7.2.2
Operating elements
Table 9: Functions of the reset pushbutton
Hold down pushbut‐
ton for
Function
Status LED
Description
< 1 s
None
Unchanged
If the button is not
held for long enough,
the changes are not
applied
1 to 5 s
IP address is initial‐
ized (static IP)
Flashing orange
(slowly)
IP address is changed
to 192.168.0.100
5 to 10 s
IP address is changed
(DHCP)
Flashing green (slowly) IP address is obtained
and set to DHCP
> 10 sec
All settings are initial‐
ized
Flashing green
(quickly)
All settings are reset
to the factory settings
NOTE
■
To reset all settings to the factory settings, press the reset pushbutton.
The reset pushbutton is only accessible once the screw has been removed.
■
Always remove and store the screw together with the sealing ring.
■
Refit the screw and sealing ring.
■
Observe the maximum torque of 0.08 Nm
±
20%.
The IP67 enclosure rating is only ensured with a proper screw connection and intact
sealing ring.
Use the SOPASair web browser to configure the device. The UDP/IP interface is mainly
recommended for streaming the measured values.
7.3
Operation via web browser (SOPASair)
7.3.1
Determining the device IP address
The default IP address of the device is 192.168.0.100.
The device IP address can be verified and adjusted by a device-specific search in
SOPAS ET.
7.3.2
Connecting via the web browser
The following browsers are supported:
•
Internet Explorer (version 11 or higher)
•
Google Chrome (version 49 or higher)
1.
Start browser.
2.
Enter the device IP address.
✓
The SOPASair settings screen is displayed.
Logging in
The user must log in to edit the device settings. The button is located at the bottom left
in the settings screen (person icon).
7
OPERATION
32
O P E R A T I N G I N S T R U C T I O N S | OD5000
8021391/17Y6/2020-05-11 | SICK
Subject to change without notice