10.10 Special applications and procedures
10.10.1 Auxiliary input
If the CLX cannot read a bar code in Reading mode (e. g. if there is no bar code on the ob-
ject), the data content of the bar code can be sent subsequently to the host by using the
"Auxiliary input" function. In this way, the sequence of reading results can be completed if
necessary.
The auxiliary input function uses the terminal interface of the CLX exclusively and features
two options:
•
manual entry of the data content on the keyboard of a connected terminal or PC
(Terminal Emulation function)
•
entry of the bar code using a hand-held reader. The data is then forwarded to the CLX
via an internal or external decoder
shows the basic auxiliary input principle.
The CLX sends the data content of the bar code that it receives via the terminal interface to
the host in the same format as the other reading results on the host interface. Each string
can contain the data from a bar code with a maximum length of 50 characters. The CLX au-
tomatically enters the status ST = 7 if the error status has been enabled for transmission.
The values of the other reading diagnosis data in the data string do not have any signifi-
cance.
To enable the CLX to receive the data content of the bar code on the terminal interface, you
must switch the operating mode on the interface to auxiliary input .
1.
Connect the PC to the
terminal interface
on the CLX using an RS 232 cable
(AMV/S 60: connect the PC to the internal 9-pin "Service" plug).
Chapter 5.5.6 Connecting the PC, Page 5-15
.
2.
Start CLV-Setup on your PC.
Chapter 10.6.3 Starting CLV-Setup, Page 10-17
3.
Choose the A
UXILIARY
I
NTERFACE
tab.
4.
Choose the A
UXILIARY
I
NPUT
option from the drop-down list.
5.
Download the changes to the CLX by clicking
in the toolbar .
The D
OWNLOAD
P
ARAMETERS
dialog box is then displayed.
6.
Confirm the dialog box by choosing the T
EMPORARY
storage option.
The terminal interface then operates temporarily in "Auxiliary input" mode.
Fig. 10-15: Auxiliary input via the terminal interface of the CLX
Data co Status
ST = 7
Data contents