Chapter
5
Operating Instructions
Compact OMNI Scanner
5-12
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 237/0000/07-05-2002
Electrical installation
c) Connections with connector cover no. 2 021 267
¾
Cover the "Host/Term" and "I/O" connections on the CLX with the connector cover
no. 2 020 267 and connect the free cable ends accordingly. The wire color assign-
ments are shown in
and
CLX with heater:
The connector cover can be used with temperatures up to max. –50
°
C if the CLX is station-
ary and the cables are not moved. If the cables are moved due to changes in the position
of the CLX, the temperature must not drop below max. –40
°
C.
Cable 1 (power supply)
15-pin D Sub HD socket in the connector cover and open cable end
Cable 2 (data and function interfaces)
15-pin D Sub HD socket/plug in the connector cover and open cable end
Pin
Plug cover
Signal
Wire color
1
Socket
V
S
Red
5
Socket
GND
Black
Table 5-14: Wire color assignment cable 1 for connector cover no. 2 021 267
Pin
Plug cover
Signal
Wire color
2
Plug
IN 1
White
3
Plug
Sensor
Brown
4
Plug
Result 1
Green
6
Plug
IN 0
Yellow
7
Plug
IN 2
Grey
8
Plug
Result 2
Pink
9
Plug
INGND
Blue
10
Plug
Result 3
Red
11
Plug
IN 3
Black
12
Plug
IN 4
Violet
15
Plug
Result 4
Grey-pink
2
Socket
RxD (RS 232), Terminal
Red-blue
3
Socket
TxD (RS 232), Terminal
White-green
4
Socket
Term (RS 422/485)
Brown-green
6
Socket
RD+ (RS 422/485), Host
White-yellow
7
Socket
RD– (RS 422/485), Host
RxD (RS 232), Host
Yellow-brown
8
Socket
TD+ (RS 422/485), Host
White-grey
9
Socket
TD– (RS 422/485), Host
TxD (RS 232), Host
Grey-brown
–
–
Shield
Orange
Table 5-15: Wire color assignment cable 2 for connector cover no. 2 021 267