5
IN X
V
S
/ 24 V
(IN) GND
GND
1
Y
9
5
V
S
V
S
V
S
V
S
CLX
AMV60-011
AMS60-012, -013
Terminal assignment
Switch
PNP sensor
Pin and terminal assignment
for
IN X
see
V
S
= +18 to +30 V DC for CLX without heater, 24 V DC +20 % /–10 % for CLX with heater
T. 28
Z
T. 20
T. 37
Input
IN X
CLX "I/O" connection
Pin Y
AMV/S60
Terminal Z
N 0
Pin 6
T. 22
N 1
Pin 2
T. 23
N 2
Pin 7
T. 24
N 3
Pin 11
T. 25
N 4
Pin 12
T. 26
Table 5-18: Pin and terminal assignment for "IN 0 to IN 4" switching inputs